Air-conditioner filters enriching dust mites allergen

被引:1
|
作者
Zhan, Xiaodong [1 ,2 ]
Li, Chaopin [1 ,3 ]
Xu, Haifeng [3 ]
Xu, Pengfei [3 ]
Zhu, Haibin [3 ]
Diao, Jidong [1 ]
Li, Na [1 ]
Zhao, Beibei [1 ]
机构
[1] Wannan Med Univ, Sch Basic Med, Dept Med Parasitol, Wuhu 241002, Anhui, Peoples R China
[2] Anhui Normal Univ, Collede Life Sci, Wuhu 241002, Anhui, Peoples R China
[3] Anhui Univ Sci & Technol, Sch Earth & Environm, Lab Environm & Hlth, Huainan 232001, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Acaridia; Astigmatina; dust mite; major group allergen 1; air-conditioner filters; ASTHMA; IGE; PREVALENCE;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
We detected the concentration of dust mites allergen (Der f1 & Der p1) in the air of different places before and after the starting of air-conditioners in Wuhu City, Anhui, China, and to discuss the relation between the dust mites allergen in air-conditioner filters and the asthma attack. The dust samples were collected from the air-conditioner filters in dining rooms, shopping malls, hotels and households respectively. Concentrations of dust mites major group allergen 1 (Der f 1, Der p1) were detected with enzyme linked immunosorbent assay (ELISA), and the dust mite immune activities were determined by dot-ELISA. The concentration of Der f1 in dining rooms, shopping malls, hotels and households was 1.52 mu g/g, 1.24 mu g/g, 1.31 mu g/g and 1.46 mu g/g respectively, and the concentration of Der p1 in above-mentioned places was 1.23 mu g/g, 1.12 mu g/g, 1.16 mu g/g and 1.18 mu g/g respectively. The concentration of Der f1 & Der p1 in air was higher after the air-conditioners starting one hours later, and the difference was significant (P<0.05, respectively). Additionally, dot-ELISA findings revealed that the allergen extracted from the dust was capable of reacting with IgE from the sera of asthma mice allergic to dust mites. The study concludes that air-conditioner filters can enrich dust mites major group allergen, and the allergens can induce asthma. The air-conditioner filters shall be cleaned or replaced regularly to prevent or reduce accumulation of the dust mites and its allergens.
引用
收藏
页码:4539 / 4544
页数:6
相关论文
共 50 条
  • [21] Effect of the Muffler on Fluctuation Noise in the Air-conditioner
    Zhang, Liping
    2015 2ND INTERNATIONAL CONFERENCE ON INTELLIGENT MATERIALS AND MECHATRONICS (IMM 2015), 2015, : 49 - 52
  • [22] MOLD CONTAMINATION OF AUTOMOBILE AIR-CONDITIONER SYSTEMS
    KUMAR, P
    MARIER, R
    LOPEZ, M
    FAN, W
    SIAK, J
    LEECH, S
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1987, 79 (01) : 210 - 210
  • [23] Parametric studies on a desiccant assisted air-conditioner
    Subramanyam, N
    Maiya, MP
    Murthy, SS
    APPLIED THERMAL ENGINEERING, 2004, 24 (17-18) : 2679 - 2688
  • [24] High-efficiency thermoelectric air-conditioner
    Wang, Tie-min
    Zhang, Jian-zhong
    Ma, Hong-kui
    HIGH-PERFORMANCE CERAMICS IV, PTS 1-3, 2007, 336-338 : 888 - +
  • [25] Perfluoroalkyl substances (PFASs) in air-conditioner filter dust of indoor microenvironments in Greece: Implications for exposure
    Besis, Athanasios
    Botsaropoulou, Elisavet
    Samara, Constantini
    Katsoyiannis, Athanasios
    Hanssen, Linda
    Huber, Sandra
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2019, 183
  • [26] Development and investigation of air-cooled thermoelectric air-conditioner
    Zhang, H.J.
    Dong, X.J.
    Tao, W.Q.
    Feng, Q.Y.
    Zou, T.
    Pan Tao Ti Hsueh Pao/Chinese Journal of Semiconductors, 2001, 22 (02): : 220 - 223
  • [27] Design and performance analysis of a metal hydride air-conditioner
    Gopal, MR
    Murthy, SS
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1997, 21 (01) : 55 - 67
  • [28] Towards a Residential Air-Conditioner Usage Model for Australia
    Goldsworthy, Mark
    ENERGIES, 2017, 10 (09):
  • [29] Diagnosis of Air-Conditioner by Using Its Dynamic Property
    Kawai, Tadao
    Kushizaki, Seiya
    ENGINEERING ASSET MANAGEMENT - SYSTEMS, PROFESSIONAL PRACTICES AND CERTIFICATION, 2015, : 43 - 52
  • [30] Remote terminal air-conditioner unit for power management
    Srisuwan, Khomkrit
    Sangmalee, Vansan
    Thunyaphirak, Veera
    Skunpong, Apirak
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 395 - +