Air-conditioner filters enriching dust mites allergen

被引:1
|
作者
Zhan, Xiaodong [1 ,2 ]
Li, Chaopin [1 ,3 ]
Xu, Haifeng [3 ]
Xu, Pengfei [3 ]
Zhu, Haibin [3 ]
Diao, Jidong [1 ]
Li, Na [1 ]
Zhao, Beibei [1 ]
机构
[1] Wannan Med Univ, Sch Basic Med, Dept Med Parasitol, Wuhu 241002, Anhui, Peoples R China
[2] Anhui Normal Univ, Collede Life Sci, Wuhu 241002, Anhui, Peoples R China
[3] Anhui Univ Sci & Technol, Sch Earth & Environm, Lab Environm & Hlth, Huainan 232001, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Acaridia; Astigmatina; dust mite; major group allergen 1; air-conditioner filters; ASTHMA; IGE; PREVALENCE;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
We detected the concentration of dust mites allergen (Der f1 & Der p1) in the air of different places before and after the starting of air-conditioners in Wuhu City, Anhui, China, and to discuss the relation between the dust mites allergen in air-conditioner filters and the asthma attack. The dust samples were collected from the air-conditioner filters in dining rooms, shopping malls, hotels and households respectively. Concentrations of dust mites major group allergen 1 (Der f 1, Der p1) were detected with enzyme linked immunosorbent assay (ELISA), and the dust mite immune activities were determined by dot-ELISA. The concentration of Der f1 in dining rooms, shopping malls, hotels and households was 1.52 mu g/g, 1.24 mu g/g, 1.31 mu g/g and 1.46 mu g/g respectively, and the concentration of Der p1 in above-mentioned places was 1.23 mu g/g, 1.12 mu g/g, 1.16 mu g/g and 1.18 mu g/g respectively. The concentration of Der f1 & Der p1 in air was higher after the air-conditioners starting one hours later, and the difference was significant (P<0.05, respectively). Additionally, dot-ELISA findings revealed that the allergen extracted from the dust was capable of reacting with IgE from the sera of asthma mice allergic to dust mites. The study concludes that air-conditioner filters can enrich dust mites major group allergen, and the allergens can induce asthma. The air-conditioner filters shall be cleaned or replaced regularly to prevent or reduce accumulation of the dust mites and its allergens.
引用
收藏
页码:4539 / 4544
页数:6
相关论文
共 50 条
  • [31] Quantitation of dust mites and allergen in small dust samples
    Arlian, LG
    Morgan, MS
    Goelz, JF
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1999, 104 (03) : 707 - 709
  • [32] Compositional characteristics of black-carbon and nanoparticles in air-conditioner dust from an inhabitable industrial metropolis
    Ali, Muhammad Ubaid
    Liu, Guijian
    Yousaf, Balal
    Abbas, Qumber
    Ullah, Habib
    Munir, Mehr Ahmad Mujtaba
    Zhang, Hong
    JOURNAL OF CLEANER PRODUCTION, 2018, 180 : 34 - 42
  • [33] R-134A AUTO AIR-CONDITIONER UNVEILED
    不详
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1992, 34 (07): : 12 - 12
  • [34] Residential air-conditioner usage in China and efficiency standardization
    Wu, Jianghong
    Liu, Chaopeng
    Li, Hongqi
    Ouyang, Dong
    Cheng, Jianhong
    Wang, Yuanxia
    You, Shaofang
    ENERGY, 2017, 119 : 1036 - 1046
  • [35] PAPER YOUR LIVING-ROOM WITH AN AIR-CONDITIONER
    BEARD, J
    NEW SCIENTIST, 1994, 144 (1947) : 22 - 22
  • [36] Identification of noise sources in scroll compressor for air-conditioner
    Jin-Kab Lee
    KSME International Journal, 2000, 14 : 597 - 604
  • [37] EFFECTIVENESS OF APPLICATION OF LOAD SHEDDERS ON AIR-CONDITIONER DEMAND
    Hradilek, Zdenek
    Osladil, Michal
    PROCEEDINGS OF THE 6TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2005, 2005, : 186 - 190
  • [38] Identification of noise sources in scroll compressor for air-conditioner
    Lee, JK
    KSME INTERNATIONAL JOURNAL, 2000, 14 (06): : 597 - 604
  • [39] EFFECT OF THE OUTDOOR UNIT ARRANGEMENTS ON COP OF AN AIR-CONDITIONER
    Li, Hao
    Huang, Chen
    Zou, Zhijun
    Wang, Fei
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 2273 - 2278
  • [40] Effect of Dents in Condenser Fins on Air-Conditioner Performance
    Sitzmann, Matthew J.
    Lu, Frank K.
    Smith, Steve R.
    ASHRAE TRANSACTIONS 2010, VOL 116, PT 1, 2010, 116 : 336 - +