Development of a long trace profiler in situ at National Synchrotron Radiation Research Center

被引:3
|
作者
Lin, Shang-Wei [1 ]
Wang, Duan-Jen [1 ]
Fu, Huang-Wen [1 ]
Tsai, Huang-Ming [1 ]
Hua, Chih-Yu [1 ]
Kuo, Chang-Yang [1 ,2 ]
Hsu, Ming-Ying [1 ]
Kao, Kai-Yang [1 ]
Yin, Gung-Chian [1 ]
Fung, Hok-Sum [1 ]
Perng, Shen-Yaw [1 ]
Chang, Chia-Feng [1 ]
机构
[1] Natl Synchrotron Radiat Res Ctr, Hsinchu 30076, Taiwan
[2] Max Planck Inst Chem Phys Solids, Nothnitzer Str 40, D-01187 Dresden, Germany
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2019年 / 90卷 / 02期
关键词
DISTORTION PROFILE; MIRROR;
D O I
10.1063/1.5055634
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To achieve an ultrahigh resolution of a beamline for soft X-rays at the Taiwan Photon Source (TPS), the profile of a highly precise grating is required at various curvatures. The slope error could be decreased to 0.1 mu rad (rms) at a thermal load with a specially designed bender having 25 actuators. In the meantime, a long-trace profiler (LTP) was developed in situ to monitor the grating profile under a thermal load; it consists of a moving optical head, an air-bearing slide, an adjustable stand, and a glass viewport on the vacuum chamber. In the design of this system, a test chamber with an interior mirror was designed to simulate the chamber in the beamline. To prevent an error induced from a commercial viewport, a precision glass viewport (150CF, flatness 1/150 lambda rms at 632.8 nm) was designed. The error induced from the slope error of the glass surface and the vacuum deformation was also simulated. The performance of the optical head of the LTP in situ (ISLTP) has been tested in the metrology laboratory. The sources of error of this LTP including the linearity and the glass viewport were corrected after the measurement. For the beamline measurement, an optical head was mounted outside the vacuum chamber; the measuring beam passed through the glass viewport to measure the grating profile in vacuum. The measurement of the LTP after correction of the above errors yielded a precision about 0.2 mu rad (rms). In a preliminary test, an ISLTP was used to measure the grating profile at soft X-ray beamline TPS45A. The measured profile was for the bending mechanism to optimize the slope profile. From the measured energy spectrum, the slope error of the grating was estimated with software for optical simulation to be about 0.3 mu rad (rms), consistent with our estimate of the ISLTP. In the future, it will be used to monitor the thermal bump under a large thermal load. In addition, an ISLTP was used to monitor the properties of optical elements-the twist and radius in the beamline during the installation phase. Published under license by AIP Publishing.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Network-based real-time radiation monitoring system in Synchrotron Radiation Research Center
    Sheu, RJ
    Wang, JP
    Chen, CR
    Liu, J
    Chang, FD
    Jiang, SH
    HEALTH PHYSICS, 2003, 85 (04): : 485 - 493
  • [42] THE INTERNATIONAL DEVELOPMENT OF SYNCHROTRON-RADIATION RESEARCH - A VIEW FROM JAPAN
    SASAKI, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 347 (1-3): : 9 - 13
  • [43] WIGGLER X-RAY BEAMLINES AT SYNCHROTRON-RADIATION RESEARCH-CENTER
    TSANG, KL
    LEE, CH
    JEAN, YC
    DANN, TE
    CHEN, JR
    DAMICO, KL
    OVERSLUIZEN, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1812 - 1814
  • [44] PROGRAMS OF NATIONAL CENTER FOR HEALTH SERVICES RESEARCH AND DEVELOPMENT - EVALUATION RESEARCH
    HUNTLEY, RR
    MEDICAL CARE, 1969, 7 (02) : 86 - 91
  • [45] Development of a sticker sealed microfluidic device for in situ analytical measurements using synchrotron radiation
    Neckel, Itamar T.
    de Castro, Lucas F.
    Callefo, Flavia
    Teixeira, Veronica C.
    Gobbi, Angelo L.
    Piazzetta, Maria H.
    de Oliveira, Ricardo A. G.
    Lima, Renato S.
    Vicente, Rafael A.
    Galante, Douglas
    Tolentino, Helio C. N.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [46] Development of a sticker sealed microfluidic device for in situ analytical measurements using synchrotron radiation
    Itamar T. Neckel
    Lucas F. de Castro
    Flavia Callefo
    Verônica C. Teixeira
    Angelo L. Gobbi
    Maria H. Piazzetta
    Ricardo A. G. de Oliveira
    Renato S. Lima
    Rafael A. Vicente
    Douglas Galante
    Helio C. N. Tolentino
    Scientific Reports, 11
  • [47] Modernization of the Vacuum System of Synchrotron Radiation Sources at the National Research Centre Kurchatov Institute
    Moseiko, N. I.
    Krylov, Yu. V.
    Moseiko, L. A.
    Odintsov, D. G.
    Semenov, B. I.
    Shirokov, A. V.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2012, 9 (4-5) : 456 - 460
  • [48] Modernization of the vacuum system of synchrotron radiation sources at the National Research Centre Kurchatov Institute
    N. I. Moseiko
    Yu. V. Krylov
    L. A. Moseiko
    D. G. Odintsov
    B. I. Semenov
    A. V. Shirokov
    Physics of Particles and Nuclei Letters, 2012, 9 (4-5) : 456 - 460
  • [49] Laser Additive Manufacturing of Metallic Functional Materials and In-Situ Synchrotron Radiation Research (Invited)
    Li, Guanqi
    Zhang, Dongsheng
    Zheng, Jiaxing
    Lue, Chao
    Liu, Wei
    Zhao, Xinqing
    Zhang, Bingbing
    Hou, Huilong
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2024, 51 (10):
  • [50] NATIONAL CENTER FOR HEALTH SERVICES RESEARCH AND DEVELOPMENT - AN OPPORTUNITY FOR PARTNERSHIP
    MCCARTHY, T
    JOURNAL OF MEDICAL EDUCATION, 1969, 44 (05): : 337 - &