Image-Quality Perception as a Function of Dose in Digital Radiography

被引:6
|
作者
Lehnert, Thomas [1 ]
Naguib, Nagy N. N. [1 ]
Korkusuz, Huedayi [1 ]
Bauer, Ralf W. [1 ]
Kerl, J. Matthias [1 ]
Mack, Martin G. [1 ]
Vogl, Thomas J. [1 ]
机构
[1] Clin Johann Wolfgang Goethe Univ Frankfurt, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
关键词
digital radiography; filtration; image quality; musculoskeletal imaging; skin entrance dose; RADIATION;
D O I
10.2214/AJR.10.6269
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this article is to determine the degree to which the skin entrance dose could be lowered, by adjusting exposure parameters and filtration, and the subsequent effect on readers' confidence levels of digital radiographs. MATERIALS AND METHODS. The study was prospectively performed on a cadaver. Digital radiographs of bones were evaluated and scored on a 9-point scale separately by four radiologists who were blinded to the types of filtration and doses used. The study entailed three phases: phase 1, random dose and filter; phase 2, fixed filter and varying radiation doses (100%, 75%, 50%, and 25% of the standard recommended dose); and phase 3, fixed dose and varying filtration (no filtration, aluminum filter, and aluminum-copper filter). Skin entrance dose was measured using a dosimeter placed on the skin. Differences in scores were tested using a Friedman test. RESULTS. The mean scores given to images with 100%, 75%, 50%, and 25% of the recommended standard dose were 6.18, 6.1, 5.11, and 4.07, respectively. No significant difference was noted between 100%- and 75%-dose images (p = 0.1). A significant difference (p < 0.0001) was noted when we compared the 100%- and 75%-dose images with the 50%- and 25%-dose images. The mean scores given for no filtration, aluminum filtration, and aluminum-copper filtration were 5.67, 5.43, and 5.18, respectively. No significant difference between no filtration and aluminum filtration (p = 0.411) was noted. A significant difference was detected between no filtration and aluminum-copper filtration (p = 0.012). The combination of an aluminum filter and a 75% standard dose achieved a 31.1% reduction in skin entrance dose. CONCLUSION. It is possible to achieve a 31.1% reduction in skin entrance dose for imaging bony structures by using 75% of the standard dose and aluminum filtration without significantly affecting image quality.
引用
收藏
页码:1399 / 1403
页数:5
相关论文
共 50 条
  • [1] Evaluation of image-quality characteristics of four detectors for digital radiography
    Pooley, RA
    Morin, RL
    Fetterly, KA
    RADIOLOGY, 2001, 221 : 462 - 462
  • [2] DIGITAL RADIOGRAPHY: IMAGE QUALITY AND RADIATION DOSE
    Seibert, J. Anthony
    HEALTH PHYSICS, 2008, 95 (05): : 586 - 598
  • [3] Optimization of Dose and Image Quality for Computed Radiography and Digital Radiography
    John E. Aldrich
    Emerenciana Duran
    Pat Dunlop
    John R. Mayo
    Journal of Digital Imaging, 2006, 19 : 126 - 131
  • [4] Optimization of dose and image quality for computed radiography and digital radiography
    Aldrich, JE
    Duran, E
    Dunlop, P
    Mayo, JR
    JOURNAL OF DIGITAL IMAGING, 2006, 19 (02) : 126 - 131
  • [5] Balance of required dose and image quality in digital radiography
    Uffmann, M.
    Schaefer-Prokop, C.
    Neitzel, U.
    RADIOLOGE, 2008, 48 (03): : 249 - 257
  • [6] Image quality and exposure dose in digital projection radiography
    Busch, HP
    Busch, S
    Decker, C
    Schilz, C
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (01): : 32 - 37
  • [7] Optimization of dose and image quality in pediatrics chest digital radiography
    Deevband, Mohammad Reza
    Rahmani, Fereshteh
    Bardar, Meisam Ebrahimi
    Ghorbani, Mahdi
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2021, 52 (03) : 443 - 449
  • [8] Dose reduction in digital chest radiography and perceived image quality
    Kroft, L. J. M.
    Veldkamp, W. J. H.
    Mertens, B. J. A.
    Van Delft, J-P A.
    Geleijns, J.
    BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (960): : 984 - 988
  • [9] Dose Optimization and Image Quality in Digital Radiography: A Review Article
    Barai, Juhi
    Tivaskar, Suhas
    Sable, Apeksha
    Luharia, Anurag
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 (03) : 1076 - 1080
  • [10] Dose optimization and image quality measurement in digital abdominal radiography
    Karal, Omer
    Tokgoz, Nazime
    RADIATION PHYSICS AND CHEMISTRY, 2023, 205