Accuracy of implant placement with a computer-aided fabricated surgical template with guided parallel pins: A pilot study

被引:14
|
作者
Chang, Rai-Jei [1 ]
Chen, Hui-Ling [2 ,4 ]
Huang, Liang-Gie [1 ]
Wong, Yong-Kie [3 ,4 ]
机构
[1] Taichung Vet Gen Hosp, Dept Stomatol, Div Endodont & Periodontol, Taichung, Taiwan
[2] Taichung Vet Gen Hosp, Dept Stomatol, Div Dent Implant, Taichung, Taiwan
[3] Chang Bing Show Chan Mem Hosp, Dept Dent, Div Oral & Maxillofacial Surg, Changhua, Taiwan
[4] Natl Yang Ming Univ, Sch Dent, Taipei, Taiwan
关键词
Accuracy; Computer-aided surgery; Dental implant; IN-VITRO; TECHNOLOGY APPLICATIONS; ORAL IMPLANTS; DENTISTRY; SURGERY; SUCCESS; IMAGES;
D O I
10.1016/j.jcma.2018.04.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A precise positioning for dental implant placement is important for further prosthesis fabrication and maintenance. Computer-aided surgery has been developed to transfer digitally planned implant positioning to the patient over the past decades. This study aimed to evaluate the accuracy of a computer-aided laboratory-fabricated surgical template. A further objective was to compare the accuracy between in vivo and in vitro groups. Methods: A total of 20 implants were placed in the posterior tooth region through the aid of surgical templates on 17 partially edentulous patients in the in vivo group. The surgical template was fabricated in laboratory after virtual implant planning was completed using computer software. In the in vitro group, the same procedures were performed on the models without placing fixture with the same templates used in surgery. Deviations of the implant access at the implant platform level and apical region, as well as the angle deviations between the virtual planning data and the surgical results, were measured using a follow-up Cone Beam Computerized Tomography (CBCT) investigation, and image fusion with planning data. Result: The median deviation at platform level, apex and angulation was 0.95 mm (0.3-1.3 mm), 1.35 mm (0.1-3.6 mm) and 3.92 degrees (0.44-11.66 degrees) respectively in the in vivo group; and 0.4 mm (0-1.0 mm), 0.65 mm (0.1-1.9 mm), 2.16 degrees (0.17-6.91) respectively in the in vitro group. The in vitro group displayed significantly less deviation (p < 0.05). Conclusion: The data from this study shows that computer-aided laboratory-fabricated template may be a reliable tool for implant placement. However, the clinical conditions seem to affect the accuracy of the template. Copyright (C) 2018, the Chinese Medical Association. Published by Elsevier Taiwan LLC.
引用
收藏
页码:970 / 976
页数:7
相关论文
共 50 条
  • [31] Exploring Effectiveness of Computer-Aided Planning in Implant Positioning for a Single Immediate Implant Placement
    Edelmann, Alexander R.
    Hosseini, Bashir
    Byrd, Warren C.
    Preisser, John S.
    Tyndall, Donald A.
    Nguyen, Tung
    Bencharit, Sompop
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (03) : 233 - 239
  • [32] Accuracy of Two Stereolithographic Guide Systems for Computer-Aided Implant Placement: A Computed Tomography-Based Clinical Comparative Study
    Arisan, Volkan
    Karabuda, Z. Cuneyt
    Ozdemir, Tayfun
    JOURNAL OF PERIODONTOLOGY, 2010, 81 (01) : 43 - 51
  • [33] Accuracy of computer-guided implant placement in anterior regions
    Fang, Yiqin
    An, Xueyin
    Jeong, Seung-Mi
    Choi, Byung-Ho
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (05): : 836 - 842
  • [34] Computer-aided design/computer-aided manufacturing surgical guidance for placement of dental implants: case report.
    Wong, N. Y.
    Huffer-Charchut, H.
    Sarment, D.
    IMPLANT DENTISTRY, 2007, 16 (03) : 326 - 326
  • [35] Influence of the macrodesign of an implant and the sleeve system on the accuracy of template-guided implant placement: A prospective clinical study
    Schnutenhaus, Sigmar
    Edelmann, Cornelia
    Wetzel, Martin
    Luthardt, Ralph G.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (02): : 212 - 219
  • [36] Three-Dimensional Accuracy of Surgical Guides for Static Computer-Aided Implant Surgery: A Systematic Review
    Lo Russo, Lucio
    Pierluigi, Mariani
    Zhurakivska, Khrystyna
    Digregorio, Chiara
    Lo Muzio, Eleonora
    Laino, Luigi
    PROSTHESIS, 2023, 5 (03): : 809 - 825
  • [37] Computer-aided design and manufacturing construction of a surgical template for craniofacial implant positioning to support a definitive nasal prosthesis
    Ciocca, Leonardo
    Fantini, Massimiliano
    De Crescenzio, Francesca
    Persiani, Franco
    Scotti, Roberto
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (08) : 850 - 856
  • [38] A retrospective study of the accuracy of template-guided versus freehand implant placement: A nonradiologic method
    Alevizakos, Vasilios
    Mitov, Gergo
    Stoetzer, Marcus
    von See, Constantin
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2019, 128 (03): : 220 - 226
  • [39] The Accuracy of Zygomatic Implant Placement Assisted by Dynamic Computer-Aided Surgery: A Systematic Review and Meta-Analysis
    Fan, Shengchi
    Saenz-Ravello, Gustavo
    Diaz, Leonardo
    Wu, Yiqun
    Davo, Ruben
    Wang, Feng
    Magic, Marko
    Al-Nawas, Bilal
    Kaemmerer, Peer W.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (16)
  • [40] Complications of computer-aided-design/computer-aided-machining-guided (NobelGuide™) surgical implant placement:: An evaluation of early clinical results
    Yong, Loong Tee
    Moy, Peter K.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2008, 10 (03) : 123 - 127