Impact of turbulent blood flow in the aortic root on de novo aortic insufficiency during continuous-flow left ventricular-assist device support

被引:15
|
作者
Yoshida, Shohei [1 ]
Toda, Koichi [1 ]
Miyagawa, Shigeru [1 ]
Yoshikawa, Yasushi [1 ]
Hata, Hiroki [1 ]
Yoshioka, Daisuke [1 ]
Kainuma, Satoshi [1 ]
Kawamura, Takuji [1 ]
Kawamura, Ai [1 ]
Nakatani, Satoshi [2 ]
Sawa, Yoshiki [1 ]
机构
[1] Osaka Univ, Cardiovasc Surg, 2-2 Yamadaoka Suita, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Cardiovasc Med, Suita, Osaka, Japan
关键词
blood flow analysis; computational fluid dynamics; de novo aortic insufficiency; left ventricular assist device; COMPUTATIONAL FLUID-DYNAMICS; CIRCULATORY SUPPORT; IMPLANTATION; VALVE; REGURGITATION; LOCATION; WALL;
D O I
10.1111/aor.13671
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Severe aortic insufficiency (AI) after implantation of continuous-flow left ventricular-assist device (LVAD) affects device performance and outcomes. However, the mechanism for the occurrence and progression of AI has not been elucidated. We investigated the impact of nonphysiological retrograde blood flow in the aortic root on AI after LVAD implantation. Blood flow pattern was analyzed in patients with and without AI (n = 3 each) who underwent LVAD implantation, by computational fluid dynamics with patient-specific geometries, which were reproduced using electrocardiogram-gated 320-slice computed tomographic images. The total volume of retrograde blood flow during one cardiac cycle (716 +/- 88 mL) was higher and the volume of slow blood flow (<0.1 cm/s) (0.16 +/- 0.04 cm(3)) was lower in patients with AI than in those without AI (360 +/- 111 mL, P = .0495, and 0.49 +/- 0.08 cm(3), P = .0495, respectively). No significant difference in wall shear stress on the aortic valve was observed between the groups. Patients with AI had a perpendicular anastomosis at the distal ascending aorta and the simulation in the modified anastomosis model of patients with AI showed that the retrograde blood flow pattern depended on the angle and position of anastomosis. Computational fluid dynamics revealed strong retrograde blood flow in the ascending aorta and aortic root in patients with AI after LVAD implantation. The angle and position of LVAD outflow anastomosis might impact retrograde blood flow and de novo AI after LVAD implantation.
引用
收藏
页码:883 / 891
页数:9
相关论文
共 50 条
  • [1] De Novo Aortic Regurgitation After Continuous-Flow Left Ventricular Assist Device Implantation
    Patil, Nikhil Prakash
    Sabashnikov, Anton
    Mohite, Prashant N.
    Garcia, Diana
    Weymann, Alexander
    Zych, Bartlomiej
    Bowles, Christopher T.
    Hards, Rachel
    Hedger, Michael
    Popov, Aron F.
    De Robertis, Fabio
    Moza, Ajay
    Bahrami, Toufan
    Amrani, Mohamed
    Rahman-Haley, Shelley
    Banner, Nicholas R.
    Simon, Andre Ruediger
    ANNALS OF THORACIC SURGERY, 2014, 98 (03): : 850 - 857
  • [2] De Novo Aortic Regurgitation After Continuous-Flow Left Ventricular Assist Device Implantation
    Gasparovic, Hrvoje
    Kopjar, Tomislav
    Saeed, Diyar
    Cikes, Maja
    Svetina, Lucija
    Petricevic, Mate
    Lovric, Daniel
    Milicic, Davor
    Biocina, Bojan
    ANNALS OF THORACIC SURGERY, 2017, 104 (02): : 704 - 711
  • [3] Computational fluid dynamics visualizes turbulent flow in the aortic root of a patient under continuous-flow left ventricular assist device support
    Yoshida, Shohei
    Toda, Koichi
    Miyagawa, Shigeru
    Sawa, Yoshiki
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 159 (03): : E205 - E207
  • [4] Consequences of aortic insufficiency during long-term axial continuous-flow left ventricular assist device support
    Cowger, Jennifer A.
    Aaronson, Keith D.
    Romano, Matthew A.
    Haft, Jonathan
    Pagani, Francis D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (12): : 1233 - 1240
  • [5] Spontaneous microbubbles in the aortic root and thrombosis of a continuous-flow left ventricular assist device
    Raina, Amresh
    Agarwal, Richa
    Benza, Raymond L.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (05): : 550 - 551
  • [6] Impact of Aortic Insufficiency on Unloading Properties of Continuous-Flow Left Ventricular Assist Devices
    Sayer, G.
    Kruse, E.
    Addetia, K.
    Grinstein, J.
    Adatya, S.
    Sarswat, N.
    Kim, G. H.
    Ota, T.
    Jeevanandam, V.
    Lang, R.
    Uriel, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S385 - S385
  • [7] The Development of Aortic Insufficiency in Continuous-Flow Left Ventricular Assist Device-Supported Patients
    Aggarwal, Ashim
    Raghuvir, Rashmi
    Eryazici, Paula
    Macaluso, Gregory
    Sharma, Priya
    Blair, Christopher
    Tatooles, Antone J.
    Pappas, Pat S.
    Bhat, Geetha
    ANNALS OF THORACIC SURGERY, 2013, 95 (02): : 493 - 499
  • [8] Monitoring of Aortic Valve Opening and Systolic Aortic Insufficiency in Optimization of Continuous-Flow Left Ventricular Assist Device Settings
    Gologorsky, Edward
    Gologorsky, Angela
    Pham, Si M.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2012, 26 (06) : 1063 - 1066
  • [9] Aortic insufficiency in continuous-flow left ventricular assist device support patients is common but does not impact long-term mortality
    Holley, Christopher T.
    Fitzpatrick, Megan
    Roy, Samit S.
    Alraies, M. Chadi
    Cogswell, Rebecca
    Souslian, Laura
    Eckman, Peter
    John, Ranjit
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (01): : 91 - 96
  • [10] Management of aortic insufficiency in the continuous flow left ventricular assist device population
    Holtz J.
    Teuteberg J.
    Current Heart Failure Reports, 2014, 11 (1) : 103 - 110