Survey of clinical doses from computed tomography examinations in the Canadian province of Manitoba

被引:6
|
作者
Elbakri, Idris A. [1 ,2 ]
Kirkpatrick, Iain D. C. [2 ]
机构
[1] CancerCare Manitoba, Div Med Phys, Winnipeg, MB R3E 0V9, Canada
[2] Univ Manitoba, Dept Radiol, Winnipeg, MB R3E 0V9, Canada
关键词
CT; REDUCTION; CANCER;
D O I
10.1093/rpd/nct168
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this study was to document CT doses for common CT examinations performed throughout the province of Manitoba. Survey forms were sent out to all provincial CT sites. Thirteen out of sixteen (81 ) sites participated. The authors assessed scans of the brain, routine abdomenpelvis, routine chest, sinuses, lumbar spine, low-dose lung nodule studies, CT pulmonary angiograms, CT KUBs, CT colonographies and combination chestabdomenpelvis exams. Sites recorded scanner model, protocol techniques and patient and dose data for 100 consecutive patients who were scanned with any of the aforementioned examinations. Mean effective doses and standard deviations for the province and for individual scanners were computed. The KruskalWallis test was used to compare the variability of effective doses amongst scanners. The t test was used to compare doses and their provincial ranges between newer and older scanners and scanners that used dose saving tools and those that did not. Abdomenpelvis, chest and brain scans accounted for over 70 of scans. Their mean effective doses were 18.06.7, 13.26.4 and 3.01.0 mSv, respectively. Variations in doses amongst scanners were statistically significant. Most examinations were performed at 120 kVp, and no lower kVp was used. Dose variations due to scanner age and use of dose saving tools were not statistically significant. Clinical CT doses in Manitoba are broadly similar to but higher than those reported in other Canadian provinces. Results suggest that further dose reduction can be achieved by modifying scanning techniques, such as using lower kVp. Wide variation in doses amongst different scanners suggests that standardisation of scanning protocols can reduce patient dose. New technological advances, such as dose-reduction software algorithms, can be adopted to reduce patient dose.
引用
收藏
页码:525 / 535
页数:11
相关论文
共 50 条
  • [1] DOSES TO ADULT PATIENTS FROM COMPUTED TOMOGRAPHY EXAMINATIONS
    Domienik, Joanna
    Zmyslony, Marek
    MEDYCYNA PRACY, 2012, 63 (06) : 629 - 635
  • [2] THE CALCULATION OF ORGAN DOSES FROM COMPUTED-TOMOGRAPHY EXAMINATIONS
    ZANKL, M
    PANZER, W
    DREXLER, G
    RADIATION PROTECTION DOSIMETRY, 1992, 43 (1-4) : 237 - 239
  • [3] Computed tomography radiation doses for common computed tomography examinations: a nationwide dose survey in United Arab Emirates
    Abuzaid, Mohamed M.
    Elshami, Wiam
    Tekin, Huseyin Ozan
    Ghonim, Hatem
    Shawki, Mona
    Salama, Dina H.
    INSIGHTS INTO IMAGING, 2020, 11 (01)
  • [4] Computed tomography radiation doses for common computed tomography examinations: a nationwide dose survey in United Arab Emirates
    Mohamed M. Abuzaid
    Wiam Elshami
    Huseyin Ozan Tekin
    Hatem Ghonim
    Mona Shawki
    Dina H. Salama
    Insights into Imaging, 11
  • [5] A survey of the pediatric radiation doses during multiphase abdominal computed tomography examinations
    Sulieman, A.
    Adam, H.
    Tamam, N.
    Alkhorayef, M.
    Alhailiy, A.
    Alghamdi, S.
    Elnour, A.
    Alomair, O.
    Alashban, Y.
    Khandaker, M. U.
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [6] PATIENT DOSES FROM COMPUTED-TOMOGRAPHY IN MANITOBA FROM 1977 TO 1987
    HUDA, W
    SANDISON, GA
    LEE, TY
    BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (734): : 138 - 144
  • [7] Doses from cervical spine computed tomography (CT) examinations in the UK
    Holroyd, John R.
    Edyvean, Sue
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1085):
  • [8] Survey of paediatric imaging exposure from computed tomography examinations
    Alkhorayef, M.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167
  • [9] Current status of patient radiation doses from computed tomography examinations in Tanzania
    Ngaile, J. E.
    Msaki, P.
    Kazema, R.
    RADIATION PROTECTION DOSIMETRY, 2006, 121 (02) : 128 - 135
  • [10] Diagnostic reference levels and achievable doses for common computed tomography examinations: Results from the Japanese nationwide dose survey
    Matsunaga, Yuta
    Chida, Koichi
    Kondo, Yuya
    Kobayashi, Kenichi
    Kobayashi, Masanao
    Minami, Kazuyuki
    Suzuki, Shoichi
    Asada, Yasuki
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1094):