Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures

被引:46
|
作者
Mugnai, Raffaele [1 ]
Tarallo, Luigi [1 ]
Capra, Francesco
Catani, Fabio [1 ]
机构
[1] Modena Univ Hosp, Orthopaed & Traumatol Dept, Via Pietro Giardini 1355, I-41126 Modena, MO, Italy
关键词
Distal radius; Plate; Bending stiffness; Load to failure; Biomechanical; Material; ORTHOPEDIC-SURGERY; COMPOSITE-MATERIAL; INTERNAL-FIXATION; SHAFT FRACTURES; PLASTIC PLATES; SCREW DESIGN; BONE; IMPLANTS; COMPRESSION; STABILITY;
D O I
10.1016/j.otsr.2018.05.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: As the popularity of volar locked plate fixation for distal radius fractures has increased, so have the number and variety of implants, including variations in plate design, the size and angle of the screws, the locking screw mechanism, and the material of the plates. Hypothesis: Carbon-fiber reinforced polyetheretherketone (CFR-PEEK) plate features similar biomechanical properties to metallic plates, representing, therefore, an optimal alternative for the treatment of distal radius fractures. Materials and Methods: Three different materials-composed plates were evaluated: stainless steel volar lateral column (Zimmer); titanium DVR (Hand Innovations); CFR-PEEK DiPHOS-RM (Lima Corporate). Six plates for each type were implanted in sawbones and an extra-articular rectangular osteotomy was created. Three plates for each material were tested for load to failure and bending stiffness in axial compression. Moreover, 3 constructs for each plate were evaluated after dynamically loading for 6000 cycles of fatigue. Results: The mean bending stiffness pre-fatigue was significantly higher for the stainless steel plate. The titanium plate yielded the higher load to failure both pre and post fatigue. After cyclic loading, the bending stiffness increased by a mean of 24% for the stainless steel plate; 33% for the titanium; and 17% for the CFR-PEEK plate. The mean load to failure post-fatigue increased by a mean of 10% for the stainless steel and 14% for CFR-PEEK plates, whereas it decreased ( -16%) for the titanium plate. Statistical analysis between groups reported significant values (p < 001) for all comparisons except for Hand Innovations vs. Zimmer bending stiffness post fatigue (p = .197). Discussion: The significant higher load to failure of the titanium plate, makes it indicated for patients with higher functional requirements or at higher risk of trauma in the post-operative period. The CFR-PEEK plate showed material-specific disadvantages, represented by little tolerance to plastic deformation, and lower load to failure. (C) 2018 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:877 / 882
页数:6
相关论文
共 50 条
  • [31] Functional Outcomes in Volar-Displaced Distal Radius Fractures Patients with Marginal Rim Fragment Treated by Volar Distal Locking Plates
    Naito, Kiyohito
    Sugiyama, Yoichi
    Kinoshita, Mayuko
    Obata, Hiroyuki
    Goto, Kenji
    Nagura, Nana
    Iwase, Yoshiyuki
    Obayashi, Osamu
    Kaneko, Kazuo
    JOURNAL OF HAND AND MICROSURGERY, 2019, 11 (02) : 100 - 105
  • [32] Comparison of different distal radius dorsal and volar fracture fixation plates: A biomechanical study
    Osada, D
    Viegas, SF
    Shah, MA
    Morris, RP
    Patterson, RM
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (01): : 94 - 104
  • [33] CARBON-FIBER REINFORCED PLASTIC (CFRP) PLATES VERSUS STAINLESS-STEEL DYNAMIC COMPRESSION PLATES IN THE TREATMENT OF FRACTURES OF THE TIBIAE IN DOGS
    SKIRVING, AP
    DAY, R
    MACDONALD, W
    MCLAREN, R
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1987, (224) : 117 - 124
  • [34] Outcomes of minimally invasive plate osteosynthesis (MIPO) with volar locking plates in distal radius fractures: A review
    Liverneaux, P.
    Ichihara, S.
    Facca, S.
    Diaz, J. J. Hidalgo
    HAND SURGERY & REHABILITATION, 2016, 35 : S80 - S85
  • [35] The Effects of Screw Length on Stability of Simulated Osteoporotic Distal Radius Fractures Fixed With Volar Locking Plates
    Wall, Lindley B.
    Brodt, Michael D.
    Silva, Matthew J.
    Boyer, Martin I.
    Calfee, Ryan P.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (03): : 446 - 453
  • [36] Flexor tendon complications in comminuted distal radius fractures treated with anatomic volar rim locking plates
    Kara, Adnan
    Celik, Haluk
    Oc, Yunus
    Uzun, Metin
    Erdil, Mehmet
    Tetik, Cihangir
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2016, 50 (06) : 665 - 669
  • [37] A meta-analysis comparing volar locking plates and cast immobilization for distal radius fractures in the elderly
    Yang, Jingyi
    Li, Yating
    Li, Xiaoyan
    Wulan, Nari
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [38] Characteristics of two different locking compression plates in the volar fixation of complex articular distal radius fractures
    von Recum, J.
    Matschke, S.
    Jupiter, J. B.
    Ring, D.
    Souer, J-S.
    Huber, M.
    Audige, L.
    BONE & JOINT RESEARCH, 2012, 1 (06): : 111 - 117
  • [39] EXTENSOR POLLICIS LONGUS TENDON RUPTURES AFTER THE USE OF VOLAR LOCKING PLATES FOR DISTAL RADIUS FRACTURES
    Zenke, Yukichi
    Sakai, Akinori
    Oshige, Toshihisa
    Moritani, Shiro
    Menuki, Kunitaka
    Yamanaka, Yoshiaki
    Furukawa, Kayoko
    Nakamura, Toshitaka
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2013, 18 (02): : 169 - 173
  • [40] Biomechanical Comparison of Osteoporotic Distal Radius Fractures Fixed by Distal Locking Screws with Different Length
    Liu, Xiong
    Wu, Wei-dong
    Fang, Ya-feng
    Zhang, Mei-chao
    Huang, Wen-hua
    PLOS ONE, 2014, 9 (07):