Agreement and Repeatability of Corneal Thickness and Radius among Three Different Corneal Measurement Devices

被引:13
|
作者
Biswas, Sayantan [1 ,2 ]
Biswas, Partha [3 ]
机构
[1] Singapore Eye Res Inst, Visual Neurosci Res Grp, Singapore, Singapore
[2] MS Ramaiah Univ Appl Sci, Fac Life & Allied Hlth Sci, Dept Allied Hlth Sci, Bengaluru, Karnataka, India
[3] BB Eye Fdn, Kolkata, W Bengal, India
关键词
OPTICAL COHERENCE TOMOGRAPHY; ORBSCAN-II; TOPOGRAPHY; KERATOCONUS; PENTACAM; EYES; REPRODUCIBILITY; PACHYMETRY; CURVATURE; OCT;
D O I
10.1097/OPX.0000000000001785
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE Corneal refractive surgery screening, orthokeratology, and contact lens fitting require accurate estimation of the corneal thickness and curvature. We found that any of the imaging devices used in this study can be used to image a healthy myopic cornea, which is essential to screen for corneal ectasia. PURPOSE This study aimed to compare agreement and repeatability of corneal thickness and radius measurements obtained using Scheimpflug imaging (Pentacam HR), swept-source optical coherence tomography (Casia SS-1000), and Placido-Scheimpflug tomography (Topographic Modeling System, version 5 [TMS-5]). METHODS Sixty eyes of 60 subjects with myopia were measured with Casia, TMS-5, and Pentacam for their central corneal thickness (CCT), thinnest corneal thickness, central corneal radius of the steep meridian (Ks), central corneal radius of the flat meridian (Kf), mean central corneal radius (Km), and anterior and posterior best-fit spheres. Two readings were obtained from each instrument. Central corneal thickness was also measured with ultrasound pachymetry. Intraclass correlation coefficient, repeatability coefficient, and coefficient of variation were calculated. RESULTS Repeatability coefficient, coefficient of variation, and intraclass correlation coefficient of CCT among the instruments ranged between 2.48 and 12.79, 0.17 and 0.86, and 0.98 and 1.00, respectively. Mean CCT measurements were similar between Casia, TMS-5, Pentacam, and ultrasound pachymetry (P = .13). Intraclass range of correlation for agreement was 0.95 to 0.99 for CCT among instruments. The range of 95% limits of agreement (LoAs) for ultrasound CCT was narrowest with Casia (31.94 mu m). Casia-TMS-5 displayed a narrow range of 95% LoA for CCT (12.14 to -12.44), thinnest corneal thickness (12.31 to -11.31), and Ks (0.56 to -0.53), whereas Casia-Pentacam showed a narrow range of 95% LoA for Kf (0.56 to -0.42), Km (0.41 to -0.27), and anterior best-fit sphere (0.03 to -0.07). A significant difference in posterior best-fit sphere measurements was noted among all instruments (P = .01). CONCLUSIONS Casia, TMS-5, and Pentacam can be used interchangeably to measure corneal thickness and radius measurement in healthy eyes. Casia had the best agreement with ultrasound pachymeter CCT and exhibited the highest repeatability.
引用
收藏
页码:1196 / 1202
页数:7
相关论文
共 50 条
  • [41] Corneal thickness: measurement and implications
    Ehlers, N
    Hjortdal, J
    EXPERIMENTAL EYE RESEARCH, 2004, 78 (03) : 543 - 548
  • [42] OPTICAL MEASUREMENT OF CORNEAL THICKNESS
    EHLERS, N
    ACTA OPHTHALMOLOGICA, 1971, 49 (01): : 65 - &
  • [43] Repeatability and Agreement of 4 Biometers Measuring Corneal Astigmatism in Eyes With Irregular Corneal Astigmatism Component
    Wang, Lan
    Shao, Xu
    Fu, Jin-Ling
    Hu, Jing-Jing
    Zhou, Kai-Jing
    Li, Ran
    Yu, A-Yong
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 265 : 200 - 212
  • [44] Repeatability of Corneal Thickness Measured Using an Oculus Pentacam
    Miranda, Marco A.
    Radhakrishnan, Hema
    O'Donnell, Clare
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (03) : 266 - 272
  • [45] Repeatability of corneal and conjunctival sensitivity measurement.
    Stapleton, F
    Tan, ME
    Vega, J
    Papas, EB
    Belmonte, C
    Holden, BA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S338 - S338
  • [46] Comparison of Two Different Methods in Central Corneal Thickness Measurement
    Yaycioglu, Rana Altan
    Pelit, Aysel
    Toygar, Okan
    Akova, Yonca Aydin
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2006, 36 (04): : 306 - 310
  • [47] Central Corneal Thickness Measured With Three Optical Devices and Ultrasound Pachometry
    Gonzalez-Perez, Javier
    Manuel Gonzalez-Meijome, Jose
    Rodriguez Ares, Maria Teresa
    Angel Parafita, Manuel
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2011, 37 (02): : 66 - 70
  • [48] Central Corneal Thickness Measurements With Different Imaging Devices and Ultrasound Pachymetry
    Tai, Lai-Yong
    Khaw, Keat-Ween
    Ng, Choung-Min
    Subrayan, Visvaraja
    CORNEA, 2013, 32 (06) : 766 - 771
  • [49] Central Corneal Thickness Reproducibility among Ten Different Instruments
    Pierro, Luisa
    Iuliano, Lorenzo
    Gagliardi, Marco
    Ambrosi, Alessandro
    Rama, Paolo
    Bandello, Francesco
    OPTOMETRY AND VISION SCIENCE, 2016, 93 (11) : 1371 - 1379
  • [50] Repeatability of peripheral (near-limbal) corneal thickness measurements of Pentacam Scheimpflug corneal topography
    Martin, Raul
    Jonuscheit, Sven
    Doughty, Michael
    del Rio San Cristobal, Ana
    Mackintosh, Lisa
    MacTaggart, David
    Hiscock, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)