Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study

被引:233
|
作者
Leipsic, Jonathon [1 ,2 ,7 ]
LaBounty, Troy M. [3 ]
Heilbron, Brett [2 ,7 ]
Min, James K. [3 ,4 ]
Mancini, G. B. John [5 ]
Lin, Fay Y. [3 ]
Taylor, Carolyn [2 ,7 ]
Dunning, Allison [3 ]
Earls, James P. [6 ]
机构
[1] St Pauls Hosp, Dept Med Imaging, Vancouver, BC V6Y 126, Canada
[2] Univ British Columbia, Dept Med, Div Cardiol, Vancouver, BC, Canada
[3] New York Presbyterian Hosp, Weill Cornell Med Coll, Div Cardiol, Dept Med, New York, NY USA
[4] New York Presbyterian Hosp, Weill Cornell Med Coll, Dept Radiol, New York, NY USA
[5] Univ British Columbia, Dept Med, Div Cardiol, Vancouver, BC, Canada
[6] Fairfax Radiol Consultants, Fairfax, VA USA
[7] Univ British Columbia, Dept Radiol, Div Cardiol, Vancouver, BC, Canada
关键词
adaptive statistical iterative reconstruction; coronary CT angiography; iterative reconstruction; radiation dose; CARDIAC COMPUTED-TOMOGRAPHY; IMPROVED IMAGE QUALITY; HELICAL CT; RADIOLOGY; ALGORITHM; COMMITTEE; EXPOSURE; HEART;
D O I
10.2214/AJR.10.4288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to assess the impact of Adaptive Statistical Iterative Reconstruction (ASIR) on radiation dose and study quality for coronary CT angiography (CTA). SUBJECTS AND METHODS. We prospectively evaluated 574 consecutive patients undergoing coronary CTA at three centers. Comparisons were performed between consecutive groups initially using filtered back projection (FBP) (n = 331) and subsequently ASIR (n = 243) with regard to patient and scan characteristics, radiation dose, and diagnostic study quality. RESULTS. There was no difference between groups in the use of prospective gating, tube voltage, or scan length. The examinations performed using ASIR had a lower median tube current than those obtained using FBP (median [interquartile range], 450 mA [350-600] vs 650 mA [531-750], respectively; p < 0.001). There was a 44% reduction in the median radiation dose between the FBP and ASIR cohorts (4.1 mSv [2.3-5.2] vs 2.3 mSv [1.9-3.5]; p < 0.001). After adjustment for scan settings, ASIR was associated with a 27% reduction in radiation dose compared with FBP (95% CI, 21-32%; p < 0.001). Despite the reduced current, ASIR was not associated with a difference in adjusted signal, noise, or signal-to-noise ratio (p = not significant). No differences existed between FBP and ASIR for interpretability per coronary artery (98.5% vs 99.3%, respectively; p = 0.12) or per patient (96.1% vs 97.1%, p = 0.65). CONCLUSION. ASIR enabled reduced tube current and lower radiation dose in comparison with FBP, with preserved signal, noise, and study interpretability, in a large multicenter cohort. ASIR represents a new technique to reduce radiation dose in coronary CTA studies.
引用
收藏
页码:655 / 660
页数:6
相关论文
共 50 条
  • [41] Feasibility Study of Radiation Dose Reduction in Adult Female Pelvic CT Scan with Low Tube-Voltage and Adaptive Statistical Iterative Reconstruction
    Wang, Xinlian
    He, Wen
    Chen, Jianghong
    Hu, Zhihai
    Zhao, Liqin
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (05) : 1047 - 1055
  • [42] Submillisievert coronary computed tomography angiography using adaptive statistical iterative reconstruction - a new reality
    Heilbron, Brett
    Leipsic, Jonathon
    CANADIAN JOURNAL OF CARDIOLOGY, 2010, 26 (01) : 35 - 36
  • [43] Radiation Dose Reduction with Hybrid Iterative Reconstruction for Pediatric CT
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Shenoy-Bhangle, Anuradha S.
    Saini, Aashna
    Gervais, Debra A.
    Westra, Sjirk J.
    Thrall, James H.
    RADIOLOGY, 2012, 263 (02) : 537 - 546
  • [44] Radiation Dose Reduction at Multidetector CT with Adaptive Statistical Iterative Reconstruction for Evaluation of Urolithiasis: How Low Can We Go?
    Kulkarni, Naveen M.
    Uppot, Raul N.
    Eisner, Brian H.
    Sahani, Dushyant V.
    RADIOLOGY, 2012, 265 (01) : 158 - 166
  • [45] Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: An intra-individual comparison
    Lee, Seung Hyun
    Kim, Myung-Joon
    Yoon, Choon-Sik
    Lee, Mi-Jung
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : E938 - E943
  • [46] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Park, Eun-Ah
    Lee, Whal
    Kim, Kwang Woo
    Kim, Kwang Gi
    Thomas, Allmendinger
    Chung, Jin Wook
    Park, Jae Hyung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (07): : 1775 - 1786
  • [47] Radiation dose and diagnostic image quality associated with iterative reconstruction in coronary CT angiography: A systematic review
    Abdullah, Kamarul Amin
    McEntee, Mark F.
    Reed, Warren
    Kench, Peter L.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (04) : 459 - 468
  • [48] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Eun-Ah Park
    Whal Lee
    Kwang Woo Kim
    Kwang Gi Kim
    Allmendinger Thomas
    Jin Wook Chung
    Jae Hyung Park
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1775 - 1786
  • [49] New scanning technique using Adaptive Statistical Iterative Reconstruction (ASIR) significantly reduced the radiation dose of cardiac CT
    Tumur, Odgerel
    Soon, Kean
    Brown, Fraser
    Mykytowycz, Marcus
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (03) : 292 - 296
  • [50] Evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction with the same group of patients
    Qi, L-P
    Li, Y.
    Tang, L.
    Li, Y-L
    Li, X-T
    Cui, Y.
    Sun, Y-S
    Zhang, X-P
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018): : E906 - E911