Phasic coronary blood flow pattern during a continuous flow left ventricular assist support

被引:34
|
作者
Ootaki, Y [1 ]
Kamohara, K [1 ]
Akiyama, M [1 ]
Zahr, F [1 ]
Kopcak, MW [1 ]
Dessoffy, R [1 ]
Fukamachi, K [1 ]
机构
[1] Cleveland Clin Fdn, Lerner Res Int, Dept Biomed Engn, Cleveland, OH 44195 USA
关键词
circulatory assistance; left ventricular assist device; perfusion;
D O I
10.1016/j.ejcts.2005.08.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Continuous flow left ventricular assist devices (LVADs) have been introduced and tested as a bridge to heart transplantation, bridge to recovery, and destination therapy, and several studies have been conducted to assess the physiologic effects of continuous flow LVADs. However, the effect of reduced pulsatility on the phasic coronary blood flow pattern is unknown. The aim of this study was to investigate the phasic coronary blood flow patterns during continuous flow LVAD support. Methods: Phasic coronary blood flow patterns and hemodynamic data were analyzed using three flow probes placed around the left anterior descending coronary artery (LAD), Left circumflex coronary artery (LCX), and the right coronary artery (RCA) in 16 pigs before and after initiating the LVAD support with or without creating LAD stenosis. Results: The total coronary blood flow (TCBF, 112.8 +/- 31.4 mL/min) gradually decreased when the continuous flow LVAD support increased to 2.0 L/min (110.7 +/- 29.0 mL/min, P = 0.571), 2.5 L/min (103.7 +/- 26.1 mL/min, P = 0.079), and 3.0 L/min (101.5 +/- 27.2 mL/min, P = 0.027) because of decreases in LAD flow and LCX flow. LVAD support caused decrease in systolic and peak systolic LAD flow, LCX flow, and RCA flow, whereas diastolic RCA flow increased. In the presence of LAD stenosis, the TCBF (97.7 +/- 36.1 mL/min) decreased when the continuous flow LVAD support increased to 2.0 L/min (83.9 +/- 22.1 mL/min, P = 0.029), 2.5 L/min (83.2 +/- 25.2 mL/min, P = 0.012), and 3.0 L/min (87.6 +/- 23.4 mL/min, P = 0.005) because of decreases in LCX flow. Conclusion: Use of a continuous flow LVAD decreased TCBF, LAD flow, and LCX flow secondary to reduced systotic LAD flow and LCX flow, and decreased TCBF and LCX flow in the presence of LAD stenosis. These findings are potentially relevant to understanding the physiology of myocardial blood perfusion during continuous flow LVAD support especially in patients with coronary artery disease. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:711 / 716
页数:6
相关论文
共 50 条
  • [21] Hemolysis and Von Willebrand Factor Levels During Continuous Flow Left Ventricular Assist Device Support
    Saeed, O.
    Rangasamy, S.
    Luke, A.
    Patel, S. R.
    Shin, J.
    Sims, D. B.
    Gil, M. Reyes
    Goldstein, D. J.
    Slepian, M. J.
    Billett, H. H.
    Jorde, U.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S247 - S247
  • [22] Fusion of the aortic valve commissures during continuous axial flow left ventricular assist device support
    Mudd, James
    Cuda, Johnathan D.
    Conte, John V.
    Halushka, Marc K.
    Russell, Stuart D.
    CIRCULATION, 2007, 116 (16) : 373 - 373
  • [23] Gender differences in the risk of stroke during support with continuous-flow left ventricular assist device
    Morris, Alanna A.
    Pekarek, Ann
    Wittersheim, Kris
    Cole, Robert T.
    Gupta, Divya
    Duc Nguyen
    Laskar, S. Raja
    Butler, Javed
    Smith, Andrew
    Vega, J. David
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (12): : 1570 - 1577
  • [24] Gastrointestinal Bleeding During Continuous-Flow Left Ventricular Assist Device Support State of the Field
    Kataria, Rachna
    Jorde, Ulrich P.
    CARDIOLOGY IN REVIEW, 2019, 27 (01) : 8 - 13
  • [25] SYNCHRONIZED PULSATILE FLOW WITH A CONTINUOUS FLOW LEFT VENTRICULAR ASSIST DEVICE
    Rutten, M. C. M.
    Tuzun, E.
    de Vosse, F. N. van
    de Mol, B. A.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2010, 33 (07): : 449 - 449
  • [26] Evaluation of Platelet Activation by Flow Cytometry in Contemporary Continuous Flow Left Ventricular Assist Device Support
    Muthiah, K.
    Connor, D.
    Eckford, H.
    Robson, D.
    Joseph, J.
    Hayward, C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (04): : S390 - S390
  • [27] Impact of continuous-flow left ventricular assist device support on right ventricular function
    Morgan, Jeffrey A.
    Paone, Gaetano
    Nemeh, Hassan W.
    Murthy, Raghav
    Williams, Celeste T.
    Lanfear, David E.
    Tita, Cristina
    Brewer, Robert J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : 398 - 403
  • [28] Pressure, Flow Rate and Operating Speed Characteristics of a Continuous Flow Left Ventricular Assist Device During Varying Speed Support
    Bozkurt, Selim
    IEEE ACCESS, 2020, 8 : 129830 - 129841
  • [29] Phasic coronary blood flow velocity pattern and flow reserve in the atrium: Regulation of left atrial myocardial perfusion
    Skalidis, EI
    Kochladakis, GE
    Igoumenidis, NE
    Vardakis, KE
    Vardas, PE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (04) : 674 - 680
  • [30] Derivation of Indices of Left Ventricular Contractility in the Setting of Continuous-Flow Left Ventricular Assist Device Support
    Gupta, Sunil
    Muthiah, Kavitha
    Woldendorp, Kei
    Robson, Desiree
    Jansz, Paul
    Hayward, Christopher S.
    ARTIFICIAL ORGANS, 2014, 38 (12) : 1029 - 1034