Air-conditioner filters enriching dust mites allergen

被引:1
|
作者
Zhan, Xiaodong [1 ,2 ]
Li, Chaopin [1 ,3 ]
Xu, Haifeng [3 ]
Xu, Pengfei [3 ]
Zhu, Haibin [3 ]
Diao, Jidong [1 ]
Li, Na [1 ]
Zhao, Beibei [1 ]
机构
[1] Wannan Med Univ, Sch Basic Med, Dept Med Parasitol, Wuhu 241002, Anhui, Peoples R China
[2] Anhui Normal Univ, Collede Life Sci, Wuhu 241002, Anhui, Peoples R China
[3] Anhui Univ Sci & Technol, Sch Earth & Environm, Lab Environm & Hlth, Huainan 232001, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Acaridia; Astigmatina; dust mite; major group allergen 1; air-conditioner filters; ASTHMA; IGE; PREVALENCE;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
We detected the concentration of dust mites allergen (Der f1 & Der p1) in the air of different places before and after the starting of air-conditioners in Wuhu City, Anhui, China, and to discuss the relation between the dust mites allergen in air-conditioner filters and the asthma attack. The dust samples were collected from the air-conditioner filters in dining rooms, shopping malls, hotels and households respectively. Concentrations of dust mites major group allergen 1 (Der f 1, Der p1) were detected with enzyme linked immunosorbent assay (ELISA), and the dust mite immune activities were determined by dot-ELISA. The concentration of Der f1 in dining rooms, shopping malls, hotels and households was 1.52 mu g/g, 1.24 mu g/g, 1.31 mu g/g and 1.46 mu g/g respectively, and the concentration of Der p1 in above-mentioned places was 1.23 mu g/g, 1.12 mu g/g, 1.16 mu g/g and 1.18 mu g/g respectively. The concentration of Der f1 & Der p1 in air was higher after the air-conditioners starting one hours later, and the difference was significant (P<0.05, respectively). Additionally, dot-ELISA findings revealed that the allergen extracted from the dust was capable of reacting with IgE from the sera of asthma mice allergic to dust mites. The study concludes that air-conditioner filters can enrich dust mites major group allergen, and the allergens can induce asthma. The air-conditioner filters shall be cleaned or replaced regularly to prevent or reduce accumulation of the dust mites and its allergens.
引用
收藏
页码:4539 / 4544
页数:6
相关论文
共 50 条
  • [41] EXTREMELY THIN MICROCOMPUTER-CONTROLLED AIR-CONDITIONER
    UMEZU, K
    NAKADA, M
    SHIMMA, Y
    TOSHIBA REVIEW, 1979, (122): : 48 - 52
  • [42] A novel system of the isothermal dehumidification in a room air-conditioner
    Han, Xing
    Zhang, Xu
    Wang, Lihui
    Niu, Runping
    ENERGY AND BUILDINGS, 2013, 57 : 14 - 19
  • [43] SOLAR-POWERED AIR-CONDITIONER TECHNOLOGY.
    Tanaka, Hideki
    Usui, Sanpei
    Hitachi Review, 1981, 30 (01): : 25 - 30
  • [44] PERFORMANCE DEGRADATION OF AN AIR-CONDITIONER CAUSED BY CYCLIC OPERATIONS
    BAHEL, V
    BAKHSH, H
    ZUBAIR, S
    ENERGY, 1988, 13 (02) : 191 - 195
  • [45] Flow velocity around air-conditioner outdoor unit
    Xu, Chen
    Ou, Chunshan
    Gu, Xiaojiang
    Wang, Chao
    Mao, Yijun
    PHYSICS OF FLUIDS, 2025, 37 (01)
  • [46] SOLAR OPERATED ABSORPTION AIR-CONDITIONER FOR A KUFRA HOUSE
    UPPAL, AH
    MUNEER, T
    APPLIED ENERGY, 1984, 16 (04) : 259 - 281
  • [47] The Spray Fan and Saving Water of the Textile Air-conditioner
    Xu, Hong
    Hui, Jing
    CHINA FUNCTIONAL MATERIALS TECHNOLOGY AND INDUSTRY FORUM, 2013, 320 : 753 - 756
  • [48] A Novel Window Type Air-conditioner with Energy Recovering
    Luo, Qinghai
    Zhang, Pengfei
    Yang, Xiufei
    Zou, Jun
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 3021 - 3024
  • [49] AIR-CONDITIONER DISEASE - RESULTS OF AN INDUSTRIAL MEDICINE SURVEY
    MOLINA, C
    AIACHE, JM
    BEDU, M
    MENAUT, P
    WAHL, D
    BRESTOWSKI, J
    GRALL, Y
    NOUVELLE PRESSE MEDICALE, 1982, 11 (31): : 2325 - 2329
  • [50] BACTERIOLOGICAL SAFETY OF THE PCM-40 AIR-CONDITIONER
    DUMAS, JL
    DUCEL, G
    ROUGE, JC