The Effect of Positional Movement of a Semiflexible Applicator on Dose Distrubutions in Low Dose Rate Brachytherapy for Cervical Carcinoma

被引:0
|
作者
Kucucuk, Seden [1 ]
Kemikler, Gonul [2 ]
Okutan, Murat [2 ]
Aslay, Isik [1 ]
Disci, Rian [3 ]
Alas, Rusen Cosar [4 ]
Tore, Gokhan [1 ]
机构
[1] Istanbul Univ, Inst Oncol, Dept Radiat Oncol, Istanbul, Turkey
[2] Istanbul Univ, Inst Oncol, Dept Med Phys, Istanbul, Turkey
[3] Istanbul Univ, Istanbul Fac Med, Dept Biostat, Istanbul, Turkey
[4] Trakya Univ, Fac Med, Dept Radiat Oncol, Edirne, Turkey
来源
关键词
Brachytherapy; uterine cervical neoplasms; MAJOR GEOMETRIC VARIATIONS; UTERINE CERVIX; INTRACAVITARY BRACHYTHERAPY; RADIATION-THERAPY; HDR BRACHYTHERAPY; CANCER; INSERTIONS; SYSTEM; TANDEM; PARAMETERS;
D O I
10.5336/medsci.2009-14229
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Current study aims to detect the movements of a semiflexible applicator (TORE's applicator) in the first 24 hours and to analyze its effect on the calculated point A, bladder and rectum doses in low dose rate brachytherapy (LDR-BT) applications. Material and Methods: Eighty films were evaluated on 18 cervical carcinoma patients (20 applications) who were treated with curative radiotherapy. The comparison of the reference points and doses at critical organs were performed by using a reference axis which was fixed to bony landmarks in the pelvis. To evaluate the movement of the applicator, distance of the upper point and lower point of the tandem to the reference axis were measured. Additionally, the angular deviation of the applicator was tested. Results: The movements of the upper point and lower point of the tandem in x, y, z axes were 5.30 +/- 6.33 mm, 2.80 +/- 2.24 mm, 6.65 +/- 8.33 mm and 3.45 +/- 4.32 mm, 3.75 +/- 3.59 mm, 3.05 +/- 3.08 mm, respectively. The mean differences were 3.30 +/- 2.99 degrees in alpha-angle and 5.65 +/- 4.76 degrees in beta-angle. The mean percent dose changes in point A, bladder and rectum were 1.5 +/- 1.2%, 3.7 +/- 3.1%, 4.4 +/- 4.0%, respectively. Conclusion: Our study demonstrates that there are some movements of the applicator during LDR-BT, however these movements do not result in significant dose changes in target volumes and critical organs. Therefore, positional correction is not required. In conclusion, CT-compatible TORE's applicator that allows an advantage for CT-based 3D planning is useful and safe for brachytherapy.
引用
收藏
页码:1858 / 1868
页数:11
相关论文
共 50 条
  • [31] High dose rate endobronchial brachytherapy using a new applicator
    Nomoto, Y
    Shouji, K
    Toyota, S
    Sasaoka, M
    Murashima, S
    Ooi, M
    Takeda, K
    Nakagawa, T
    RADIOTHERAPY AND ONCOLOGY, 1997, 45 (01) : 33 - 37
  • [32] Pulsed low dose rate brachytherapy for uterine cervix carcinoma
    Rogers, CL
    Freel, JH
    Speiser, BL
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (01): : 95 - 100
  • [33] The dose rate effect in brachytherapy
    Mazeron, J. J.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S229 - S230
  • [34] Dose rate correction in medium dose rate brachytherapy for carcinoma cervix
    Patel, FD
    Negi, PS
    Sharma, SC
    Kapoor, R
    Singh, DP
    Ghoshal, S
    RADIOTHERAPY AND ONCOLOGY, 1998, 49 (03) : 317 - 323
  • [35] AN ANALYSIS OF THE EFFICACY AND SAFETY OF HIGH-DOSE-RATE AS COMPARED TO LOW-DOSE RATE BRACHYTHERAPY IN THE TREATMENT OF UTERINE CERVICAL-CARCINOMA
    HARTMANN, TJ
    SARKARIA, JN
    PETEREIT, DG
    STITT, JA
    BUCHLER, DA
    CHAPPELL, R
    FOWLER, JF
    KINSELLA, TJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 : 130 - 130
  • [36] High versus low-dose rate brachytherapy for cervical cancer
    Patankar, Sonali S.
    Tergas, Ana I.
    Deutsch, Israel
    Burke, William M.
    Hou, June Y.
    Ananth, Cande V.
    Huang, Yongmei
    Neugut, Alfred I.
    Hershman, Dawn L.
    Wright, Jason D.
    GYNECOLOGIC ONCOLOGY, 2015, 136 (03) : 534 - 541
  • [37] Comparison of high-dose-rate and low-dose-rate brachytherapy in the treatment of endometrial carcinoma
    Fayed, Alaa
    Mutch, David G.
    Rader, Janet S.
    Gibb, Randall K.
    Powell, Matthew A.
    Wright, Jason D.
    ElNaqa, Issam
    Zoberi, Imran
    Grigsby, Perry W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (02): : 480 - 484
  • [38] High dose rate versus low dose rate brachytherapy in the treatment of tongue carcinoma - a radiobiological study
    Petera, J.
    Matula, P.
    Paluska, P.
    Sirak, I.
    Macingova, Z.
    Kasaova, L.
    Frgala, T.
    Hodek, M.
    Vosmik, M.
    NEOPLASMA, 2009, 56 (02) : 163 - 168
  • [39] Results and complications of high dose rate and low dose rate brachytherapy in carcinoma of the cervix:: Cerrahpasa experience
    Okkan, S
    Atkovar, G
    Sahinler, I
    Dinçbas, FÖ
    Koca, A
    Köksal, S
    Turkan, S
    Uzel, R
    RADIOTHERAPY AND ONCOLOGY, 2003, 67 (01) : 97 - 105
  • [40] HIGH-DOSE-RATE VERSUS LOW-DOSE-RATE INTRACAVITARY BRACHYTHERAPY FOR CARCINOMA OF THE CERVIX
    FU, KK
    PHILLIPS, TL
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (03): : 791 - 796