Full-Scale Testing of a Viscoelastic Coupling Damper for High-Rise Building Applications and Comparative Evaluation of Different Numerical Models

被引:28
|
作者
Pant, Deepak R. [1 ,2 ]
Montgomery, Michael [1 ]
Christopoulos, Constantin [3 ]
机构
[1] Kinetica, 1235 Bay St,Suite 1004, Toronto, ON M5R 3K4, Canada
[2] Univ Toronto, Dept Civil Engn, 35 St George St, Toronto, ON M5S IA4, Canada
[3] Univ Toronto, Dept Civil Engn, Seism Resilience Infrastruct, 35 St George St, Toronto, ON M5S IA4, Canada
关键词
Full-scale testing; Numerical modeling; Viscoelastic damper; Wind and seismic loadings; SEISMIC ANALYSIS;
D O I
10.1061/(ASCE)ST.1943-541X.0002246
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Viscoelastic coupling dampers (VCDs) are used for the seismic and wind protection of tall buildings. In the past, several tests have been carried out on VCDs under severe loading conditions for concept validation purposes and different numerical models have been used for evaluating the performance of tall buildings with VCDs. Nonetheless, for practical applications understanding the performance of VCDs over a full range of demands including extremely small amplitudes of vibration, long-duration loading, and realistic well-defined design level seismic and wind events, as well as a comparative evaluation of different numerical models are needed. To address this research gap, a systematic study was carried out to understand the performance of VCDs based on full-scale tests and to assess the suitability of different numerical models in predicting their response. A range of displacement-controlled tests was carried out on a full-scale VCD specimen. Seismic loading was derived by considering both far-fault long-period long-duration ground motions as well as near-fault pulse-like ground motions that were developed based on a site-specific study and were scaled to represent the design earthquake (DE) and the risk-targeted maximum considered earthquake (MCER) levels for a real project. Long-duration wind loading of 6-h with 1-, 10-, 50-, and 500-year mean recurrence intervals (per Canadian practice) developed based on wind tunnel testing of another real project were used. The temperature rise in the specimen during the tests was measured using high-precision thermocouples embedded in the viscoelastic (VE) layers as well as an external thermal camera. The test results indicated well-defined force-deformation hystereses of the specimen at all levels of strain amplitudes including those at extremely small deformation amplitudes up to 2.5m of deformation. The temperature rise of the specimen was less than 1 degrees C and 4 degrees C, respectively for the earthquake and wind loadings representative of the real projects that were considered in this study. This temperature rise was found to be lower when compared with previous generations of VE materials, which were tested under loading representative of shorter buildings with higher fundamental frequencies. Finally, the accuracy of four different macroscopic numerical models with different degrees of complexities in simulating the test results was investigated. Different numerical models were found to be suitable for different loading conditions and recommendations are provided for practical nonlinear modeling of tall buildings with VE dampers.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Dynamic testing and evaluation of mass damper technology for high-rise buildings with state-of-the-art practice
    Shan J.
    Lu X.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 (03): : 1 - 10
  • [32] Energy-based numerical evaluation for seismic performance of a high-rise steel building
    Zhang, H. D.
    Wang, Y. F.
    STEEL AND COMPOSITE STRUCTURES, 2012, 13 (06): : 501 - 519
  • [33] Dynamic calibration of slab track models for railway applications using full-scale testing
    Sainz-Aja, J.
    Pombo, J.
    Tholken, D.
    Carrascal, I
    Polanco, J.
    Ferreno, D.
    Casado, J.
    Diego, S.
    Perez, A.
    Abdala Filho, J. E.
    Esen, A.
    Marolt Cebasek, T.
    Laghrouche, O.
    Woodward, P.
    COMPUTERS & STRUCTURES, 2020, 228
  • [34] Aerodynamic characteristics of square high-rise building models in different turbulent boundary layers
    Li S.
    Wang H.
    Lo Y.
    Luo Z.
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2020, 51 (06): : 1606 - 1614
  • [35] Numerical Simulation of Fire Smoke Spread in a Super High-Rise Building for Different Fire Scenarios
    Yi, Xin
    Lei, Changkui
    Deng, Jun
    Ma, Li
    Fan, Jing
    Liu, Yuanyuan
    Bai, Lei
    Shu, Chi-Min
    ADVANCES IN CIVIL ENGINEERING, 2019, 2019
  • [36] Comparison of wind pressure coefficients between wind tunnel experiments and full-scale measurements using operational data from an urban high-rise building
    Kikuchi, Takuro
    Ohtake, Kazuo
    Takahashi, Yoshimi
    Watanabe, Hiroki
    Hidari, Katsuaki
    Tanabe, Shin-ichi
    Nobe, Tatsuo
    BUILDING AND ENVIRONMENT, 2024, 252
  • [37] Comparative study of full-scale and model-scale wind pressure measurements on a gable roof low-rise building
    Li, J. C.
    Hu, S. Y.
    Li, Q. S.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2021, 208
  • [38] Numerical simulation of air flows in a full-scale ventilated room using different turbulence models
    Jiang, J. B.
    Wang, X.
    Zhang, Y.
    Livestock Environment VII, Proceedings, 2005, : 35 - 44
  • [39] AN APPRAISAL OF CURRENT METHODS OF DESIGNING HIGH-RISE BUILDINGS AGAINST DYNAMIC WIND FORCES, BASED ON FULL-SCALE MEASUREMENTS
    LAM, RP
    LAM, LCH
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1984, 77 (DEC): : 465 - 478
  • [40] Effect of different objective functions on control performance of tuned mass damper for a high-rise building considering soil–structure interaction
    Onur Araz
    Kasif Furkan Ozturk
    Tufan Cakir
    Archive of Applied Mechanics, 2022, 92 : 1413 - 1429