Diagnostic reference levels and achievable doses for common computed tomography examinations: Results from the Japanese nationwide dose survey

被引:48
|
作者
Matsunaga, Yuta [1 ,2 ]
Chida, Koichi [2 ]
Kondo, Yuya [3 ]
Kobayashi, Kenichi [4 ]
Kobayashi, Masanao [5 ]
Minami, Kazuyuki [5 ]
Suzuki, Shoichi [5 ]
Asada, Yasuki [5 ]
机构
[1] Nagoya Kyoritsu Hosp, Dept Imaging, Nagoya, Aichi, Japan
[2] Tohoku Univ, Grad Sch Med, Fac Hlth Sci, Dept Radiol Technol, Sendai, Miyagi, Japan
[3] Fujita Hlth Univ, Grad Sch Hlth Sci, Toyoake, Aichi, Japan
[4] Fujita Hlth Univ Hosp, Dept Radiol, Toyoake, Aichi, Japan
[5] Fujita Hlth Univ, Sch Hlth Sci, Fac Radiol Technol, Toyoake, Aichi, Japan
来源
BRITISH JOURNAL OF RADIOLOGY | 2019年 / 92卷 / 1094期
基金
日本学术振兴会;
关键词
TUBE VOLTAGE; CT;
D O I
10.1259/bjr.20180290
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To propose a new set of Japanese diagnostic reference levels (DRLs) and achievable doses (ADs) for 2017 and to verify the usefulness of Japanese DRLs (DRLs 2015) for CT, by investigating changes in the volume CT dose index (CTDIvol) from 2014 to 2017. Methods: Detailed information on the CT scan parameters used throughout Japan were obtained by questionnaire survey. The CTDIvol and dose-length product for the 11 commonest adult and 6 commonest paediatric CT examinations were surveyed and compared with 2014 data and DRLs 2015. Results: Evaluations of adult head (helical), and abdomen and pelvis without contrast agent, paediatric chest without contrast agent, and abdomen and pelvis without contrast agent showed a slightly lower mean CTDIvol in 2017 than in 2014 (t-test, p < 0.05). The interquartile range of CTDIvol for all 2017 examinations was lower than in 2014. Conclusions: This study verified the lower mean, 75th percentile, and interquartile range by investigating changes in the CTDIvol from 2014 to 2017. The DRLs 2015 contributed to CT radiation dose reduction. Advances in knowledge: The widespread implementation of iterative reconstruction algorithms and low-tube voltage in CT scanners is likely to facilitate further reduction in the CT radiation dose used in Japan. Although radiological technologists may require further education on appropriate CTDIvol and DLP usage, the DRLs 2015 greatly contributed to the reduction of the CT radiation dose used in Japan.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Establishment of diagnostic reference levels in low-dose renal computed tomography
    Rawashdeh, Mohammad
    Saade, Charbel
    ACTA RADIOLOGICA, 2023, 64 (02) : 829 - 836
  • [42] Updated National Diagnostic Reference Levels and Achievable Doses for CT Protocols: A National Survey of Korean Hospitals
    Nam, Sora
    Park, Hyemin
    Kwon, Soonmu
    Cho, Pyong-kon
    Yoon, Yongsu
    Yoon, Sang-wook
    Kim, Jungsu
    TOMOGRAPHY, 2022, 8 (05) : 2450 - 2459
  • [43] Age-based diagnostic reference levels and achievable doses for paediatric CT: a survey in Shanghai, China
    Yang, Fanqiaochu
    Gao, Linfeng
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (02)
  • [44] Computed tomography diagnostic reference levels for adult brain, chest and abdominal examinations: A systematic review
    Garba, I.
    Zarb, F.
    McEntee, M. F.
    Fabri, S. G.
    RADIOGRAPHY, 2021, 27 (02) : 673 - 681
  • [45] Diagnostic reference levels of paediatric computed tomography examinations performed at a dedicated Australian paediatric hospital
    Bibbo, Giovanni
    Brown, Scott
    Linke, Rebecca
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (04) : 475 - 484
  • [46] Derivation of new diagnostic reference levels for neuro-paediatric computed tomography examinations in Switzerland
    Wagner, Franca
    Bize, Julie
    Racine, Damien
    Le Coultre, Regis
    Verdun, Francis
    Trueb, Philipp R.
    Treier, Reto
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (03) : 1013 - 1036
  • [47] LOCAL STUDY OF DIAGNOSTIC REFERENCE LEVELS FOR COMPUTED TOMOGRAPHY EXAMINATIONS OF ADULT PATIENTS IN IZMIR, TURKEY
    Yurt, Aysegul
    Ozsoykal, Ismail
    Kandemir, Recep
    Ada, Emel
    RADIATION PROTECTION DOSIMETRY, 2020, 190 (04) : 446 - 451
  • [48] Diagnostic reference levels for common pediatric computed tomography studies: A retrospective study.
    Khafaji, Mawya
    Barnawi, Rashid
    Amoudi, Salma
    Gabbani, Hassan
    Alhazmi, Rayan
    Ahyad, Rayan
    Alsafi, Khalid
    Saeedi, Khuld
    Salah, Hassan
    Tamam, Nissren
    Bradley, David
    Albahiti, Sarah
    Sulieman, Abdelmoneim
    RADIATION PHYSICS AND CHEMISTRY, 2024, 215
  • [49] ESTABLISHMENT OF LOCAL DIAGNOSTIC REFERENCE LEVELS FOR COMMON PROCEDURES OF COMPUTED TOMOGRAPHY IN YAZD PROVINCE
    Zamani, Hamed
    Masjedi, Hamidreza
    Omidi, Reza
    Hosein Zare, Mohammad
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (02) : 222 - 231
  • [50] PATIENT DOSES IN COMPUTED TOMOGRAPHY: AN ASSESSMENT OF LOCAL DIAGNOSTIC REFERENCE LEVELS IN A LARGE TEACHING HOSPITAL
    Hadnadjev, Darka R.
    Arandjic, Danijela D.
    Stojanovic, Sanja S.
    Ciraj-Bjelac, Olivera F.
    Bozovic, Predrag M.
    Stankovic, Jelena S.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2012, 27 (03): : 305 - 310