Pre-analytical stability of coagulation parameters in plasma stored at room temperature

被引:25
|
作者
Linskens, E. A. [1 ]
Devreese, K. M. J. [1 ]
机构
[1] Ghent Univ Hosp, Dept Clin Chem Microbiol & Immunol, Coagulat Lab, Ghent, Belgium
关键词
coagulation parameters; haemostasis; pre-analytical phase; stability; storage; PARTIAL THROMBOPLASTIN TIME; VON-WILLEBRAND-FACTOR; PROTHROMBIN TIME; FACTOR-VIII; D-DIMER; STORAGE; FIBRINOGEN; VARIABLES; SAMPLES;
D O I
10.1111/ijlh.12784
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Haemostasis testing is influenced by many pre-analytical variables, such as storage time and temperature, which can affect the stability of coagulation factors and influence the results of coagulation assays. We investigated the stability of haemostasis tests after storage of aliquoted plasma at RT, including the variability of measurement principle and reagent used for determination. Methods: Blood samples from 20 healthy volunteers were obtained, processed to PPP and aliquoted. Aliquots were stored at RT for 0 hour, 2 hours, 4 hours, 6 hours, 8 hours, 12 hours, 24 hours and 48 hours. PT, aPTT, fibrinogen, D-Dimers and coagulation factors (FII, FV, FVII, FX, FVIII, FIX, FXI, FXII) were determined by STA-R Max (R) and ACL-TOP (R). VWF:Ag and vWF:RCo were determined by AcuStar (R). Clinically relevant changes, compared to the initial measurement, were denoted as a percentage change of > 10% according to the 99% CI. Results: For both analysers, a clinically relevant change of > 10% was observed for FV after 2 hours, FVIII after 4 hours and for aPTT, FII, FVII, FX and FXII after 48 hours of storage at RT. Statistically significant, but no clinically relevant differences were observed after 48-hours storage for PT, fibrinogen and FIX. D-Dimers, FXI, vWF: Ag and vWF: RCo were found stable up to 48 hours at RT. Conclusion: Overall, compared to the limits given by the current CLSI guidelines, for most coagulation parameters investigated in this study a longer storage period could be accepted. Time intervals for FVIII and FV dosage were shorter than recommended by the CLSI guidelines. For PT determination, our findings were consistent.
引用
收藏
页码:292 / 303
页数:12
相关论文
共 50 条
  • [21] Effect of temperature on presepsin pre-analytical stability in biological fluids of preterm and term newborns
    D'Adamo, Ebe
    Botondi, Valentina
    Falconio, Luigi
    Giardinelli, Giustina
    Di Gregorio, Patrizia
    Caputi, Sergio
    Sinjari, Bruna
    Trubiani, Oriana
    Traini, Tonino
    Gazzolo, Francesca
    Strozzi, Maria Chiara
    Maconi, Antonio
    Gazzolo, Diego
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (05) : 1011 - 1016
  • [22] Effects of pre-analytical storage time, temperature, and freeze-thaw times on coagulation factors activities in citrate-anticoagulated plasma
    Zhao, Ying
    Feng, Guofang
    Feng, Limin
    ANNALS OF TRANSLATIONAL MEDICINE, 2018, 6 (23)
  • [23] Influence of pre-analytical conditions on plasma ribavirin concentrations
    Gandia, Peggy
    Trancart, Stephanie
    Nicot, Florence
    Barange, Karl
    Alric, Laurent
    Izopet, Jacques
    Seraissol, Patrick
    Lavit, Michel
    Houin, Georges
    ARZNEIMITTEL-FORSCHUNG-DRUG RESEARCH, 2010, 60 (10): : 636 - 639
  • [24] Effect of pre-analytical variables on coagulation tests in hepatitis B patients
    Yao, Jinmei
    Lv, Guocai
    BLOOD COAGULATION & FIBRINOLYSIS, 2014, 25 (07) : 761 - 764
  • [25] Pre-analytical and analytical aspects of EDTA-plasma iron measurement
    Leuenberger, Nicolas
    Baume, Norbert
    Robinson, Neil
    Saugy, Martial
    DRUG TESTING AND ANALYSIS, 2016, 8 (10) : 1077 - 1079
  • [26] Prevalence and type of pre-analytical problems for inpatients samples in coagulation laboratory
    Salvagno, Gian L.
    Lippi, Giuseppe
    Bassi, Antonella
    Poli, Giovanni
    Guidi, Gian C.
    JOURNAL OF EVALUATION IN CLINICAL PRACTICE, 2008, 14 (02) : 351 - 353
  • [27] Pre-analytical Variables in Coagulation Testing Associated With Diagnostic Errors in Hemostasis
    Favaloro, Emmanuel J.
    Funk, Dorothy M.
    Lippi, Giuseppe
    LABMEDICINE, 2012, 43 (02): : 54 - 60
  • [28] Pre-analytical parameters have significant impacts on VEGF levels measured from human plasma
    Walz, Johanna Madeleine
    Boehringer, Daniel
    Deissler, Heidrun L.
    Heiduschka, Peter
    Klettner, Alexa
    Krohne, Tim U.
    Ziemssen, Focke
    Stahl, Andreas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [29] Pre-Analytical Parameters Affecting Vascular Endothelial Growth Factor Measurement in Plasma: Identifying Confounders
    Walz, Johanna M.
    Boehringer, Daniel
    Deissler, Heidrun L.
    Faerber, Lothar
    Goepfert, Jens C.
    Heiduschka, Peter
    Kleeberger, Susannah M.
    Klettner, Alexa
    Krohne, Tim U.
    Schneiderhan-Marra, Nicole
    Ziemssen, Focke
    Stahl, Andreas
    PLOS ONE, 2016, 11 (01):
  • [30] Author Correction: Seven day pre-analytical stability of serum and plasma neurofilament light chain
    Patrick Altmann
    Markus Ponleitner
    Paulus Stefan Rommer
    Helmuth Haslacher
    Patrick Mucher
    Fritz Leutmezer
    Axel Petzold
    Christoph Wotawa
    Rupert Lanzenberger
    Thomas Berger
    Henrik Zetterberg
    Gabriel Bsteh
    Scientific Reports, 12