Optimisation of antenna array allocation for partial discharge localisation in air-insulated substation

被引:4
|
作者
Zhu, Ming-Xiao [1 ]
Liu, Qing [1 ]
Wang, Yan-Bo [1 ]
Li, Yuan [1 ]
Deng, Jun-Bo [1 ]
Mu, Hai-Bao [1 ]
Zhang, Guan-Jun [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, State Key Lab Elect Insulat & Power Equipment, 28 Xianning West Rd, Xian, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
antenna arrays; power grids; numerical analysis; partial discharges; power transformer insulation; antenna array allocation optimisation; partial discharge localisation; air-insulated substation; insulation breakdown; power equipment; Cramer-Rao lower bound; numerical simulation; optimum antenna configurations; coordinate estimation; PD DIAGNOSTICS; LOCATION; ALGORITHM; SYSTEM;
D O I
10.1049/iet-smt.2017.0064
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharge (PD) is the symptom of insulation breakdown in power equipment. The high rising steepness of PD current radiates electromagnetic waves which can be coupled with antenna. In this study, an antenna array is applied to PD detection and localisation in air-insulated substations, in which the locations of PD sources are found with time difference of arrival localisation algorithm. The influences of antenna deployment including the size, aspect ratio and shape of antenna array on localisation accuracy are systematically investigated. Three approaches including Cramer-Rao lower bound, numerical simulation of root of mean square error and experiments are adopted to evaluate the localisation accuracy. Three kinds of antenna arrays with diamond, rectangle and Y shapes are designed for locating the coordinates of PD sources. Their localisation performances are compared by these evaluation approaches, and the optimum antenna configurations for coordinate estimation are derived. The results indicate that the optimum array is dependent on aspect ratio of array size. If the aspect ratio is higher than 0.5, the rectangle array gives minimum localisation error and wide bearing ranges with low error. For array with aspect ratio smaller than 0.25, the diamond array is optimum among the three shapes.
引用
收藏
页码:967 / 975
页数:9
相关论文
共 50 条
  • [1] Radiometric localisation of partial discharge sources inside Air-insulated electrical substation
    Mishra, Dipak Kumar
    Bhukya, Anitha
    Koley, Chiranjib
    Roy, Nirmal Kumar
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (08) : 1122 - 1130
  • [2] Localization of Multiple Partial Discharge Sources in Air-Insulated Substation Space by RF Antenna Sensors Array
    Zhou, Shengqi
    Wu, Shiyou
    Xiong, Haiqiang
    Qiu, Riqiang
    Sun, Yule
    Zheng, Shusheng
    Yang, Zehong
    [J]. IEEE SENSORS JOURNAL, 2022, 22 (14) : 14481 - 14490
  • [3] Method for partial discharge localisation in air-insulated substations
    Li, Pengfei
    Zhou, Wenjun
    Yang, Shuai
    Liu, Yushun
    Tian, Yan
    Wang, Yong
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2017, 11 (03) : 331 - 338
  • [4] UHF Antenna Configuration Optimization for Partial Discharge Source Localization in Air-Insulated Substation
    Zhu, Ming-Xiao
    Zhang, Jia-Ning
    Liu, Qing
    Wang, Yan-Bo
    Deng, Jun-Bo
    Zhang, Guan-Jun
    Guo, An-Xiang
    Liu, Xiao-Wei
    [J]. 2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 873 - 876
  • [5] Location Determination of Partial Discharge Sources in Air-Insulated Substation
    Yue, Ziqi
    Liu, Zeqiu
    [J]. IWCMC 2021: 2021 17TH INTERNATIONAL WIRELESS COMMUNICATIONS & MOBILE COMPUTING CONFERENCE (IWCMC), 2021, : 1852 - 1855
  • [6] Intelligent learning approach for UHF partial discharge localisation in air-insulated substations
    Zheng, Quanfu
    Luo, Lingen
    Song, Hui
    Sheng, Gehao
    Jiang, Xiuchen
    [J]. HIGH VOLTAGE, 2020, 5 (05): : 583 - 590
  • [7] CAIS Compact Air-Insulated SubstationCAIS compact air-insulated substation
    F. Rentz
    [J]. e&i Elektrotechnik und Informationstechnik, 2000, 117 (10) : 629 - 634
  • [8] Partial discharge direction-of-arrival estimation in air-insulated substation by UHF wireless array and RSSI maximum likelihood estimator
    Han, Bei
    Luo, Lingen
    Sheng, Gehao
    Jiang, Xiuchen
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (23) : 5491 - 5497
  • [9] Partial Discharge Positioning Method in Air-Insulated Substation With Vehicle-Mounted UHF Sensor Array Based on RSSI and Regularization
    Wang, Ruoyu
    Yin, Baiqiang
    Yuan, Lifen
    Wang, Shudong
    Ding, Chengwei
    Lv, Xiaodong
    [J]. IEEE SENSORS JOURNAL, 2024, 24 (11) : 18267 - 18278
  • [10] Localization of Multiple Partial Discharge Sources in Air-Insulated Substation Using Probability-Based Algorithm
    Zhu, Ming-Xiao
    Wang, Yan-Bo
    Liu, Qing
    Zhang, Jia-Ning
    Deng, Jun-Bo
    Zhang, Guan-Jun
    Shao, Xian-Jun
    He, Wen-Lin
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (01) : 157 - 166