Pre-analytical stability of coagulation parameters in plasma stored at room temperature

被引:25
|
作者
Linskens, E. A. [1 ]
Devreese, K. M. J. [1 ]
机构
[1] Ghent Univ Hosp, Dept Clin Chem Microbiol & Immunol, Coagulat Lab, Ghent, Belgium
关键词
coagulation parameters; haemostasis; pre-analytical phase; stability; storage; PARTIAL THROMBOPLASTIN TIME; VON-WILLEBRAND-FACTOR; PROTHROMBIN TIME; FACTOR-VIII; D-DIMER; STORAGE; FIBRINOGEN; VARIABLES; SAMPLES;
D O I
10.1111/ijlh.12784
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Haemostasis testing is influenced by many pre-analytical variables, such as storage time and temperature, which can affect the stability of coagulation factors and influence the results of coagulation assays. We investigated the stability of haemostasis tests after storage of aliquoted plasma at RT, including the variability of measurement principle and reagent used for determination. Methods: Blood samples from 20 healthy volunteers were obtained, processed to PPP and aliquoted. Aliquots were stored at RT for 0 hour, 2 hours, 4 hours, 6 hours, 8 hours, 12 hours, 24 hours and 48 hours. PT, aPTT, fibrinogen, D-Dimers and coagulation factors (FII, FV, FVII, FX, FVIII, FIX, FXI, FXII) were determined by STA-R Max (R) and ACL-TOP (R). VWF:Ag and vWF:RCo were determined by AcuStar (R). Clinically relevant changes, compared to the initial measurement, were denoted as a percentage change of > 10% according to the 99% CI. Results: For both analysers, a clinically relevant change of > 10% was observed for FV after 2 hours, FVIII after 4 hours and for aPTT, FII, FVII, FX and FXII after 48 hours of storage at RT. Statistically significant, but no clinically relevant differences were observed after 48-hours storage for PT, fibrinogen and FIX. D-Dimers, FXI, vWF: Ag and vWF: RCo were found stable up to 48 hours at RT. Conclusion: Overall, compared to the limits given by the current CLSI guidelines, for most coagulation parameters investigated in this study a longer storage period could be accepted. Time intervals for FVIII and FV dosage were shorter than recommended by the CLSI guidelines. For PT determination, our findings were consistent.
引用
收藏
页码:292 / 303
页数:12
相关论文
共 50 条
  • [1] Pre-Analytical Stability of Coagulation Parameters in Plasma
    Linskens, Eleni Anabel
    Devreese, Katrien
    BLOOD, 2017, 130
  • [2] Pre-analytical stability of the plasma proteomes based on the storage temperature
    Pasella, Sara
    Baralla, Angela
    Canu, Elisabetta
    Pinna, Sara
    Vaupel, James
    Deiana, Marta
    Franceschi, Claudio
    Baggio, Giovannella
    Zinellu, Angelo
    Sotgia, Salvatore
    Castaldo, Giuseppe
    Carru, Ciriaco
    Deiana, Luca
    PROTEOME SCIENCE, 2013, 11
  • [3] Pre-analytical stability of the plasma proteomes based on the storage temperature
    Sara Pasella
    Angela Baralla
    Elisabetta Canu
    Sara Pinna
    James Vaupel
    Marta Deiana
    Claudio Franceschi
    Giovannella Baggio
    Angelo Zinellu
    Salvatore Sotgia
    Giuseppe Castaldo
    Ciriaco Carru
    Luca Deiana
    Proteome Science, 11
  • [4] Pre-analytical stability of sorbitol dehydrogenase in equine heparinized plasma
    Fouch, N.
    Oesch, S.
    Gerber, V.
    Richter, H.
    Howard, J.
    Peters, L. M.
    VETERINARY JOURNAL, 2021, 274
  • [5] Pre-analytical variability in coagulation measurements.
    Guidi, G
    Poli, G
    Lippi, G
    CLINICAL CHEMISTRY, 2004, 50 (06) : A182 - A183
  • [6] Extended Pre-Analytical Stability Validation for Coagulation Tests in Brazilian Clinical Laboratory
    Canali, D.
    Fijita, A.
    Sluzula, M.
    Vieira, L.
    Nakatani, S.
    Colombini, M.
    Silva, C.
    Dias, C.
    Lopes, A.
    CLINICAL CHEMISTRY, 2024, 70
  • [7] Coagulation testing: influence of blood collection tube and pre-analytical storage temperature
    Kleinegris, M. C. F.
    Loeffen, R.
    van der Meer, F. J. M.
    Reitsma, P. H.
    Loubele, S. T. B. G.
    Spronk, H. M. H.
    ten Cate, H.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 127 - 127
  • [8] Pre-analytical errors in coagulation testing: a case series
    Mahto, Mala
    Kumar, Visesh
    Banerjee, Ayan
    Kumar, Sushil
    Kumar, Anurag
    DIAGNOSIS, 2024, 11 (01) : 114 - 119
  • [9] Pre-analytical routines in coagulation testing: are guidelines followed?
    Kristoffersen, A-H
    Stavelin, A., V
    Vannes, S.
    Kristensen, G. B.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 18 - 18
  • [10] Pre-analytical stability of selected biochemical analytes in serum of horses and oxen stored at -20°C
    Megerssa, Yoseph Cherinet
    Gari, Fikru Regassa
    VETERINARY MEDICINE AND SCIENCE, 2024, 10 (02)