The Effect of Positional Movement of a Semiflexible Applicator on Dose Distrubutions in Low Dose Rate Brachytherapy for Cervical Carcinoma

被引:0
|
作者
Kucucuk, Seden [1 ]
Kemikler, Gonul [2 ]
Okutan, Murat [2 ]
Aslay, Isik [1 ]
Disci, Rian [3 ]
Alas, Rusen Cosar [4 ]
Tore, Gokhan [1 ]
机构
[1] Istanbul Univ, Inst Oncol, Dept Radiat Oncol, Istanbul, Turkey
[2] Istanbul Univ, Inst Oncol, Dept Med Phys, Istanbul, Turkey
[3] Istanbul Univ, Istanbul Fac Med, Dept Biostat, Istanbul, Turkey
[4] Trakya Univ, Fac Med, Dept Radiat Oncol, Edirne, Turkey
来源
关键词
Brachytherapy; uterine cervical neoplasms; MAJOR GEOMETRIC VARIATIONS; UTERINE CERVIX; INTRACAVITARY BRACHYTHERAPY; RADIATION-THERAPY; HDR BRACHYTHERAPY; CANCER; INSERTIONS; SYSTEM; TANDEM; PARAMETERS;
D O I
10.5336/medsci.2009-14229
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Current study aims to detect the movements of a semiflexible applicator (TORE's applicator) in the first 24 hours and to analyze its effect on the calculated point A, bladder and rectum doses in low dose rate brachytherapy (LDR-BT) applications. Material and Methods: Eighty films were evaluated on 18 cervical carcinoma patients (20 applications) who were treated with curative radiotherapy. The comparison of the reference points and doses at critical organs were performed by using a reference axis which was fixed to bony landmarks in the pelvis. To evaluate the movement of the applicator, distance of the upper point and lower point of the tandem to the reference axis were measured. Additionally, the angular deviation of the applicator was tested. Results: The movements of the upper point and lower point of the tandem in x, y, z axes were 5.30 +/- 6.33 mm, 2.80 +/- 2.24 mm, 6.65 +/- 8.33 mm and 3.45 +/- 4.32 mm, 3.75 +/- 3.59 mm, 3.05 +/- 3.08 mm, respectively. The mean differences were 3.30 +/- 2.99 degrees in alpha-angle and 5.65 +/- 4.76 degrees in beta-angle. The mean percent dose changes in point A, bladder and rectum were 1.5 +/- 1.2%, 3.7 +/- 3.1%, 4.4 +/- 4.0%, respectively. Conclusion: Our study demonstrates that there are some movements of the applicator during LDR-BT, however these movements do not result in significant dose changes in target volumes and critical organs. Therefore, positional correction is not required. In conclusion, CT-compatible TORE's applicator that allows an advantage for CT-based 3D planning is useful and safe for brachytherapy.
引用
收藏
页码:1858 / 1868
页数:11
相关论文
共 50 条
  • [41] Current controversies in high-dose-rate versus low-dose-rate brachytherapy for cervical cancer
    Stewart, Alexandra J.
    Viswanathan, Akila N.
    CANCER, 2006, 107 (05) : 908 - 915
  • [42] Development of a Machine Learning Model for Optimal Applicator Selection in High-Dose-Rate Cervical Brachytherapy
    Stenhouse, Kailyn
    Roumeliotis, Michael
    Banerjee, Robyn
    Yanushkevich, Svetlana
    McGeachy, Philip
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [43] Preliminary report of a single-channel applicator in high dose rate afterloading brachytherapy for cervical cancer
    Li, Dan
    Wen, En
    Zhang, Yingjie
    Wu, Zhouxue
    Pang, Haowen
    Ren, Peirong
    Shang, Changling
    He, Lijia
    Zhang, Jianwen
    Xiang, Li
    Yang, Hongru
    Liu, Qiaoli
    Wen, Qinglian
    Fan, Juan
    Lin, Sheng
    Wu, Jingbo
    CANCER SCIENCE, 2018, 109 (12): : 3953 - 3961
  • [44] Low dose rate prostate brachytherapy
    Stish, Bradley J.
    Davis, Brian J.
    Mynderse, Lance A.
    McLaren, Robert H.
    Deufel, Christopher L.
    Choo, Richard
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2018, 7 (03) : 341 - 356
  • [45] Pulsed-Dose-Rate Intracavitary Brachytherapy for Cervical Carcinoma The AIIMS Experience
    Rath, Goura K.
    Sharma, Daya N.
    Julka, Parmod K.
    Subramani, Vellaiyan
    Bahl, Amit
    Haresh, Kunhi P.
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2010, 33 (03): : 238 - 241
  • [46] High-dose-rate interstitial brachytherapy for previously untreated cervical carcinoma
    Isohashi, Fumiaki
    Yoshioka, Yasuo
    Koizumi, Masahiko
    Konishi, Koji
    Sumida, Iori
    Takahashi, Yutaka
    Ogata, Toshiyuki
    Morishige, Ken-ichirou
    Enomoto, Takayuki
    Kawaguchi, Yoshifumi
    Kotsuma, Tadayuki
    Adachi, Kana
    Fukuda, Shoichi
    Akino, Yuichi
    Inoue, Takehiro
    BRACHYTHERAPY, 2009, 8 (02) : 234 - 239
  • [47] A COMPARISON OF THE EFFICACY AND COMPLICATION RATES OF LOW DOSE-RATE VERSUS HIGH-DOSE-RATE BRACHYTHERAPY IN THE TREATMENT OF UTERINE CERVICAL-CARCINOMA
    SARKARIA, JN
    PETEREIT, DG
    STITT, JA
    HARTMAN, T
    CHAPPELL, R
    THOMADSEN, BR
    BUCHLER, DA
    FOWLER, JF
    KINSELLA, TJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (01): : 75 - 82
  • [48] Pulsed dose rate and fractionated high dose rate brachytherapy: Choice of brachytherapy schedules to replace low dose rate treatments
    Visser, AG
    vandenAardweg, GJMJ
    Levendag, PC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (02): : 497 - 505
  • [49] Results of cervical carcinoma treated with external Radiotherapy and high dose rate Brachytherapy
    Lemos, MJ
    Monterrey, MO
    Condon, O
    Grillo, IM
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S76 - S76
  • [50] Clinical Experience with Pulse Dose Rate Brachytherapy for Conservative Treatment of Penile Carcinoma and Comparison with Historical Data of Low Dose Rate Brachytherapy
    Kamsu-Kom, L.
    Bidault, F.
    Mazeron, R.
    Baratiny, C.
    Martin, V.
    Maroun, P.
    Dumas, I.
    Guemnie-Tafo, A.
    Martinetti, F.
    Gerbaulet, A.
    Chargari, C.
    Haie-Meder, C.
    CLINICAL ONCOLOGY, 2015, 27 (07) : 387 - 393