The Effect of Photon Energy Weighting on X-ray Imaging Based on a Photon Counting Detector

被引:5
|
作者
Choi, Yu-Na
Lee, Seung-Wan
Cho, Hyo-Min
Ryu, Hyun-Ju
Lee, Young-Jin
Kim, Hee-Joung [1 ]
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju 220710, South Korea
基金
新加坡国家研究基金会;
关键词
Photon energy weighting; GATE; CNR; MONTE-CARLO-SIMULATION; DIGITAL MAMMOGRAPHY; GATE; PLATFORM; PET; CT;
D O I
10.3938/jkps.59.3114
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Development of photon counting detectors with the ability of energy discrimination would provide additional information. These detectors could improve the contrast-to-noise ratio (CNR) by using photon energy weighting with energy-dependent weighting factors. The purpose of this study was to evaluate the effect of photon energy weighting using GEANT4 Application for Tomographic Emission (GATE) version 6.0. The photon energy weighting depends on the X-ray attenuation coefficient of contrast elements and background materials. In this study, we simulated a photon counting X-ray imaging system. We designed a cadmium telluride (CdTe) photon counting detector (model PID-350, AJAT, Finland), the micro focus X-ray source (model L8601-01, Hamamatsu, Japan) and two phantoms with GATE. In the first case, we were concerned with calcifications in breast tissue or soft tissue. We defined a cubic phantom made of poly (methyl methacrylate) (PMMA) material with a thickness of 40 mm including four CaCO3 contrast elements with different thickness of 1.0, 3.0, 5.0, and 7.0 mm. In the second case, we designed a second phantom for contrast-enhanced digital mammography (CEDM). We defined two cylindrical phantoms made of PMMA with thicknesses of 30 and 40 mm, including four iodine contrast elements with different thicknesses of 0.3, 0.5, 1.0, and 1.5 mm. The effect of photon energy weighting was investigated in terms of the CNR. In all cases, photon energy weighting improve the CNR. The CNR improvements for CaCO3 with thicknesses of 1.0, 3.0, 5.0, and 7.0 mm were 1.41, 1.32, 1.43, and 1.56, respectively. For the second phantom with a thickness of 30 mm, the CNR improvements of iodine contrast elements with thicknesses of 1.0, 3.0, 5.0, and 7.0 mm were 1.01, 1.03, 1.09, and 1.13, respectively, and for the second phantom with a thicknesses of 40 mm, the CNR improvements of iodine contrast elements with thickness of 1.0, 3.0, 5.0, and 7.0 mm were 1.05, 1.07, 1.16, and 1.10, respectively. This study demonstrates that the photon energy weighting using additional information improves the CNR, which allows better detection of calcium, a contrast agent or other contrast elements.
引用
收藏
页码:3114 / 3119
页数:6
相关论文
共 50 条
  • [21] Development of an energy-binned photon-counting detector for X-ray and gamma-ray imaging
    Ogawa, Koichi
    Kobayashi, Toru
    Kaibuki, Futoshi
    Yamakawa, Tsutomu
    Nagano, Tatsuya
    Hashimoto, Daisuke
    Nagaoka, Hideyuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 664 (01): : 29 - 37
  • [22] Evaluation of a photon counting X-ray imaging detector based on Microchannel Plates for mammography applications
    Shikhaliev, PM
    Xu, T
    Molloi, S
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 726 - 733
  • [23] Energy-sensitive photon counting detector-based X-ray computed tomography
    Taguchi K.
    Radiological Physics and Technology, 2017, 10 (1) : 8 - 22
  • [24] Energy Weighting in a 2D-MHSP x-ray Single Photon Detector
    Oliveira, C. A. B.
    Santos, C. A.
    Silva, A. L. M.
    Dos Santos, J. M. F.
    Veloso, J. F. C. A.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3261 - +
  • [25] Energy Weighting in a 2D-MHSP X-Ray Single Photon Detector
    Oliveira, C. A. B.
    Santos, C. A.
    Carramate, L. F.
    Silva, A. L. M.
    da Luz, Natal
    dos Santos, J. M. F.
    Veloso, J. F. C. A.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (03) : 938 - 943
  • [26] Evaluation and comparison of a CdTe based photon counting detector with an energy integrating detector for X-ray phase sensitive imaging of breast cancer
    Ghani, Muhammad U.
    Omoumi, Farid H.
    Wu, Xizeng
    Fajardo, Laurie L.
    Zheng, Bin
    Liu, Hong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (02) : 207 - 219
  • [27] Photon counting silicon X-ray pixel detector modules
    Seller, P
    Derbyshire, G
    Hall, G
    Iles, GM
    Jorden, A
    Murray, P
    Prydderch, ML
    Passmore, SM
    Smith, K
    Thomas, SL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (01): : 174 - 177
  • [28] Photon Counting X-ray CT System with a Semiconductor Detector
    Kowase, Kazuhiko
    Ogawa, Koichi
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3119 - 3123
  • [29] Single Photon Counting X-Ray Imaging System
    Lee, Seung Eun
    Kim, Sang Don
    COMPUTATIONAL INTELLIGENCE AND INTELLIGENT SYSTEMS, 2012, 316 : 617 - 620
  • [30] Eiger: a single-photon counting x-ray detector
    Johnson, I.
    Bergamaschi, A.
    Billich, H.
    Cartier, S.
    Dinapoli, R.
    Greiffenberg, D.
    Guizar-Sicairos, M.
    Henrich, B.
    Jungmann, J.
    Mezza, D.
    Mozzanica, A.
    Schmitt, B.
    Shi, X.
    Tinti, G.
    JOURNAL OF INSTRUMENTATION, 2014, 9