Accuracy of implant placement with a computer-aided fabricated surgical template with guided parallel pins: A pilot study

被引:14
|
作者
Chang, Rai-Jei [1 ]
Chen, Hui-Ling [2 ,4 ]
Huang, Liang-Gie [1 ]
Wong, Yong-Kie [3 ,4 ]
机构
[1] Taichung Vet Gen Hosp, Dept Stomatol, Div Endodont & Periodontol, Taichung, Taiwan
[2] Taichung Vet Gen Hosp, Dept Stomatol, Div Dent Implant, Taichung, Taiwan
[3] Chang Bing Show Chan Mem Hosp, Dept Dent, Div Oral & Maxillofacial Surg, Changhua, Taiwan
[4] Natl Yang Ming Univ, Sch Dent, Taipei, Taiwan
关键词
Accuracy; Computer-aided surgery; Dental implant; IN-VITRO; TECHNOLOGY APPLICATIONS; ORAL IMPLANTS; DENTISTRY; SURGERY; SUCCESS; IMAGES;
D O I
10.1016/j.jcma.2018.04.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A precise positioning for dental implant placement is important for further prosthesis fabrication and maintenance. Computer-aided surgery has been developed to transfer digitally planned implant positioning to the patient over the past decades. This study aimed to evaluate the accuracy of a computer-aided laboratory-fabricated surgical template. A further objective was to compare the accuracy between in vivo and in vitro groups. Methods: A total of 20 implants were placed in the posterior tooth region through the aid of surgical templates on 17 partially edentulous patients in the in vivo group. The surgical template was fabricated in laboratory after virtual implant planning was completed using computer software. In the in vitro group, the same procedures were performed on the models without placing fixture with the same templates used in surgery. Deviations of the implant access at the implant platform level and apical region, as well as the angle deviations between the virtual planning data and the surgical results, were measured using a follow-up Cone Beam Computerized Tomography (CBCT) investigation, and image fusion with planning data. Result: The median deviation at platform level, apex and angulation was 0.95 mm (0.3-1.3 mm), 1.35 mm (0.1-3.6 mm) and 3.92 degrees (0.44-11.66 degrees) respectively in the in vivo group; and 0.4 mm (0-1.0 mm), 0.65 mm (0.1-1.9 mm), 2.16 degrees (0.17-6.91) respectively in the in vitro group. The in vitro group displayed significantly less deviation (p < 0.05). Conclusion: The data from this study shows that computer-aided laboratory-fabricated template may be a reliable tool for implant placement. However, the clinical conditions seem to affect the accuracy of the template. Copyright (C) 2018, the Chinese Medical Association. Published by Elsevier Taiwan LLC.
引用
收藏
页码:970 / 976
页数:7
相关论文
共 50 条
  • [21] Computer-Aided Design/Computer-Aided Manufacturing Surgical Guidance for Placement of Dental Implants: Case Report
    Wong, Natalie Y.
    Huffer-Charchut, Heather
    Sarment, David P.
    IMPLANT DENTISTRY, 2007, 16 (02) : 123 - 130
  • [22] The accuracy of computer-aided design and manufacturing surgical-guide for infrazygomatic crest miniscrew placement
    Jariyapongpaiboon, Prajak
    Chartpitak, Jirawan
    Jitsaard, Jaturong
    APOS TRENDS IN ORTHODONTICS, 2021, 11 (01) : 48 - 55
  • [23] Accuracy and operation procedure of robotic computer-aided implant surgery
    Liu, Yitian
    Zheng, Qingqing
    Xu, Zonghe
    Lin, Yanjun
    Zhang, Sihui
    Huang, Wenxiu
    Chen, Jiang
    Wu, Dong
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [24] Evaluation of marginal accuracy of polyetheretherketone and zirconia copings fabricated using computer-aided design/computer-aided manufacturing technique: An in vitro study
    Jangade, Manish
    Sharma, Ranu
    Sudharson, Nishanth A.
    Jain, Raj
    Sahu, Shailendra Kumar
    Dani, Anurag
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2025, 25 (01): : 95 - 101
  • [25] Accuracy of the computer-aided surgical simulation (CASS) system in the treatment of patients with complex craniomaxillofacial deformity: A pilot study
    Xia, James J.
    Gateno, Jaime
    Teichgraeber, John F.
    Christensen, Andrew M.
    Lasky, Robert E.
    Lemoine, Jeremy J.
    Liebschner, Michael A. K.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (02) : 248 - 254
  • [26] Accuracy and stability of computer-aided customized lingual fixed retainer: a pilot study
    Seung-Hyun Kang
    Jae-Sung Kwon
    Chooryung Judi Chung
    Jung-Yul Cha
    Kee-Joon Lee
    Progress in Orthodontics, 23
  • [27] Accuracy and stability of computer-aided customized lingual fixed retainer: a pilot study
    Kang, Seung-Hyun
    Kwon, Jae-Sung
    Chung, Chooryung Judi
    Cha, Jung-Yul
    Lee, Kee-Joon
    PROGRESS IN ORTHODONTICS, 2022, 23 (01)
  • [28] Effect of pilot-guided implant placement concept on the accuracy of osteotomy preparation and implant placement
    Sharma, Shruti
    Tan, Emilie
    Tran, Britney
    Siow, Hui Y.
    Tafesse, Elshadaie
    Thong, Yoong H. J.
    Tan, Row J. M.
    Son, Jungwoo
    Todaro, Lisa
    Teo, Josephine
    Abduo, Jaafar
    JOURNAL OF ORAL SCIENCE, 2024, 66 (01) : 20 - 25
  • [29] 3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study
    Sigmar Schnutenhaus
    Cornelia Edelmann
    Heike Rudolph
    Jens Dreyhaupt
    Ralph G. Luthardt
    Clinical Oral Investigations, 2018, 22 : 2363 - 2372
  • [30] 3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study
    Schnutenhaus, Sigmar
    Edelmann, Cornelia
    Rudolph, Heike
    Dreyhaupt, Jens
    Luthardt, Ralph G.
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (06) : 2363 - 2372