Effect of Scala Tympani Height on Insertion Depth of Straight Cochlear Implant Electrodes

被引:17
|
作者
Morrel, William G. [1 ]
Holder, Jourdan T. [2 ]
Dawant, Benoit M. [3 ]
Noble, Jack H. [3 ]
Labadie, Robert F. [1 ,4 ]
机构
[1] Vanderbilt Univ, Dept Otolaryngol, Med Ctr, 7209 Med Ctr East,South Tower, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Med Ctr, Dept Hearing & Speech Sci, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Elect Engn & Comp Sci, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37232 USA
关键词
cochlear implantation; scala tympani height; translocation; straight electrodes; HEARING; LENGTH; LOCALIZATION; LOCATION; IMPACT; DIMENSIONS; PLACEMENT; SPEECH;
D O I
10.1177/0194599820904941
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective Studies suggest lateral wall (LW) scala tympani (ST) height decreases apically, which may limit insertion depth. No studies have investigated the relationship of LW ST height with translocation rate or location. Study Design Retrospective review. Setting Cochlear implant program at tertiary referral center. Subjects and Methods LW ST height was measured in preoperative images for patients with straight electrodes. Scalar location, angle of insertion depth (AID), and translocation depth were measured in postoperative images. Audiologic outcomes were tracked. Results In total, 177 ears were identified with 39 translocations (22%). Median AID was 443 degrees (interquartile range [IQR], 367 degrees-550 degrees). Audiologic outcomes (126 ears) showed a small, significant correlation between consonant-nucleus-consonant (CNC) word score and AID (r = 0.20, P = .027), although correlation was insignificant if translocation occurred (r = 0.11, P = .553). Translocation did not affect CNC score (P = .335). AID was higher for translocated electrodes (503 degrees vs 445 degrees, P = .004). Median translocation depth was 381 degrees (IQR, 222 degrees-399 degrees). Median depth at which a 0.5-mm electrode would not fit within 0.1 mm of LW was 585 degrees (IQR, 405 degrees-585 degrees). Median depth at which a 0.5-mm electrode would displace the basilar membrane by >= 0.1 mm was 585 degrees (IQR, 518 degrees-765 degrees); this was defined as predicted translocation depth (PTD). Translocation rate was 39% for insertions deeper than PTD and 14% for insertions shallower than PTD (P = .008). Conclusion AID and CNC are directly correlated for straight electrodes when not translocated. Translocations generally occur around 380 degrees and are more common with deeper insertions due to decreasing LW ST height. Risk of translocation increases significantly after 580 degrees.
引用
收藏
页码:718 / 724
页数:7
相关论文
共 50 条
  • [21] Simulations of tonotopically mapped speech processors for cochlear implant electrodes varying in insertion depth
    Faulkner, A
    Rosen, S
    Stanton, D
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (02): : 1073 - 1080
  • [22] Simulations of tonotopically mapped speech processors for cochlear implant electrodes varying in insertion depth
    Faulkner, A. (andyf@phon.ucl.ac.uk), 1600, Acoustical Society of America (113):
  • [23] Potential insertion complications with cochlear implant electrodes
    Ishiyama, Akira
    Risi, Frank
    Boyd, Paul
    COCHLEAR IMPLANTS INTERNATIONAL, 2020, 21 (04) : 206 - 219
  • [24] The Use of Clinically Measurable Cochlear Parameters in Cochlear Implant Surgery as Indicators for Size, Shape, and Orientation of the Scala Tympani
    Schurzig, Daniel
    Timm, Max E.
    Majdani, Omid
    Lenarz, Thomas
    Rau, Thomas S.
    EAR AND HEARING, 2021, 42 (04): : 1034 - 1041
  • [25] Impact of the Insertion Speed of Cochlear Implant Electrodes on the Insertion Forces
    Kontorinis, Georgios
    Lenarz, Thomas
    Stoever, Timo
    Paasche, Gerrit
    OTOLOGY & NEUROTOLOGY, 2011, 32 (04) : 565 - 570
  • [26] The consequences of neural degeneration regarding optimal cochlear implant position in scala tympani: A model approach
    Briaire, Jeroen J.
    Frijns, Johan H. M.
    HEARING RESEARCH, 2006, 214 (1-2) : 17 - 27
  • [27] Optimal path generation in scala tympani and path planning for robotic cochlear implant of perimodiolar electrode
    Wang, Zuo
    Li, Jianjun
    Wu, Yongzhen
    Zhu, Ruifeng
    Wang, Binrui
    Zhao, Kai
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2020, 234 (06) : 578 - 589
  • [28] Cochlear Size Assessment Predicts Scala Tympani Volume and Electrode Insertion Force- Implications in Robotic Assisted Cochlear Implant Surgery (vol 8, 723897, 2021)
    Dhanasingh, Anandhan
    Swords, Chloe
    Bance, Manohar
    Van Rompaey, Vincent
    van de Heyning, Paul
    FRONTIERS IN SURGERY, 2021, 8
  • [29] Hearing results with deep insertion of cochlear implant electrodes
    Hodges, AV
    Villasuso, E
    Balkany, T
    Bird, PA
    Butts, S
    Lee, D
    Gomez, O
    AMERICAN JOURNAL OF OTOLOGY, 1999, 20 (01): : 53 - 55
  • [30] Force measurement at the insertion process of cochlear implant electrodes
    Majdani, Omid
    Kobler, Jan-Phillipp
    Beckmann, Daniel
    Ortmaier, Tobias
    Lenarz, Thomas
    Rau, Thomas
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 438 - 438