Localization of Multiple Partial Discharge Sources in Air-Insulated Substation Space by RF Antenna Sensors Array

被引:5
|
作者
Zhou, Shengqi [1 ]
Wu, Shiyou [2 ]
Xiong, Haiqiang [2 ]
Qiu, Riqiang [2 ]
Sun, Yule [3 ]
Zheng, Shusheng [4 ]
Yang, Zehong [5 ]
机构
[1] Univ Saskatchewan, Coll Engn, Saskatoon, SK S7N 5B5, Canada
[2] Jiangxi Elect Power Co State Grid, Nanchang Power Supply Branch, Nanchang 330069, Jiangxi, Peoples R China
[3] Fuzhou Univ, Coll Elect Engn & Automat, Fuzhou 350108, Peoples R China
[4] North China Elect Power Univ, Sch Elect & Elect Engn, Beijing 102206, Peoples R China
[5] Wuhan Univ, Sch Elect & Automat, Wuhan 430072, Peoples R China
基金
北京市自然科学基金;
关键词
Localize; partial discharge (PD); radio frequency (RF) antenna sensor; air-insulated substation (AIS); time difference of arrival (TDOA); PD SOURCE; LOCATION;
D O I
10.1109/JSEN.2022.3181012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a method to localize multiple partial discharge (PD) sources in air-insulated substation by using radio frequency (RF) antenna sensors combining with clustering algorithm, which solves the problem that multiple PD or interference sources are difficult to localize in air-insulated substation (AIS). Our research group made four omnidirectional RF antenna sensors, the detection frequency band was 250 MHz-3 GHz, the voltage standing wave ratio (VSWR) of the RF antenna in the detection frequency band was less than 2, which meets the detection requirements. The scenes of multiple PD sources in AIS were simulated in the laboratory, the time difference of arrival (TDOA) was collected through four RF antennas, and the clustering effects of K-means and Two Step algorithms were compared. Based on the normal distribution characteristics of TDOAs and the better Two Step algorithm, a 3 sigma -Two Step algorithm was proposed to process TDOAs and output the centers of TDOAs. Newton iterative algorithm was used to solve the localization equations. The results show that the average localization error of two PD sources was 0.21 m and that of three PD sources was 0.45 m. The PD localization tests were carried out in an actual AIS in China, the proposed method localized a corona discharge on a post insulator and a corona discharge on a disconnector. Through the verifications with an ultraviolet camera, it was obtained that the localization errors at each position were within the range of 0.6-2 m.
引用
收藏
页码:14481 / 14490
页数:10
相关论文
共 50 条
  • [1] Optimisation of antenna array allocation for partial discharge localisation in air-insulated substation
    Zhu, Ming-Xiao
    Liu, Qing
    Wang, Yan-Bo
    Li, Yuan
    Deng, Jun-Bo
    Mu, Hai-Bao
    Zhang, Guan-Jun
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2017, 11 (08) : 967 - 975
  • [2] Location Determination of Partial Discharge Sources in Air-Insulated Substation
    Yue, Ziqi
    Liu, Zeqiu
    [J]. IWCMC 2021: 2021 17TH INTERNATIONAL WIRELESS COMMUNICATIONS & MOBILE COMPUTING CONFERENCE (IWCMC), 2021, : 1852 - 1855
  • [3] Localization of Multiple Partial Discharge Sources in Air-Insulated Substation Using Probability-Based Algorithm
    Zhu, Ming-Xiao
    Wang, Yan-Bo
    Liu, Qing
    Zhang, Jia-Ning
    Deng, Jun-Bo
    Zhang, Guan-Jun
    Shao, Xian-Jun
    He, Wen-Lin
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (01) : 157 - 166
  • [4] UHF Antenna Configuration Optimization for Partial Discharge Source Localization in Air-Insulated Substation
    Zhu, Ming-Xiao
    Zhang, Jia-Ning
    Liu, Qing
    Wang, Yan-Bo
    Deng, Jun-Bo
    Zhang, Guan-Jun
    Guo, An-Xiang
    Liu, Xiao-Wei
    [J]. 2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 873 - 876
  • [5] UHF Sensors Based Localization of Partial Discharge Sources in Air-Insulated Electrical Substation Using TDOA and Relative RSS Information
    Dhara, Sourav
    Koley, Chiranjib
    Chakravorti, Sivaji
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [6] Radiometric localisation of partial discharge sources inside Air-insulated electrical substation
    Mishra, Dipak Kumar
    Bhukya, Anitha
    Koley, Chiranjib
    Roy, Nirmal Kumar
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (08) : 1122 - 1130
  • [7] Methods for Localization of Partial Discharge Sources within Air Insulated Electrical Substation
    Dhara, Sourav
    Koley, Chiranjib
    Chakravorti, Sivaji
    [J]. 2018 20TH NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2018,
  • [8] Detection and Localization of Partial Dsicharge in Air-Insulated Substations Using UHF Antenna Array
    Zhu, Ming-Xiao
    Wang, Yan-Bo
    Li, Yuan
    Mu, Hai-Bao
    Deng, Jun-Bo
    Shao, Xian-Jun
    Zhang, Guan-Jun
    [J]. 2016 3RD CONFERENCE ON POWER ENGINEERING AND RENEWABLE ENERGY (ICPERE), 2016, : 221 - 224
  • [9] Improved Methods for UHF Localization of Partial Discharge in Air-Insulated Substations
    Rashwan, Ahmed
    Reid, Alistair
    [J]. ENERGIES, 2023, 16 (10)
  • [10] Localization of E-M Interference Sources in Air-Insulated Substation using VHF/UHF Antenna Arrays
    Roehrich, Jozef
    Zydron, Pawel
    Szafraniak, Bartlomiej
    [J]. PROCEEDINGS OF THE 9TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2017), 2017, : 301 - 305