Optimisation of antenna array allocation for partial discharge localisation in air-insulated substation

被引:4
|
作者
Zhu, Ming-Xiao [1 ]
Liu, Qing [1 ]
Wang, Yan-Bo [1 ]
Li, Yuan [1 ]
Deng, Jun-Bo [1 ]
Mu, Hai-Bao [1 ]
Zhang, Guan-Jun [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, State Key Lab Elect Insulat & Power Equipment, 28 Xianning West Rd, Xian, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
antenna arrays; power grids; numerical analysis; partial discharges; power transformer insulation; antenna array allocation optimisation; partial discharge localisation; air-insulated substation; insulation breakdown; power equipment; Cramer-Rao lower bound; numerical simulation; optimum antenna configurations; coordinate estimation; PD DIAGNOSTICS; LOCATION; ALGORITHM; SYSTEM;
D O I
10.1049/iet-smt.2017.0064
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharge (PD) is the symptom of insulation breakdown in power equipment. The high rising steepness of PD current radiates electromagnetic waves which can be coupled with antenna. In this study, an antenna array is applied to PD detection and localisation in air-insulated substations, in which the locations of PD sources are found with time difference of arrival localisation algorithm. The influences of antenna deployment including the size, aspect ratio and shape of antenna array on localisation accuracy are systematically investigated. Three approaches including Cramer-Rao lower bound, numerical simulation of root of mean square error and experiments are adopted to evaluate the localisation accuracy. Three kinds of antenna arrays with diamond, rectangle and Y shapes are designed for locating the coordinates of PD sources. Their localisation performances are compared by these evaluation approaches, and the optimum antenna configurations for coordinate estimation are derived. The results indicate that the optimum array is dependent on aspect ratio of array size. If the aspect ratio is higher than 0.5, the rectangle array gives minimum localisation error and wide bearing ranges with low error. For array with aspect ratio smaller than 0.25, the diamond array is optimum among the three shapes.
引用
收藏
页码:967 / 975
页数:9
相关论文
共 50 条
  • [21] RF-Based Partial Discharge Early Warning System for Air-Insulated Substations
    Portugues, Iliana E.
    Moore, Philip J.
    Glover, Ian A.
    Johnstone, Carl
    McKosky, Ralph H.
    Goff, Mark B.
    van der Zel, Luke
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (01) : 20 - 29
  • [22] Enhanced Bowtie UHF Antenna for Detecting Partial Discharge in Gas Insulated Substation
    Muslim, Joko
    Susilo, Achmad
    Nishigouchi, Kiichi
    Kozako, M.
    Hikita, Masayuki
    Arief, Yanuar Z.
    Khayam, Umar
    Suwarno
    [J]. 2013 48TH INTERNATIONAL UNIVERSITIES' POWER ENGINEERING CONFERENCE (UPEC), 2013,
  • [23] Long Bowtie Antenna for Partial Discharge Sensor in Gas-Insulated Substation
    Andre, Hanalde
    Emeraldi, Primas
    Hazmi, Ariadi
    Waldi, Eka Putra
    Khayam, Umar
    [J]. 2017 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND POWER SYSTEMS (ICHVEPS), 2017, : 175 - 178
  • [24] Electromagnetic radiation spectrum from partial discharge in air-insulated medium voltage switchgear
    Zheng, Bo
    Bojovschi, Alexe
    Chen, Xinpeng
    [J]. 2012 POWER ENGINEERING AND AUTOMATION CONFERENCE (PEAM), 2012, : 219 - 222
  • [25] Methods for Localization of Partial Discharge Sources within Air Insulated Electrical Substation
    Dhara, Sourav
    Koley, Chiranjib
    Chakravorti, Sivaji
    [J]. 2018 20TH NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2018,
  • [26] Miniature Gas-Sensing Array Employed for the Discharge Fault Diagnosis of Air-Insulated Equipment
    Wang, Qiongyuan
    Chu, Jifeng
    Li, Qiulin
    Yang, Aijun
    Yuan, Huan
    Rong, Mingzhe
    Wang, Xiaohua
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (23): : 6494 - 6502
  • [27] Localization of E-M Interference Sources in Air-Insulated Substation using VHF/UHF Antenna Arrays
    Roehrich, Jozef
    Zydron, Pawel
    Szafraniak, Bartlomiej
    [J]. PROCEEDINGS OF THE 9TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2017), 2017, : 301 - 305
  • [28] Study on characteristics gases of metal protrusions partial discharge in 10-kV air-insulated switchgear
    Tan, Qipeng
    Song, Bin
    Wang, Linong
    Wu, Shaocheng
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2023, 17 (06) : 221 - 229
  • [29] Application of magneto-optical sensors for fault location in an air-insulated substation bus
    Mizuno, K
    Katsukawa, H
    Sakurai, Y
    Tanaka, N
    [J]. ELECTRICAL ENGINEERING IN JAPAN, 1997, 119 (02) : 10 - 17
  • [30] Statistical analysis on measured lightning overvoltage surges in a 110 kV air-insulated substation
    Sima, Wenxia
    Lan, Xing
    Yang, Qing
    Yuan, Tao
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2015, 9 (01) : 28 - 36