The Effect of Positional Movement of a Semiflexible Applicator on Dose Distrubutions in Low Dose Rate Brachytherapy for Cervical Carcinoma

被引:0
|
作者
Kucucuk, Seden [1 ]
Kemikler, Gonul [2 ]
Okutan, Murat [2 ]
Aslay, Isik [1 ]
Disci, Rian [3 ]
Alas, Rusen Cosar [4 ]
Tore, Gokhan [1 ]
机构
[1] Istanbul Univ, Inst Oncol, Dept Radiat Oncol, Istanbul, Turkey
[2] Istanbul Univ, Inst Oncol, Dept Med Phys, Istanbul, Turkey
[3] Istanbul Univ, Istanbul Fac Med, Dept Biostat, Istanbul, Turkey
[4] Trakya Univ, Fac Med, Dept Radiat Oncol, Edirne, Turkey
来源
关键词
Brachytherapy; uterine cervical neoplasms; MAJOR GEOMETRIC VARIATIONS; UTERINE CERVIX; INTRACAVITARY BRACHYTHERAPY; RADIATION-THERAPY; HDR BRACHYTHERAPY; CANCER; INSERTIONS; SYSTEM; TANDEM; PARAMETERS;
D O I
10.5336/medsci.2009-14229
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Current study aims to detect the movements of a semiflexible applicator (TORE's applicator) in the first 24 hours and to analyze its effect on the calculated point A, bladder and rectum doses in low dose rate brachytherapy (LDR-BT) applications. Material and Methods: Eighty films were evaluated on 18 cervical carcinoma patients (20 applications) who were treated with curative radiotherapy. The comparison of the reference points and doses at critical organs were performed by using a reference axis which was fixed to bony landmarks in the pelvis. To evaluate the movement of the applicator, distance of the upper point and lower point of the tandem to the reference axis were measured. Additionally, the angular deviation of the applicator was tested. Results: The movements of the upper point and lower point of the tandem in x, y, z axes were 5.30 +/- 6.33 mm, 2.80 +/- 2.24 mm, 6.65 +/- 8.33 mm and 3.45 +/- 4.32 mm, 3.75 +/- 3.59 mm, 3.05 +/- 3.08 mm, respectively. The mean differences were 3.30 +/- 2.99 degrees in alpha-angle and 5.65 +/- 4.76 degrees in beta-angle. The mean percent dose changes in point A, bladder and rectum were 1.5 +/- 1.2%, 3.7 +/- 3.1%, 4.4 +/- 4.0%, respectively. Conclusion: Our study demonstrates that there are some movements of the applicator during LDR-BT, however these movements do not result in significant dose changes in target volumes and critical organs. Therefore, positional correction is not required. In conclusion, CT-compatible TORE's applicator that allows an advantage for CT-based 3D planning is useful and safe for brachytherapy.
引用
收藏
页码:1858 / 1868
页数:11
相关论文
共 50 条
  • [21] Curative radiotherapy with high-dose-rate brachytherapy boost for localized esophageal carcinoma: dose-effect relationship of brachytherapy with the balloon type applicator system
    Yorozu, A
    Dokiya, T
    Oki, Y
    Suzuki, T
    RADIOTHERAPY AND ONCOLOGY, 1999, 51 (02) : 133 - 139
  • [22] Low-Dose-Rate Versus High-Dose-Rate Versus Pulsed-Dose-Rate Intracavitary Brachytherapy in Cervical Carcinoma: A Monoinstitutional Comparative Study
    Sharma, D. N.
    Rath, G. K.
    Gandhi, A. K.
    Kumar, P.
    Haresh, K.
    Gupta, S.
    Pandey, R.
    Giridhar, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E278 - E278
  • [23] Validation of a Machine Learning Algorithm for Applicator Selection in High-Dose-Rate Cervical Brachytherapy
    Stenhouse, K.
    Roumeliotis, M.
    McGeachy, P.
    Baker, Tom
    MEDICAL PHYSICS, 2020, 47 (06) : E370 - E371
  • [24] Dosimetric evaluation of a newly designed low dose rate brachytherapy applicator for treatment of cervical cancer with extension into the lower vagina
    Baker, Curtis
    Dini, Sharifeh A.
    Kudrimoti, Mahesh
    Awan, Shahid B.
    Meigooni, Ali S.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (02): : 37 - 46
  • [25] A novel applicator for delivery of low-dose-rate brachytherapy for patients with gynecologic cancers
    Wolfson, AH
    Wu, X
    Takita, C
    Shao, H
    Chen, ZP
    Diaz, D
    RADIOLOGY, 2001, 221 : 604 - 604
  • [26] EVALUATION OF RECTAL DOSE DURING HIGH-DOSE-RATE INTRACAVITARY BRACHYTHERAPY FOR CERVICAL CARCINOMA
    Sha, Rajib Lochan
    Reddy, Palreddy Yadagiri
    Rao, Ramakrishna
    Muralidhar, Kanaparthy R.
    Kudchadker, Rajat J.
    MEDICAL DOSIMETRY, 2011, 36 (04) : 377 - 382
  • [27] Megavoltage CT image-based intracavitary low dose rate brachytherapy for cervical carcinoma
    Wagner, TH
    Buchholz, D
    Forbes, A
    Willoughby, TR
    Meeks, SL
    Kupelian, PA
    Zeidan, OA
    Langen, KM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S338 - S339
  • [28] High dose rate (HDR) cervical ring applicator to control bleeding from cervical carcinoma
    Grigsby, PW
    Portelance, L
    Williamson, JF
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2002, 12 (01) : 18 - 21
  • [29] High dose rate (HDR) cervical ring applicator to control bleeding from cervical carcinoma
    Rath, GK
    Sharma, DN
    Parida, DK
    Gairola, M
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2003, 13 (03) : 389 - 390
  • [30] Commissioning of High Dose Rate Brachytherapy Surface Applicator System
    Wichman, B.
    Francom, D.
    Howard, T.
    Wilkinson, A.
    Posey, R.
    MEDICAL PHYSICS, 2021, 48 (06)