Diagnostic performance of automated plasma amyloid-β assays combined with pre-analytical immunoprecipitation

被引:7
|
作者
Klafki, Hans-W [1 ]
Vogelgsang, Jonathan [1 ,2 ]
Manuilova, Ekaterina [3 ]
Bauer, Chris [4 ]
Jethwa, Alexander [3 ]
Esselmann, Hermann [1 ]
Jahn-Brodmann, Anke [1 ]
Osterloh, Dirk [5 ]
Lachmann, Ingolf [5 ]
Breitling, Benedict [1 ]
Rauter, Carolin [1 ]
Hansen, Niels [1 ]
Bouter, Caroline [6 ]
Palme, Stefan [3 ]
Schuchhardt, Johannes [4 ]
Wiltfang, Jens [1 ,7 ,8 ]
机构
[1] Georg August Univ, Univ Med Ctr Goettingen UMG, Dept Psychiat & Psychotherapy, Von Siebold Str 5, D-37075 Gottingen, Germany
[2] McLean Hosp, Harvard Med Sch, Dept Psychiat, Translat Neurosci Lab, Belmont, MA 02478 USA
[3] Roche Diagnost GmbH, D-82377 Penzberg, Germany
[4] MicroDiscovery GmbH, Marienburger Str 1, D-10405 Berlin, Germany
[5] Roboscreen GmbH, Hohmannstr 7, D-04129 Leipzig, Germany
[6] Georg August Univ, Univ Med Ctr Goettingen UMG, Dept Nucl Med, D-37075 Gottingen, Germany
[7] German Ctr Neurodegenerat Dis DZNE, D-37075 Gottingen, Germany
[8] Univ Aveiro, Inst Biomed iBiMED, Dept Med Sci, Neurosci & Signaling Grp, P-3810193 Aveiro, Portugal
关键词
Alzheimer's disease; Biomarker assay; Plasma Amyloid-beta 42/40; Immunoprecipitation; Pre-analytical sample workup; ALZHEIMERS-DISEASE; BIOMARKERS; PROTEIN;
D O I
10.1186/s13195-022-01071-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Measurements of the amyloid-beta (A beta) 42/40 ratio in blood plasma may support the early diagnosis of Alzheimer's disease and aid in the selection of suitable participants in clinical trials. Here, we compared the diagnostic performance of fully automated prototype plasma A beta 42/40 assays with and without pre-analytical sample workup by immunoprecipitation. Methods: A pre-selected clinical sample comprising 42 subjects with normal and 38 subjects with low cerebrospinal fluid (CSF) A beta 42/40 ratios was studied. The plasma A beta 42/40 ratios were determined with fully automated prototype Elecsys (R) immunoassays (Roche Diagnostics GmbH, Penzberg, Germany) by direct measurements in EDTA plasma or after pre-analytical A beta immunoprecipitation. The diagnostic performance for the detection of abnormal CSF A beta 42/40 was analyzed by receiver operating characteristic (ROC) analysis. In an additional post hoc analysis, a biomarker-supported clinical diagnosis was used as a second endpoint. Results: Pre-analytical immunoprecipitation resulted in a significant increase in the area under the ROC curve (AUC) from 0.73 to 0.88 (p = 0.01547) for identifying subjects with abnormal CSF A beta 42/40. A similar improvement in the diagnostic performance by pre-analytical immunoprecipitation was also observed when a biomarker-supported clinical diagnosis was used as a second endpoint (AUC increase from 0.77 to 0.92, p = 0.01576). Conclusions: Our preliminary observations indicate that pre-analytical A beta immunoprecipitation can improve the diagnostic performance of plasma A beta assays for detecting brain amyloid pathology. The findings may aid in the further development of blood-based immunoassays for Alzheimer's disease ultimately suitable for screening and routine use.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Pre-analytical stability of coagulation parameters in plasma stored at room temperature
    Linskens, E. A.
    Devreese, K. M. J.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 (03) : 292 - 303
  • [42] Effects of some pre-analytical conditions on the measurement of homocysteine and cysteine in plasma
    Zighetti, ML
    Chantarangkul, V
    Lombardi, R
    Lecchi, A
    Cattaneo, M
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2004, 42 (02) : 204 - 207
  • [43] Optimization of Pre-Analytical Handling to Maintain DNA Integrity in Diagnostic Papanicolaou Tests
    Schumacher, Sara
    Lauesgaard, Jacob Malchau
    Carlsson, Therese
    Linder, Anna
    Sundfeldt, Karin
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2025, 27 (03): : 199 - 208
  • [44] Pre analytical and analytical aspects of automated measurement of plasma lactate
    Valente, Cristina
    Moraschinelli, Irene
    Panteghini, Mauro
    Franzini, Carlo
    BIOCHIMICA CLINICA, 2005, 29 (5-6) : 501 - 506
  • [45] Pre-analytical and analytical variability in absolute quantitative MRM-based plasma proteomic studies
    Percy, Andrew J.
    Parker, Carol E.
    Borchers, Christoph H.
    BIOANALYSIS, 2013, 5 (22) : 2837 - 2856
  • [46] Pre-analytical phase: The automated ProTube device supports quality assurance in the phlebotomy process
    Piva, Elisa
    Tosato, Francesca
    Plebani, Mario
    CLINICA CHIMICA ACTA, 2015, 451 : 287 - 291
  • [47] The impact of pre-analytical variables in specimen presentation on test performance an the fully automated MDA 180(TM) coagulation analyzer
    Giles, A
    Dwyre, L
    Johnston, C
    BRITISH JOURNAL OF HAEMATOLOGY, 1996, 93 : 59 - 59
  • [48] Validation of soluble amyloid- precursor protein assays as diagnostic CSF biomarkers for neurodegenerative diseases
    van Doorn, Linda J. C. van Waalwijk
    Koel-Simmelink, Marleen J.
    Haussmann, Ute
    Klafki, Hans
    Struyfs, Hanne
    Linning, Philipp
    Knoelker, Hans-Joachim
    Twaalfhoven, Harry
    Kuiperij, H. Bea
    Engelborghs, Sebastiaan
    Scheltens, Philip
    Verbeek, Marcel M.
    Vanmechelen, Eugeen
    Wiltfang, Jens
    Teunissen, Charlotte E.
    JOURNAL OF NEUROCHEMISTRY, 2016, 137 (01) : 112 - 121
  • [49] INFLUENCE OF PRE-ANALYTICAL CONDITIONS ON PLASMA RIBAVIRIN CONCENTRATIONS DURING HCV THERAPY
    Gandia, Peggy
    Trancart, Stephanie
    Alric, Laurent
    Barange, Karl
    Nicot, Florence
    Izopet, Jacques
    Bonnet, Delphine
    SEraissol, Patrick
    Lavit, Michel
    Houin, Georges
    HEPATOLOGY, 2010, 52 (04) : 811A - 811A
  • [50] Pre-analytical factors affecting ascorbic and uric acid quantification in human plasma
    Zinellu, Angelo
    Sotgia, Salvatore
    Deiana, Luca
    Carru, Ciriaco
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2006, 67 (2-3): : 95 - 105