Optimisation of antenna array allocation for partial discharge localisation in air-insulated substation

被引:4
|
作者
Zhu, Ming-Xiao [1 ]
Liu, Qing [1 ]
Wang, Yan-Bo [1 ]
Li, Yuan [1 ]
Deng, Jun-Bo [1 ]
Mu, Hai-Bao [1 ]
Zhang, Guan-Jun [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, State Key Lab Elect Insulat & Power Equipment, 28 Xianning West Rd, Xian, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
antenna arrays; power grids; numerical analysis; partial discharges; power transformer insulation; antenna array allocation optimisation; partial discharge localisation; air-insulated substation; insulation breakdown; power equipment; Cramer-Rao lower bound; numerical simulation; optimum antenna configurations; coordinate estimation; PD DIAGNOSTICS; LOCATION; ALGORITHM; SYSTEM;
D O I
10.1049/iet-smt.2017.0064
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharge (PD) is the symptom of insulation breakdown in power equipment. The high rising steepness of PD current radiates electromagnetic waves which can be coupled with antenna. In this study, an antenna array is applied to PD detection and localisation in air-insulated substations, in which the locations of PD sources are found with time difference of arrival localisation algorithm. The influences of antenna deployment including the size, aspect ratio and shape of antenna array on localisation accuracy are systematically investigated. Three approaches including Cramer-Rao lower bound, numerical simulation of root of mean square error and experiments are adopted to evaluate the localisation accuracy. Three kinds of antenna arrays with diamond, rectangle and Y shapes are designed for locating the coordinates of PD sources. Their localisation performances are compared by these evaluation approaches, and the optimum antenna configurations for coordinate estimation are derived. The results indicate that the optimum array is dependent on aspect ratio of array size. If the aspect ratio is higher than 0.5, the rectangle array gives minimum localisation error and wide bearing ranges with low error. For array with aspect ratio smaller than 0.25, the diamond array is optimum among the three shapes.
引用
收藏
页码:967 / 975
页数:9
相关论文
共 50 条
  • [31] Measurement and simulation of magnetic field of a 132kV air-insulated substation in Malaysia
    Said, I
    Farag, AS
    Hussain, H
    Rahman, NA
    [J]. UPEC 2004: 39TH INTERNATIONAL UNIVERSITITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2005, : 219 - 222
  • [32] UHF Antenna Array Arrangement Optimization for Partial Discharge Direction Finding in Air-insulted Substation Based on Phased Array Theory
    Liu, Qing
    Zhu, Ming-Xiao
    Wang, Yan-Bo
    Deng, Jun-Bo
    Li, Yuan
    Zhang, Guan-Jun
    Shao, Xian-Jun
    Zhao, Xue-Feng
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (06) : 3657 - 3668
  • [33] Novel Method for Partial Discharge Detection in Gas Insulated Substation
    Wang, Chuanning
    Liu, Baowen
    Xu, Honghua
    Jin, Jiping
    Ma, Hongzhong
    [J]. 2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [34] Analysis of transient EMI of air-insulated substation disconnect operation based on Wigner-Ville Distribution
    Tao, JS
    Chen, SX
    Zhang, XX
    [J]. EMC 2005: IEEE International Symposium on Electromagnetic Compatibility, Vols 1-3, Proceedings, 2005, : 851 - 855
  • [35] Analysis of electromagnetic transients in secondary circuits due to disconnector switching in 400 kV air-insulated substation
    Filipovic-Grcic, B.
    Uglesic, I.
    Milardic, V.
    Filipovic-Grcic, D.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2014, 115 : 11 - 17
  • [36] Switching Surge Analysis of an EHV Air-Insulated Substation Using the 3-D FDTD Method
    Tatematsu, Akiyoshi
    Moriguchi, Soichi
    Ueda, Toshiaki
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (05) : 2324 - 2334
  • [37] Analysis of Partial Discharge Signals in 420 kV Gas Insulated Substation
    Prabakaran, T.
    Usa, S.
    Kumar, Santosh A.
    [J]. 2013 IEEE 1ST INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON), 2013, : 249 - 254
  • [38] DIAGNOSTIC-TECHNIQUE OF GAS INSULATED SUBSTATION BY PARTIAL DISCHARGE DETECTION
    KUSUMOTO, S
    ITOH, S
    TSUCHIYA, Y
    MUKAE, H
    MATSUDA, S
    TAKAHASHI, K
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (04): : 1456 - 1465
  • [39] Study of propagation phenomena of partial discharge pulses in gas insulated substation
    Sakakibara, T
    Murase, H
    Haginomori, E
    Wakabayashi, S
    Emoto, K
    Ogawa, A
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (03) : 768 - 776
  • [40] FDTD-Based Lightning Surge Simulation of an HV Air-Insulated Substation With Back-Flashover
    Tatematsu, Akiyoshi
    Ueda, Toshiaki
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2016, 58 (05) : 1549 - 1560