Diagnostic reference levels and achievable doses for common computed tomography examinations: Results from the Japanese nationwide dose survey

被引:48
|
作者
Matsunaga, Yuta [1 ,2 ]
Chida, Koichi [2 ]
Kondo, Yuya [3 ]
Kobayashi, Kenichi [4 ]
Kobayashi, Masanao [5 ]
Minami, Kazuyuki [5 ]
Suzuki, Shoichi [5 ]
Asada, Yasuki [5 ]
机构
[1] Nagoya Kyoritsu Hosp, Dept Imaging, Nagoya, Aichi, Japan
[2] Tohoku Univ, Grad Sch Med, Fac Hlth Sci, Dept Radiol Technol, Sendai, Miyagi, Japan
[3] Fujita Hlth Univ, Grad Sch Hlth Sci, Toyoake, Aichi, Japan
[4] Fujita Hlth Univ Hosp, Dept Radiol, Toyoake, Aichi, Japan
[5] Fujita Hlth Univ, Sch Hlth Sci, Fac Radiol Technol, Toyoake, Aichi, Japan
来源
BRITISH JOURNAL OF RADIOLOGY | 2019年 / 92卷 / 1094期
基金
日本学术振兴会;
关键词
TUBE VOLTAGE; CT;
D O I
10.1259/bjr.20180290
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To propose a new set of Japanese diagnostic reference levels (DRLs) and achievable doses (ADs) for 2017 and to verify the usefulness of Japanese DRLs (DRLs 2015) for CT, by investigating changes in the volume CT dose index (CTDIvol) from 2014 to 2017. Methods: Detailed information on the CT scan parameters used throughout Japan were obtained by questionnaire survey. The CTDIvol and dose-length product for the 11 commonest adult and 6 commonest paediatric CT examinations were surveyed and compared with 2014 data and DRLs 2015. Results: Evaluations of adult head (helical), and abdomen and pelvis without contrast agent, paediatric chest without contrast agent, and abdomen and pelvis without contrast agent showed a slightly lower mean CTDIvol in 2017 than in 2014 (t-test, p < 0.05). The interquartile range of CTDIvol for all 2017 examinations was lower than in 2014. Conclusions: This study verified the lower mean, 75th percentile, and interquartile range by investigating changes in the CTDIvol from 2014 to 2017. The DRLs 2015 contributed to CT radiation dose reduction. Advances in knowledge: The widespread implementation of iterative reconstruction algorithms and low-tube voltage in CT scanners is likely to facilitate further reduction in the CT radiation dose used in Japan. Although radiological technologists may require further education on appropriate CTDIvol and DLP usage, the DRLs 2015 greatly contributed to the reduction of the CT radiation dose used in Japan.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Diagnostic Reference Levels and Achievable Doses: Practical Clinical Implementation to Optimize CT Protocols and Dose
    Kanal, K.
    Moirano, J.
    Zamora, D.
    Butler, P.
    Morin, R.
    MEDICAL PHYSICS, 2017, 44 (06) : 3173 - 3174
  • [32] Changing Radiation Dose From Diagnostic Computed Tomography Examinations in Saskatchewan
    Dumaine, Chance S.
    Leswick, David A.
    Fladeland, Derek A.
    Lim, Hyun J.
    Toews, Lori J.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2012, 63 (03): : 183 - 191
  • [33] Systematic Review on Diagnostic Reference Levels for Computed Tomography Examinations in Radiation Therapy Planning
    Rao, Shreekripa
    Sharan, Krishna
    Sukumar, Suresh
    Chandraguthi, Srinidhi Gururajarao
    Nisha Dsouza, Rechal
    David, Leena R.
    Ravichandran, Sneha
    Uzun, Berna
    Kadavigere, Rajagopal
    Uzun Ozsahin, Dilber
    DIAGNOSTICS, 2023, 13 (06)
  • [34] Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels
    Erem, Geoffrey
    Ameda, Faith
    Otike, Caroline
    Olwit, William
    Mubuuke, Aloysius G.
    Schandorf, Cyril
    Kisolo, Akisophel
    Kawooya, Michael G.
    BMC MEDICAL IMAGING, 2022, 22 (01)
  • [35] Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels
    Geoffrey Erem
    Faith Ameda
    Caroline Otike
    William Olwit
    Aloysius G. Mubuuke
    Cyril Schandorf
    Akisophel Kisolo
    Michael G. Kawooya
    BMC Medical Imaging, 22
  • [36] Survey of clinical doses from computed tomography examinations in the Canadian province of Manitoba
    Elbakri, Idris A.
    Kirkpatrick, Iain D. C.
    RADIATION PROTECTION DOSIMETRY, 2013, 157 (04) : 525 - 535
  • [37] Diagnostic Reference Levels for conventional radiography and fluoroscopy in Austria: Results and updated National Diagnostic Reference Levels derived from a nationwide survey
    Wachabauer, David
    Roethlin, Florian
    Moshammer, Hanns Michael
    Homolka, Peter
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 113 : 135 - 139
  • [38] Survey of computed tomography scanners in Taiwan: Dose descriptors, dose guidance levels, and effective doses
    Tsai, H. Y.
    Tung, C. J.
    Yu, C. C.
    Tyan, Y. S.
    MEDICAL PHYSICS, 2007, 34 (04) : 1234 - 1243
  • [39] Diagnostic reference level of computed tomography examinations and need for dose optimization in Ondo State, Nigeria
    Oyedokun O.S.
    Arogunjo A.M.
    Fatukasi J.I.
    Egberongbe A.A.
    Oyedokun, Oluwakayode Samuel (osoyedokun@futa.edu.ng), 1600, Mashhad University of Medical Sciences (17): : 266 - 272
  • [40] The development of a diagnostic reference level on patient dose for head computed tomography angiography examinations in Korea
    Cho, Pyong-Kon
    RADIATION PROTECTION DOSIMETRY, 2013, 154 (04) : 505 - 509