Survey of clinical doses from computed tomography examinations in the Canadian province of Manitoba

被引:6
|
作者
Elbakri, Idris A. [1 ,2 ]
Kirkpatrick, Iain D. C. [2 ]
机构
[1] CancerCare Manitoba, Div Med Phys, Winnipeg, MB R3E 0V9, Canada
[2] Univ Manitoba, Dept Radiol, Winnipeg, MB R3E 0V9, Canada
关键词
CT; REDUCTION; CANCER;
D O I
10.1093/rpd/nct168
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this study was to document CT doses for common CT examinations performed throughout the province of Manitoba. Survey forms were sent out to all provincial CT sites. Thirteen out of sixteen (81 ) sites participated. The authors assessed scans of the brain, routine abdomenpelvis, routine chest, sinuses, lumbar spine, low-dose lung nodule studies, CT pulmonary angiograms, CT KUBs, CT colonographies and combination chestabdomenpelvis exams. Sites recorded scanner model, protocol techniques and patient and dose data for 100 consecutive patients who were scanned with any of the aforementioned examinations. Mean effective doses and standard deviations for the province and for individual scanners were computed. The KruskalWallis test was used to compare the variability of effective doses amongst scanners. The t test was used to compare doses and their provincial ranges between newer and older scanners and scanners that used dose saving tools and those that did not. Abdomenpelvis, chest and brain scans accounted for over 70 of scans. Their mean effective doses were 18.06.7, 13.26.4 and 3.01.0 mSv, respectively. Variations in doses amongst scanners were statistically significant. Most examinations were performed at 120 kVp, and no lower kVp was used. Dose variations due to scanner age and use of dose saving tools were not statistically significant. Clinical CT doses in Manitoba are broadly similar to but higher than those reported in other Canadian provinces. Results suggest that further dose reduction can be achieved by modifying scanning techniques, such as using lower kVp. Wide variation in doses amongst different scanners suggests that standardisation of scanning protocols can reduce patient dose. New technological advances, such as dose-reduction software algorithms, can be adopted to reduce patient dose.
引用
收藏
页码:525 / 535
页数:11
相关论文
共 50 条
  • [21] ORGAN DOSES AND ASSOCIATED CANCER RISKS FOR COMPUTED TOMOGRAPHY EXAMINATIONS OF THE THORACIC REGION
    Majer, Marija
    Knezevic, Zeljka
    Popic, Jelena
    Hrsak, Hrvoje
    Miljanic, Saveta
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2018, 33 (01): : 100 - 105
  • [22] Radiation Doses from Computed tomography in Iraq
    Al-Kinani, Athab
    Saddam, Ahmad
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2014, 47 (01): : 114 - 124
  • [23] Canadian Computed Tomography Survey: National Diagnostic Reference Levels
    Wardlaw, Graeme M.
    Martel, Narine
    MEDICAL PHYSICS, 2016, 43 (08) : 4932 - 4933
  • [24] A METHOD FOR ESTIMATING EMBRYO DOSES RESULTING FROM COMPUTED TOMOGRAPHIC EXAMINATIONS
    PANZER, W
    ZANKL, M
    BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (742): : 936 - 939
  • [25] Reconstruction of organ doses for patients undergoing computed tomography examinations in Canada 1992-2019
    Lee, Choonsik
    Moroz, Brian
    Thome, Christopher
    Gaudreau, Katherine
    Emami, Pirouz
    Little, Mark P.
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (04) : 379 - 386
  • [26] Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand
    Neubauer, J.
    Neubauer, C.
    Gerstmair, A.
    Krauss, T.
    Reising, K.
    Zajonc, H.
    Kotter, E.
    Langer, M.
    Fiebich, M.
    Voigt, J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (05): : 488 - 493
  • [27] Dose-Length Product to Effective Dose Conversion Factors for Common Computed Tomography Examinations Based on Canadian Clinical Experience
    Elbakri, Idris A.
    Kirkpatrick, Kin D. C.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2013, 64 (01): : 15 - 17
  • [28] Findings from computed tomography examinations of Viking age skulls
    Carolina Bertilsson
    Eva Borg
    Maria Vretemark
    Henrik Lund
    BDJ Open, 11 (1)
  • [29] Determination of patient surface dose from computed tomography examinations
    Vekic, B
    Kovacevic, S
    RanogajecKomor, M
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C429 - C429
  • [30] Regional survey of image quality and radiation dose in computed tomography examinations in Saudi Arabia
    M. K. Saeed
    A. S. Alzoubi
    J. M. Al-Qahtani
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 279 - 283