Numerical Simulation of Fire Smoke Spread in a Super High-Rise Building for Different Fire Scenarios

被引:14
|
作者
Yi, Xin [1 ,2 ]
Lei, Changkui [1 ]
Deng, Jun [1 ,2 ]
Ma, Li [1 ,2 ]
Fan, Jing [1 ]
Liu, Yuanyuan [1 ]
Bai, Lei [1 ,2 ]
Shu, Chi-Min [3 ]
机构
[1] Xian Univ Sci & Technol, Sch Safety Sci & Engn, Xian, Shaanxi, Peoples R China
[2] Shaanxi Key Lab Prevent & Control Coal Fire, Xian, Shaanxi, Peoples R China
[3] Natl Yunlin Univ Sci & Technol, Grad Sch Engn Sci & Technol, 123 Univ Rd,Sec 3, Touliu, Yunlin, Taiwan
关键词
D O I
10.1155/2019/1659325
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Research on fire spread in super high-rise buildings is crucial for identifying feasible methods of fire prevention and personnel evacuation. In this study, a fire spread model was established based on the fire dynamics simulator (FDS), and fire spread results were analyzed for a fire scenario in a single room under different conditions, a fire scenario in different functional places under the same conditions, and the spread of fire outside of the room. The results revealed that the critical time required for a fire to become a safety hazard in a shop, a restaurant, or an office was approximately 200s. The same type of fire reached the critical time required for a fire to become a safety hazard more quickly in an office than a restaurant or shop, regardless of whether the fire spread was caused by CO mass fraction or temperature. More attention should be paid to fire safety in office spaces in super high-rise buildings. Furthermore, compared with CO mass fraction and temperature, visibility was a more influential factor in determining the critical time required for fire to become a hazard, and smoke affected the adjacent open area in approximately 60s. In the event of a fire, the temperature of the staircase and its front chamber was always lower than the threshold temperature of 60 degrees C for human body tolerance.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Simulation on spread of fire smoke in the elevator shaft for a high-rise building
    Xia, Yunchun
    [J]. THEORETICAL AND APPLIED MECHANICS LETTERS, 2014, 4 (03)
  • [2] Simulation on spread of fire smoke in the elevator shaft for a high-rise building
    Yunchun Xia
    [J]. Theoretical & Applied Mechanics Letters, 2014, 4 (03) : 86 - 91
  • [3] Numerical Simulation of Smoke Movement in Vertical Shafts during a High-Rise Building Fire
    Zhang, Xutao
    Wang, Songling
    [J]. CIVIL ENGINEERING, ARCHITECTURE AND SUSTAINABLE INFRASTRUCTURE II, PTS 1 AND 2, 2013, 438-439 : 1824 - 1829
  • [4] Numerical simulation of smoke movement influence to evacuation in a high-rise residential building fire
    Yang Juntao
    Yang Yun
    Chen Ye
    [J]. 2012 INTERNATIONAL SYMPOSIUM ON SAFETY SCIENCE AND TECHNOLOGY, 2012, 45 : 727 - 734
  • [5] Simulation study on fire and evacuation of super high-rise commercial building
    Yan, Zheng
    Wang, Ying
    Chao, Longxiao
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2023, 52
  • [7] Numerical Computation and Analysis on the Flow Characteristics of Smoke in the Fire of High-rise Building
    Chang, Junming
    [J]. 2013 INTERNATIONAL CONFERENCE ON COMPUTER SCIENCES AND APPLICATIONS (CSA), 2013, : 799 - 802
  • [8] Simulation of fire and evacuation in high-rise building
    Xing Zhixiang
    Tang Yong
    [J]. 2012 INTERNATIONAL SYMPOSIUM ON SAFETY SCIENCE AND TECHNOLOGY, 2012, 45 : 705 - 709
  • [9] A high-rise building fire
    Craighead, G
    [J]. FOURTH CONFERENCE ON TALL BUILDINGS IN SEISMIC REGIONS, PROCEEDINGS: TALL BUILDINGS FOR THE 21ST CENTURY, 1997, : 427 - 428
  • [10] Study on Smoke Control Strategy in a High-rise Building Fire
    Yu, Yuan
    Chu, Yan-yan
    Liang, Dong
    [J]. 2013 INTERNATIONAL CONFERENCE ON PERFORMANCE-BASED FIRE AND FIRE PROTECTION ENGINEERING (ICPFFPE 2013), 2014, 71 : 145 - 152