Accuracy of implant placement with a computer-aided fabricated surgical template with guided parallel pins: A pilot study

被引:14
|
作者
Chang, Rai-Jei [1 ]
Chen, Hui-Ling [2 ,4 ]
Huang, Liang-Gie [1 ]
Wong, Yong-Kie [3 ,4 ]
机构
[1] Taichung Vet Gen Hosp, Dept Stomatol, Div Endodont & Periodontol, Taichung, Taiwan
[2] Taichung Vet Gen Hosp, Dept Stomatol, Div Dent Implant, Taichung, Taiwan
[3] Chang Bing Show Chan Mem Hosp, Dept Dent, Div Oral & Maxillofacial Surg, Changhua, Taiwan
[4] Natl Yang Ming Univ, Sch Dent, Taipei, Taiwan
关键词
Accuracy; Computer-aided surgery; Dental implant; IN-VITRO; TECHNOLOGY APPLICATIONS; ORAL IMPLANTS; DENTISTRY; SURGERY; SUCCESS; IMAGES;
D O I
10.1016/j.jcma.2018.04.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A precise positioning for dental implant placement is important for further prosthesis fabrication and maintenance. Computer-aided surgery has been developed to transfer digitally planned implant positioning to the patient over the past decades. This study aimed to evaluate the accuracy of a computer-aided laboratory-fabricated surgical template. A further objective was to compare the accuracy between in vivo and in vitro groups. Methods: A total of 20 implants were placed in the posterior tooth region through the aid of surgical templates on 17 partially edentulous patients in the in vivo group. The surgical template was fabricated in laboratory after virtual implant planning was completed using computer software. In the in vitro group, the same procedures were performed on the models without placing fixture with the same templates used in surgery. Deviations of the implant access at the implant platform level and apical region, as well as the angle deviations between the virtual planning data and the surgical results, were measured using a follow-up Cone Beam Computerized Tomography (CBCT) investigation, and image fusion with planning data. Result: The median deviation at platform level, apex and angulation was 0.95 mm (0.3-1.3 mm), 1.35 mm (0.1-3.6 mm) and 3.92 degrees (0.44-11.66 degrees) respectively in the in vivo group; and 0.4 mm (0-1.0 mm), 0.65 mm (0.1-1.9 mm), 2.16 degrees (0.17-6.91) respectively in the in vitro group. The in vitro group displayed significantly less deviation (p < 0.05). Conclusion: The data from this study shows that computer-aided laboratory-fabricated template may be a reliable tool for implant placement. However, the clinical conditions seem to affect the accuracy of the template. Copyright (C) 2018, the Chinese Medical Association. Published by Elsevier Taiwan LLC.
引用
收藏
页码:970 / 976
页数:7
相关论文
共 50 条
  • [41] Accuracy of dental implant insertion by computer-aided navigation in minipigs.
    Meyer, U
    Bier, J
    Runte, C
    Fillies, T
    Meier, N
    Joos, U
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A473 - A473
  • [42] A semi-automatic computer-aided method for surgical template design
    Xiaojun Chen
    Lu Xu
    Yue Yang
    Jan Egger
    Scientific Reports, 6
  • [43] A novel stereolithographic surgical template in computer-aided implantology: Methods and applications
    Institute of Biomedical Manufacturing and Life Quality Engineering, Shanghai Jiao Tong University, Shanghai, China
    Dental Implantation and Technology, (175-187):
  • [44] Digital Evaluation of the Accuracy of Computer-Guided Dental Implant Placement: An In Vitro Study
    Kim, Seong-Min
    Son, Keunbada
    Kim, Duk-Yeon
    Lee, Kyu-Bok
    APPLIED SCIENCES-BASEL, 2019, 9 (16):
  • [45] Accuracy of dental implant placement with computer-guided surgery: a retrospective cohort study
    Ku, Jeong-Kui
    Lee, Junggon
    Lee, Hyo-Jung
    Yun, Pil-Young
    Kim, Young-Kyun
    BMC ORAL HEALTH, 2022, 22 (01)
  • [46] Accuracy of dental implant placement with computer-guided surgery: a retrospective cohort study
    Jeong-Kui Ku
    Junggon Lee
    Hyo-Jung Lee
    Pil-Young Yun
    Young-Kyun Kim
    BMC Oral Health, 22
  • [47] A semi-automatic computer-aided method for surgical template design
    Chen, Xiaojun
    Xu, Lu
    Yang, Yue
    Egger, Jan
    SCIENTIFIC REPORTS, 2016, 6
  • [48] Virtually guided alveolar ridge reduction combined with computer-aided implant placement for a bimaxillary implant-supported rehabilitation: A clinical report
    Beretta, Mario
    Poli, Pier Paolo
    Tansella, Sebastian
    Maiorana, Carlo
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (02): : 168 - 172
  • [49] Marginal accuracy of computer-aided design- and computer-aided manufacturing-fabricated full-arch zirconia restoration
    Juntavee, Niwut
    Sirisathit, Issarawas
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2018, 10 : 9 - 17
  • [50] Influence of Surgeon Experience on the Accuracy of Implant Placement via a Partially Computer-Guided Surgical Protocol
    Marei, Hesham F.
    Abdel-Hady, Adel
    Al-Khalifa, Khalifa
    Al-Mahalawy, Haytham
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (05) : 1173 - 1179