Effect of Scala Tympani Height on Insertion Depth of Straight Cochlear Implant Electrodes

被引:17
|
作者
Morrel, William G. [1 ]
Holder, Jourdan T. [2 ]
Dawant, Benoit M. [3 ]
Noble, Jack H. [3 ]
Labadie, Robert F. [1 ,4 ]
机构
[1] Vanderbilt Univ, Dept Otolaryngol, Med Ctr, 7209 Med Ctr East,South Tower, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Med Ctr, Dept Hearing & Speech Sci, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Elect Engn & Comp Sci, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37232 USA
关键词
cochlear implantation; scala tympani height; translocation; straight electrodes; HEARING; LENGTH; LOCALIZATION; LOCATION; IMPACT; DIMENSIONS; PLACEMENT; SPEECH;
D O I
10.1177/0194599820904941
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective Studies suggest lateral wall (LW) scala tympani (ST) height decreases apically, which may limit insertion depth. No studies have investigated the relationship of LW ST height with translocation rate or location. Study Design Retrospective review. Setting Cochlear implant program at tertiary referral center. Subjects and Methods LW ST height was measured in preoperative images for patients with straight electrodes. Scalar location, angle of insertion depth (AID), and translocation depth were measured in postoperative images. Audiologic outcomes were tracked. Results In total, 177 ears were identified with 39 translocations (22%). Median AID was 443 degrees (interquartile range [IQR], 367 degrees-550 degrees). Audiologic outcomes (126 ears) showed a small, significant correlation between consonant-nucleus-consonant (CNC) word score and AID (r = 0.20, P = .027), although correlation was insignificant if translocation occurred (r = 0.11, P = .553). Translocation did not affect CNC score (P = .335). AID was higher for translocated electrodes (503 degrees vs 445 degrees, P = .004). Median translocation depth was 381 degrees (IQR, 222 degrees-399 degrees). Median depth at which a 0.5-mm electrode would not fit within 0.1 mm of LW was 585 degrees (IQR, 405 degrees-585 degrees). Median depth at which a 0.5-mm electrode would displace the basilar membrane by >= 0.1 mm was 585 degrees (IQR, 518 degrees-765 degrees); this was defined as predicted translocation depth (PTD). Translocation rate was 39% for insertions deeper than PTD and 14% for insertions shallower than PTD (P = .008). Conclusion AID and CNC are directly correlated for straight electrodes when not translocated. Translocations generally occur around 380 degrees and are more common with deeper insertions due to decreasing LW ST height. Risk of translocation increases significantly after 580 degrees.
引用
收藏
页码:718 / 724
页数:7
相关论文
共 50 条
  • [31] Insertion Depth of the Cochlear Implant - Individual Assesment required
    Laszig, R.
    HNO, 2017, 65 (09) : 710 - 711
  • [32] Standardization of CT Depiction of Cochlear Implant Insertion Depth
    Colby, C. C.
    Todd, N. W.
    Harnsberger, H. R.
    Hudgins, P. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (02) : 368 - 371
  • [33] The effect of simulated insertion depth differences on the vocal pitches of cochlear implant users
    Soleimanifar, Simin
    Staisloff, Hannah E.
    Aronoff, Justin M.
    JASA EXPRESS LETTERS, 2022, 2 (04):
  • [34] Simulating the effect of cochlear-implant electrode insertion depth on speech understanding
    Dorman, MF
    Loizou, PC
    Rainey, D
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (05): : 2993 - 2996
  • [35] Factors Affecting Outcomes in Cochlear Implant Recipients Implanted With a Perimodiolar Electrode Array Located in Scala Tympani
    Holden, Laura K.
    Firszt, Jill B.
    Reeder, Ruth M.
    Uchanski, Rosalie M.
    Dwyer, Noel Y.
    Holden, Timothy A.
    OTOLOGY & NEUROTOLOGY, 2016, 37 (10) : 1662 - 1668
  • [36] Assessing Cochlear Implant Insertion Angle From an Intraoperative X-ray Using a Rotating 3D Helical Scala Tympani Model
    Giardina, Christopher K.
    Canfarotta, Michael W.
    Thompson, Nicholas J.
    Fitzpatrick, Douglas C.
    Hodge, Sarah E.
    Baker, Jenna
    O'Connell, Brendan P.
    OTOLOGY & NEUROTOLOGY, 2020, 41 (06) : E686 - E694
  • [37] Simultaneous Bilateral Cochlear Implantation in an Adult with Bilateral Ossification of the Scala Tympani: Image-Guided Planning of Scala Vestibuli Insertion and Postoperative Outcomes
    De Bie, Charlotte
    Clement, Charis
    Mertens, Griet
    Brandt, Anouk Hofkens-Van den
    Lammers, Marc
    Vanderveken, Olivier M.
    Van Rompaey, Vincent
    B-ENT, 2024, 20 (04)
  • [38] Round Window Membrane Insertion With Perimodiolar Cochlear Implant Electrodes
    Coordes, Annekatrin
    Ernst, Arne
    Brademann, Goetz
    Todt, Ingo
    OTOLOGY & NEUROTOLOGY, 2013, 34 (06) : 1027 - 1032
  • [39] Extrusion of straight cochlear implant electrodes May be diminished by proximal fixation
    Zawawi, Faisal
    Cushing, Sharon L.
    James, Adrian L.
    Gordon, Karen A.
    Papsin, Blake C.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2019, 116 : 164 - 167
  • [40] In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays
    Ketten, DR
    Vannier, MW
    Skinner, MW
    Gates, GA
    Wang, G
    Neely, JG
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1998, 107 (11): : 1 - 16