Full-Scale Testing of a Viscoelastic Coupling Damper for High-Rise Building Applications and Comparative Evaluation of Different Numerical Models

被引:28
|
作者
Pant, Deepak R. [1 ,2 ]
Montgomery, Michael [1 ]
Christopoulos, Constantin [3 ]
机构
[1] Kinetica, 1235 Bay St,Suite 1004, Toronto, ON M5R 3K4, Canada
[2] Univ Toronto, Dept Civil Engn, 35 St George St, Toronto, ON M5S IA4, Canada
[3] Univ Toronto, Dept Civil Engn, Seism Resilience Infrastruct, 35 St George St, Toronto, ON M5S IA4, Canada
关键词
Full-scale testing; Numerical modeling; Viscoelastic damper; Wind and seismic loadings; SEISMIC ANALYSIS;
D O I
10.1061/(ASCE)ST.1943-541X.0002246
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Viscoelastic coupling dampers (VCDs) are used for the seismic and wind protection of tall buildings. In the past, several tests have been carried out on VCDs under severe loading conditions for concept validation purposes and different numerical models have been used for evaluating the performance of tall buildings with VCDs. Nonetheless, for practical applications understanding the performance of VCDs over a full range of demands including extremely small amplitudes of vibration, long-duration loading, and realistic well-defined design level seismic and wind events, as well as a comparative evaluation of different numerical models are needed. To address this research gap, a systematic study was carried out to understand the performance of VCDs based on full-scale tests and to assess the suitability of different numerical models in predicting their response. A range of displacement-controlled tests was carried out on a full-scale VCD specimen. Seismic loading was derived by considering both far-fault long-period long-duration ground motions as well as near-fault pulse-like ground motions that were developed based on a site-specific study and were scaled to represent the design earthquake (DE) and the risk-targeted maximum considered earthquake (MCER) levels for a real project. Long-duration wind loading of 6-h with 1-, 10-, 50-, and 500-year mean recurrence intervals (per Canadian practice) developed based on wind tunnel testing of another real project were used. The temperature rise in the specimen during the tests was measured using high-precision thermocouples embedded in the viscoelastic (VE) layers as well as an external thermal camera. The test results indicated well-defined force-deformation hystereses of the specimen at all levels of strain amplitudes including those at extremely small deformation amplitudes up to 2.5m of deformation. The temperature rise of the specimen was less than 1 degrees C and 4 degrees C, respectively for the earthquake and wind loadings representative of the real projects that were considered in this study. This temperature rise was found to be lower when compared with previous generations of VE materials, which were tested under loading representative of shorter buildings with higher fundamental frequencies. Finally, the accuracy of four different macroscopic numerical models with different degrees of complexities in simulating the test results was investigated. Different numerical models were found to be suitable for different loading conditions and recommendations are provided for practical nonlinear modeling of tall buildings with VE dampers.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] EVALUATION OF FUNDAMENTAL DYNAMIC CHARACTERISTICS AND SEISMIC RESPONSE CHARACTERISTICS OF HIGH-RISE DAMPED BUILDING WITH OIL DAMPER HAVING RELIEF LOAD
    Matsuzawa A.
    Hatada T.
    Nagano M.
    Journal of Structural and Construction Engineering, 2024, 89 (821): : 684 - 695
  • [42] Impacts of high-rise building on urban airflows and pollutant dispersion under different temperature stratifications: Numerical investigations
    Huang, Xiaohui
    Gao, Lizhen
    Guo, Dongpeng
    Yao, Rentai
    ATMOSPHERIC POLLUTION RESEARCH, 2021, 12 (03) : 100 - 112
  • [43] Dynamic performances of trigeneration systems using different prime movers for high-rise building application: A comparative study
    Fong, K. F.
    Lee, C. K.
    BUILDING SIMULATION, 2017, 10 (04) : 509 - 523
  • [44] Dynamic performances of trigeneration systems using different prime movers for high-rise building application: A comparative study
    K. F. Fong
    C. K. Lee
    Building Simulation, 2017, 10 : 509 - 523
  • [45] Effect of different objective functions on control performance of tuned mass damper for a high-rise building considering soil-structure interaction
    Araz, Onur
    Ozturk, Kasif Furkan
    Cakir, Tufan
    ARCHIVE OF APPLIED MECHANICS, 2022, 92 (04) : 1413 - 1429
  • [46] Innovative steel-glass components for high-performance building skins: testing of full-scale prototypes
    Hoffmeister B.
    Di Biase P.
    Richter C.
    Feldmann M.
    Glass Structures & Engineering, 2017, 2 (1) : 57 - 78
  • [47] Wind Effects of Super High-Rise Buildings in the Pearl River Delta of China Based on 10-Year Full-Scale Measurements
    Liu, Chunlei
    Xie, Zhuangning
    Yu, Xianfeng
    Zhang, Lele
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (02)
  • [48] Dynamic Vibration Characteristics Monitoring of High-Rise Buildings by Interferometric Real-Aperture Radar Technique: Laboratory and Full-Scale Tests
    Hu, Jiyuan
    Guo, Jiming
    Zhou, Lv
    Zhang, Shuai
    Chen, Ming
    Hang, Changjun
    IEEE SENSORS JOURNAL, 2018, 18 (15) : 6423 - 6431
  • [49] CFD simulation of the wind environment around an isolated high-rise building: An evaluation of SRANS, LES and DES models
    Liu, Jianlin
    Niu, Jianlei
    BUILDING AND ENVIRONMENT, 2016, 96 : 91 - 106
  • [50] Field testing and performance evaluation of AMD-controlled high-rise building structures with real-world validation
    Zhang, Hanqing
    Shan, Jiazeng
    Lu, Xilin
    JOURNAL OF BUILDING ENGINEERING, 2023, 80