Phasic coronary blood flow pattern during a continuous flow left ventricular assist support

被引:34
|
作者
Ootaki, Y [1 ]
Kamohara, K [1 ]
Akiyama, M [1 ]
Zahr, F [1 ]
Kopcak, MW [1 ]
Dessoffy, R [1 ]
Fukamachi, K [1 ]
机构
[1] Cleveland Clin Fdn, Lerner Res Int, Dept Biomed Engn, Cleveland, OH 44195 USA
关键词
circulatory assistance; left ventricular assist device; perfusion;
D O I
10.1016/j.ejcts.2005.08.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Continuous flow left ventricular assist devices (LVADs) have been introduced and tested as a bridge to heart transplantation, bridge to recovery, and destination therapy, and several studies have been conducted to assess the physiologic effects of continuous flow LVADs. However, the effect of reduced pulsatility on the phasic coronary blood flow pattern is unknown. The aim of this study was to investigate the phasic coronary blood flow patterns during continuous flow LVAD support. Methods: Phasic coronary blood flow patterns and hemodynamic data were analyzed using three flow probes placed around the left anterior descending coronary artery (LAD), Left circumflex coronary artery (LCX), and the right coronary artery (RCA) in 16 pigs before and after initiating the LVAD support with or without creating LAD stenosis. Results: The total coronary blood flow (TCBF, 112.8 +/- 31.4 mL/min) gradually decreased when the continuous flow LVAD support increased to 2.0 L/min (110.7 +/- 29.0 mL/min, P = 0.571), 2.5 L/min (103.7 +/- 26.1 mL/min, P = 0.079), and 3.0 L/min (101.5 +/- 27.2 mL/min, P = 0.027) because of decreases in LAD flow and LCX flow. LVAD support caused decrease in systolic and peak systolic LAD flow, LCX flow, and RCA flow, whereas diastolic RCA flow increased. In the presence of LAD stenosis, the TCBF (97.7 +/- 36.1 mL/min) decreased when the continuous flow LVAD support increased to 2.0 L/min (83.9 +/- 22.1 mL/min, P = 0.029), 2.5 L/min (83.2 +/- 25.2 mL/min, P = 0.012), and 3.0 L/min (87.6 +/- 23.4 mL/min, P = 0.005) because of decreases in LCX flow. Conclusion: Use of a continuous flow LVAD decreased TCBF, LAD flow, and LCX flow secondary to reduced systotic LAD flow and LCX flow, and decreased TCBF and LCX flow in the presence of LAD stenosis. These findings are potentially relevant to understanding the physiology of myocardial blood perfusion during continuous flow LVAD support especially in patients with coronary artery disease. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:711 / 716
页数:6
相关论文
共 50 条
  • [31] Carotid Artery Blood Flow and Its Association with Stroke during Left Ventricular Assist Device Support
    Kiyatkin, M. E.
    Zuver, A. M.
    Gaudig, A.
    Tiburcio, M.
    McDonnell, B. J.
    Yuzefpolskaya, M.
    Colombo, P. C.
    Stohr, E. J.
    Willey, J. Z.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S171 - S171
  • [32] Impact of turbulent blood flow in the aortic root on de novo aortic insufficiency during continuous-flow left ventricular-assist device support
    Yoshida, Shohei
    Toda, Koichi
    Miyagawa, Shigeru
    Yoshikawa, Yasushi
    Hata, Hiroki
    Yoshioka, Daisuke
    Kainuma, Satoshi
    Kawamura, Takuji
    Kawamura, Ai
    Nakatani, Satoshi
    Sawa, Yoshiki
    ARTIFICIAL ORGANS, 2020, 44 (08) : 883 - 891
  • [33] Effects of hemopump support on left ventricular unloading and coronary blood flow
    Shiya, Norihiko
    Zelinsky, Robin
    Deleuze, Philippe H.
    Loisance, Daniel Y.
    ASAIO Transactions, 1991, 37 (03):
  • [34] Hemodynamic Assessment in Patients on Chronic Continuous Flow Left Ventricular Assist Device Support
    Hasin, T.
    Schettle, S. D.
    Nativi-Nicolau, J.
    Park, S. J.
    Borlaug, B. A.
    Pereira, N. L.
    Edwards, B. S.
    Clavell, A. L.
    Joyce, L. D.
    Stulak, J. M.
    Daly, R. C.
    Kushwaha, S. S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S224 - S224
  • [35] Continuous Flow Rotary Left Ventricular Assist Device Mechanical Circulatory Support 2.0
    Eisen, Howard J.
    Hankins, Shelley R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (04) : 322 - 324
  • [36] Post Transplant Survival Following Support with a Continuous Flow Left Ventricular Assist Device
    John, R.
    Pagant, F. D.
    Naka, Y.
    Russell, S. D.
    Boule, A. J.
    Klodell, C. T.
    Rogers, J. G.
    Farrar, D. J.
    Frazier, O. H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S165 - S165
  • [37] Effects of Continuous Flow Left Ventricular Assist Device Support on Microvascular Endothelial Function
    Xiaoying Lou
    Danielle L. Templeton
    Ranjit John
    Donald R. Dengel
    Journal of Cardiovascular Translational Research, 2012, 5 : 345 - 350
  • [38] Transvenous lead extractions in patients on continuous flow left ventricular assist device support
    Starck, C. T.
    Eulert-Grehn, J. J.
    Lanmueller, P.
    Potapov, E.
    Falk, V.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1911 - 1911
  • [39] Effects of Continuous Flow Left Ventricular Assist Device Support on Microvascular Endothelial Function
    Lou, Xiaoying
    Templeton, Danielle L.
    John, Ranjit
    Dengel, Donald R.
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2012, 5 (03) : 345 - 350
  • [40] Defining pulsatility during continuous-flow ventricular assist device support
    Soucy, Kevin G.
    Koenig, Steven C.
    Giridharan, Guruprasad A.
    Sobieski, Michael. A.
    Slaughter, Mark S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (06): : 581 - 587