Graphical treatment simulation and automated collision detection for conformal and stereotactic radiotherapy treatment planning

被引:25
|
作者
Tsiakalos, MF [1 ]
Schrebmann, E [1 ]
Theodorou, K [1 ]
Kappas, C [1 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Rio 26500, Hellas, Greece
关键词
virtual simulation; collision detection; 3D conformal radiotherapy; treatment planning; room's eye view;
D O I
10.1118/1.1381552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work is to develop a "room's eye view" graphical simulation program with an automated collision detection option, to assist a treatment planning user to visualize the treatment setup checking at the same time the feasibility of his plan. The program simulates the treatment process using accurate three-dimensional graphical models of the gantry, table, and that of an average patient. This allows the use of any mechanical movement concerning the radiotherapy unit. The simulation of the mechanical movements and their limitations are according to IEC standards and thus compatible with any radiotherapy machine. Graphical methods for collision detection between the models guarantee speed and accuracy. The module simulates the treatment setup with accuracy better than 2 degrees for any tested case. When a collision takes place a warning message is displayed. In this paper a software tool is developed that can be used as a stand-alone program or embedded in any treatment planning system. The visualization of the treatment fields prior to treatment permits the geometric feasibility of the plan, thus adding one more step toward the automation of the treatment process. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:1359 / 1363
页数:5
相关论文
共 50 条
  • [1] Treatment planning for conformal stereotactic radiotherapy
    Kneschaurek, P
    Stärk, S
    Grosu, AL
    STRAHLENTHERAPIE UND ONKOLOGIE, 1999, 175 (Suppl 2) : 8 - 9
  • [2] Treatment planning for conformal stereotactic radiotherapy
    Peter Kneschaurek
    Sibylle Stärk
    Anca -Ligia Grosu
    Strahlentherapie und Onkologie, 1999, 175 : 8 - 9
  • [3] Immersive Visualization with Automated Collision Detection for Radiotherapy Treatment Planning
    Ward, J. W.
    Phillips, R.
    Williams, T.
    Shang, C.
    Page, L.
    Prest, C.
    Beavis, A. W.
    MEDICINE MEETS VIRTUAL REALITY 15: IN VIVO, IN VITRO, IN SILICO: DESIGNING THE NEXT IN MEDICINE, 2007, 125 : 491 - +
  • [4] Automated treatment planning for liver cancer stereotactic body radiotherapy
    He, Ling
    Peng, Xingchen
    Chen, Na
    Wei, Zhigong
    Wang, Jingjing
    Liu, Yingtong
    Xiao, Jianghong
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2023, 25 (11): : 3230 - 3240
  • [5] Automated treatment planning for liver cancer stereotactic body radiotherapy
    Ling He
    Xingchen Peng
    Na Chen
    Zhigong Wei
    Jingjing Wang
    Yingtong Liu
    Jianghong Xiao
    Clinical and Translational Oncology, 2023, 25 : 3230 - 3240
  • [6] The requirements in conformal radiotherapy treatment planning
    Schneider, P
    Leetz, HK
    RADIOTHERAPY AND ONCOLOGY, 1999, 52 (01) : 86 - 87
  • [7] A treatment planning system for stereotactic radiotherapy
    Benassi, M
    Gentile, FP
    Begnozzi, L
    Chiatti, L
    Malaspina, F
    Carpino, S
    ANTICANCER RESEARCH, 1995, 15 (5B) : 2239 - 2245
  • [8] Automated Radiotherapy Treatment Planning
    Moore, Kevin L.
    SEMINARS IN RADIATION ONCOLOGY, 2019, 29 (03) : 209 - 218
  • [9] Optimal treatment planning of extracranial stereotactic conformal radiotherapy for medically inoperable lung cancer
    Wang, L
    Feigenberg, S
    Paskalev, K
    Chen, L
    Qin, L
    Ma, CC
    Movsas, B
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S630 - S631
  • [10] The role of conformal stereotactic radiotherapy in the treatment of recurrent medulloblastoma
    Tiefenbacher, U
    Debus, J
    Huber, PE
    Fuss, M
    Selle, B
    Wannenmacher, M
    RADIOLOGY, 1998, 209P : 361 - 361