Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study

被引:233
|
作者
Leipsic, Jonathon [1 ,2 ,7 ]
LaBounty, Troy M. [3 ]
Heilbron, Brett [2 ,7 ]
Min, James K. [3 ,4 ]
Mancini, G. B. John [5 ]
Lin, Fay Y. [3 ]
Taylor, Carolyn [2 ,7 ]
Dunning, Allison [3 ]
Earls, James P. [6 ]
机构
[1] St Pauls Hosp, Dept Med Imaging, Vancouver, BC V6Y 126, Canada
[2] Univ British Columbia, Dept Med, Div Cardiol, Vancouver, BC, Canada
[3] New York Presbyterian Hosp, Weill Cornell Med Coll, Div Cardiol, Dept Med, New York, NY USA
[4] New York Presbyterian Hosp, Weill Cornell Med Coll, Dept Radiol, New York, NY USA
[5] Univ British Columbia, Dept Med, Div Cardiol, Vancouver, BC, Canada
[6] Fairfax Radiol Consultants, Fairfax, VA USA
[7] Univ British Columbia, Dept Radiol, Div Cardiol, Vancouver, BC, Canada
关键词
adaptive statistical iterative reconstruction; coronary CT angiography; iterative reconstruction; radiation dose; CARDIAC COMPUTED-TOMOGRAPHY; IMPROVED IMAGE QUALITY; HELICAL CT; RADIOLOGY; ALGORITHM; COMMITTEE; EXPOSURE; HEART;
D O I
10.2214/AJR.10.4288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to assess the impact of Adaptive Statistical Iterative Reconstruction (ASIR) on radiation dose and study quality for coronary CT angiography (CTA). SUBJECTS AND METHODS. We prospectively evaluated 574 consecutive patients undergoing coronary CTA at three centers. Comparisons were performed between consecutive groups initially using filtered back projection (FBP) (n = 331) and subsequently ASIR (n = 243) with regard to patient and scan characteristics, radiation dose, and diagnostic study quality. RESULTS. There was no difference between groups in the use of prospective gating, tube voltage, or scan length. The examinations performed using ASIR had a lower median tube current than those obtained using FBP (median [interquartile range], 450 mA [350-600] vs 650 mA [531-750], respectively; p < 0.001). There was a 44% reduction in the median radiation dose between the FBP and ASIR cohorts (4.1 mSv [2.3-5.2] vs 2.3 mSv [1.9-3.5]; p < 0.001). After adjustment for scan settings, ASIR was associated with a 27% reduction in radiation dose compared with FBP (95% CI, 21-32%; p < 0.001). Despite the reduced current, ASIR was not associated with a difference in adjusted signal, noise, or signal-to-noise ratio (p = not significant). No differences existed between FBP and ASIR for interpretability per coronary artery (98.5% vs 99.3%, respectively; p = 0.12) or per patient (96.1% vs 97.1%, p = 0.65). CONCLUSION. ASIR enabled reduced tube current and lower radiation dose in comparison with FBP, with preserved signal, noise, and study interpretability, in a large multicenter cohort. ASIR represents a new technique to reduce radiation dose in coronary CTA studies.
引用
收藏
页码:655 / 660
页数:6
相关论文
共 50 条
  • [31] Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography
    Sonja Gordic
    Lotus Desbiolles
    Martin Sedlmair
    Robert Manka
    André Plass
    Bernhard Schmidt
    Daniela B. Husarik
    Francesco Maisano
    Simon Wildermuth
    Hatem Alkadhi
    Sebastian Leschka
    European Radiology, 2016, 26 : 459 - 468
  • [32] Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography
    Gordic, Sonja
    Desbiolles, Lotus
    Sedlmair, Martin
    Manka, Robert
    Plass, Andre
    Schmidt, Bernhard
    Husarik, Daniela B.
    Maisano, Francesco
    Wildermuth, Simon
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2016, 26 (02) : 459 - 468
  • [33] Reducing dose in SPECT/CT using adaptive statistical iterative reconstruction technique
    Choi, Jinwook
    Choi, Hyeonjun
    Park, Chan Rok
    Cho, Sung Wook
    Kim, Jin Eui
    Lee, Jae Sung
    Lee, Dong Soo
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [34] Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT
    Gay, F.
    Pavia, Y.
    Pierrat, N.
    Lasalle, S.
    Neuenschwander, S.
    Brisse, H. J.
    EUROPEAN RADIOLOGY, 2014, 24 (01) : 102 - 111
  • [35] Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT
    F. Gay
    Y. Pavia
    N. Pierrat
    S. Lasalle
    S. Neuenschwander
    H. J. Brisse
    European Radiology, 2014, 24 : 102 - 111
  • [36] Dose reduction with iterative reconstruction for coronary CT angiography: a systematic review and meta-analysis
    Den Harder, Annemarie M.
    Willemink, Martin J.
    De Ruiter, Quirina M. B.
    De Jong, Pim A.
    Schilham, Arnold M. R.
    Krestin, Gabriel P.
    Leiner, Tim
    Budde, Ricardo P. J.
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1058):
  • [37] Radiation Dose Reduction With Chest Computed Tomography Using Adaptive Statistical Iterative Reconstruction Technique: Initial Experience
    Prakash, Priyanka
    Kalra, Mannudeep K.
    Digumarthy, Subba R.
    Hsieh, Jiang
    Pien, Homer
    Singh, Sarabjeet
    Gilman, Matthew D.
    Shepard, Jo-Anne O.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (01) : 40 - 45
  • [38] Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction
    Niesten, Joris M.
    van der Schaaf, Irene C.
    Riordan, Alan J.
    de Jong, Hugo W. A. M.
    Horsch, Alexander D.
    Eijspaart, Daniel
    Smit, Ewoud J.
    Mali, Willem P. T. M.
    Velthuis, Birgitta K.
    EUROPEAN RADIOLOGY, 2014, 24 (02) : 484 - 493
  • [39] Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction
    Joris M. Niesten
    Irene C. van der Schaaf
    Alan J. Riordan
    Hugo W. A. M. de Jong
    Alexander D. Horsch
    Daniel Eijspaart
    Ewoud J. Smit
    Willem P. T. M. Mali
    Birgitta K. Velthuis
    European Radiology, 2014, 24 : 484 - 493
  • [40] Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective
    Brady, S. L.
    Yee, B. S.
    Kaufman, R. A.
    MEDICAL PHYSICS, 2012, 39 (09) : 5520 - 5531