Image-Quality Perception as a Function of Dose in Digital Radiography

被引:6
|
作者
Lehnert, Thomas [1 ]
Naguib, Nagy N. N. [1 ]
Korkusuz, Huedayi [1 ]
Bauer, Ralf W. [1 ]
Kerl, J. Matthias [1 ]
Mack, Martin G. [1 ]
Vogl, Thomas J. [1 ]
机构
[1] Clin Johann Wolfgang Goethe Univ Frankfurt, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
关键词
digital radiography; filtration; image quality; musculoskeletal imaging; skin entrance dose; RADIATION;
D O I
10.2214/AJR.10.6269
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this article is to determine the degree to which the skin entrance dose could be lowered, by adjusting exposure parameters and filtration, and the subsequent effect on readers' confidence levels of digital radiographs. MATERIALS AND METHODS. The study was prospectively performed on a cadaver. Digital radiographs of bones were evaluated and scored on a 9-point scale separately by four radiologists who were blinded to the types of filtration and doses used. The study entailed three phases: phase 1, random dose and filter; phase 2, fixed filter and varying radiation doses (100%, 75%, 50%, and 25% of the standard recommended dose); and phase 3, fixed dose and varying filtration (no filtration, aluminum filter, and aluminum-copper filter). Skin entrance dose was measured using a dosimeter placed on the skin. Differences in scores were tested using a Friedman test. RESULTS. The mean scores given to images with 100%, 75%, 50%, and 25% of the recommended standard dose were 6.18, 6.1, 5.11, and 4.07, respectively. No significant difference was noted between 100%- and 75%-dose images (p = 0.1). A significant difference (p < 0.0001) was noted when we compared the 100%- and 75%-dose images with the 50%- and 25%-dose images. The mean scores given for no filtration, aluminum filtration, and aluminum-copper filtration were 5.67, 5.43, and 5.18, respectively. No significant difference between no filtration and aluminum filtration (p = 0.411) was noted. A significant difference was detected between no filtration and aluminum-copper filtration (p = 0.012). The combination of an aluminum filter and a 75% standard dose achieved a 31.1% reduction in skin entrance dose. CONCLUSION. It is possible to achieve a 31.1% reduction in skin entrance dose for imaging bony structures by using 75% of the standard dose and aluminum filtration without significantly affecting image quality.
引用
收藏
页码:1399 / 1403
页数:5
相关论文
共 50 条
  • [21] Digital radiography: The balance between image quality and required radiation dose
    Uffmann, Martin
    Schaefer-Prokop, Cornelia
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (02) : 202 - 208
  • [22] Effect of dose reduction in digital dental panoramic radiography on image quality
    Dannewitz, B
    Hassfeld, S
    Eickholz, P
    Mühling, J
    DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (01) : 50 - 55
  • [23] Image quality and dose management in digital radiography: A new paradigm for optimisation
    Busch, HP
    Faulkner, K
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 143 - 147
  • [24] A phantom study of image quality versus radiation dose for digital radiography
    Tung, C. J.
    Tsai, H. Y.
    Shi, M. Y.
    Huang, T. T.
    Yang, C. H.
    Chen, I. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 602 - 605
  • [25] Management of dose and quality in digital radiography
    Busch, HP
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (01): : 17 - 19
  • [26] Balancing Image Quality and Dose in Radiography
    Peck, D.
    Pasciak, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 480 - 480
  • [27] Image Acquisition and Quality in Digital Radiography
    Alexander, Shannon
    RADIOLOGIC TECHNOLOGY, 2016, 88 (01) : 53 - 66
  • [28] Image Quality in Digital Industrial Radiography
    Ewert, Uwe
    Zscherpel, Uwe
    Heyne, Klara
    Jechow, Mirko
    Bavendiek, Klaus
    MATERIALS EVALUATION, 2012, 70 (08) : 955 - 964
  • [29] Image Quality Optimization vs. Patient Dose in Digital Thoracic Radiography
    Perez-Diaz, M.
    Ruiz-Gonzalez, Y.
    Machin-Linares, L.
    Ely-Andrade, M.
    Barros-Saito, J. C.
    Khoury, H. J.
    Ventosa-Almeida, J. C.
    VI LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2014), 2014, 49 : 353 - 356
  • [30] IMAGE QUALITY OPTIMIZATION IN BREAST DIGITAL RADIOGRAPHY VS. PATIENT DOSE
    Bernardo, A.
    Perez-Diaz, M.
    Echevarria-Torres, W. J.
    Diaz-Amador, R.
    REVISTA CUBANA DE FISICA, 2018, 35 (1E): : E17 - E20