The influence of detector size relative to field size in small-field photon-beam dosimetry using synthetic diamond crystals as sensors

被引:6
|
作者
Ade, N.
Nam, T. L. [1 ]
机构
[1] Univ Witwatersrand, Sch Phys, Radiat & Hlth Phys Unit, ZA-2050 Johannesburg, South Africa
基金
新加坡国家研究基金会;
关键词
Synthetic diamonds; Small fields; Output factor; Detector size; Volume effect; HIGH-ENERGY ELECTRON; DOSE-RATE DEPENDENCE; MONTE-CARLO CALCULATIONS; CVD-DIAMOND; OUTPUT FACTORS; RADIATION-THERAPY; X-RAY; DEFECTS; PROBE;
D O I
10.1016/j.radphyschem.2015.04.005
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The choice of a detector for small-field dosimetry remains a challenge due to the size/volume effect of detectors in small fields. Aimed at selecting a suitable crystal type and detector size for small-field dosimetry, this study investigates the relationship between detector and field size by analysing output factors (0Fs) measured with a Diode E (reference detector), a Farmer chamber and synthetic diamond detectors of various types and sizes in the dosimetry of a 6 MV photon beam with small fields between 03 x 0.3 cm(2) and 10 x 10 cm(2). The examined diamond sensors included two HPHT samples (HP1 and HP2) and six polycrystalline CVD specimens of optical grade (OG) and detector grade (DG) qualities with sizes between 0.3 and 1.0 cm. Each diamond was encapsulated in a tissue-equivalent probe housing which can hold crystals of various dimensions up to 1.0 x 1.0 x 0.1 cm(3) and has different exposure geometries ('edge-on' and 'flat-on') for impinging radiation. The HPHT samples were found to show an overall better performance compared to the CVD crystals with the 'edge-on' orientation being a preferred geometry for OF measurement especially for very small fields. For instance, down to a 0.4 x 0.4 cm(2) field a maximum deviation of 1.9% was observed between the OFs measured with Diode E and HP2 in the 'edge-on' orientation compared to a 4.6% deviation in the 'flat-on' geometry. It was observed that for fields below 4 x 4 cm(2), the dose deviation between the OFs measured with the detectors and Diode E increase with increasing detector size. It was estimated from an established relationship between the dose deviation and the ratio of detector size to field size for the detectors that the dose deviation probably due to the volume averaging effect would be >3% when the detector size is >3/4 of the field size. A sensitivity value of 223 nC Gy(-1) mm(-3) was determined in a 0.5 x 0.5 cm(2) field with HP2 compared to a value of 159.2 nC Gy(-1) mm(-3) obtained with the diode. The results of this study indicate that with careful selection of a suitable crystal type of a given size and orientation the relative dose measured with the diamond probe in small fields would agree favourably within +/- 2% with that measured with a small-field detector but with a higher sensitivity value. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:6 / 13
页数:8
相关论文
共 50 条
  • [21] Multicenter evaluation of a synthetic single-crystal diamond detector for CyberKnife small field size output factors
    Russo, Serenella
    Masi, Laura
    Francescon, Paolo
    Frassanito, Maria Cristina
    Fumagalli, Maria Luisa
    Marinelli, Marco
    Falco, Maria Daniela
    Martinotti, Anna Stefania
    Pimpinella, Maria
    Reggiori, Giacomo
    Rinati, Gianluca Verona
    Vigorito, Sabrina
    Mancosu, Pietro
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (04): : 575 - 581
  • [22] Influence of stimulus size, intensity, & natural eye motion on small-field color perception
    Vanston, John Erik
    Boehm, Alexandra E.
    Tuten, William Scott
    Roorda, Austin John
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [23] Field Size Influence On the Electron and Photon Spectra Within Small MV Field Detectors
    Benmakhlouf, H.
    Andreo, P.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3433 - 3433
  • [24] A synthetic diamond detector as transfer dosimeter for Dw measurements in photon beams with small field sizes
    Pimpinella, M.
    Ciancaglioni, I.
    Consorti, R.
    Di Venanzio, C.
    Guerra, A. S.
    Petrucci, A.
    Stravato, A.
    Verona-Rinati, G.
    [J]. METROLOGIA, 2012, 49 (05) : S207 - S210
  • [25] Is there a general Procedure for Optimizing the Beam Model in the TPS using standard Small-field Dosimetry for stereotactic Radiation?
    Kirchhefer, J.
    Gutzeit, A.
    Loot, K.
    Rohn, R.
    Waletzko, O.
    Block, A.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2022, 198 (SUPPL 1) : S135 - S136
  • [26] Performance of 3D diamond detectors in small field dosimetry: The impact of pixel size
    Kanxheri, Keida
    Talamonti, Cinzia
    Sciortino, Silvio
    Lagomarsino, Stefano
    Ionica, Maria
    Caprai, Mirco
    Moscatelli, Francesco
    Servoli, Leonello
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 102 : 73 - 78
  • [27] Verification of relative output factor measurement using Gafchromic films for small-field radiosurgery photon beams
    Abdullah, R.
    Sapeei, M. S.
    Shukor, N. S. A.
    Yusof, M. F. M.
    Mohamed, M.
    Idris, N. R. N.
    Yusoff, A. L.
    Zakaria, A.
    Aziz, M. Z. A.
    [J]. INTERNATIONAL NUCLEAR SCIENCE, TECHNOLOGY AND ENGINEERING CONFERENCE 2017 (INUSTEC2017), 2018, 298
  • [28] Determination of the small-field output factor for 6 MV photon beam using EGSnrc Monte Carlo
    Chuah, K. W.
    Aziz, Abdul M. Z.
    Jayamani, J.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2022, 47 (03) : 301 - 308
  • [29] Small-Field Dosimetry in Single-Isocenter Stereotactic Irradiation for Brain Metastases Using a Detector-Specific Field Output Correction Factor
    Ono, T.
    Nakamura, M.
    Uto, M.
    Mizowaki, T.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [30] Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size
    Bucciolini, M
    Buonamici, FB
    Mazzocchi, S
    De Angelis, C
    Onori, S
    Cirrone, GAP
    [J]. MEDICAL PHYSICS, 2003, 30 (08) : 2149 - 2154