Comparison of the BAX® System with a multiplex PCR method for simultaneous detection and identification of Campylobacter jejuni and Campylobacter coli in environmental samples

被引:14
|
作者
Manfreda, G [1 ]
De Cesare, A [1 ]
Bondioli, V [1 ]
Franchini, A [1 ]
机构
[1] Univ Bologna, Alma Mater Studiorum, Dept Food Sci, I-40126 Bologna, Italy
关键词
Campylobacter jejuni; Campylobacter coli; multiplex PCR; environment;
D O I
10.1016/S0168-1605(03)00073-4
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The Campylobacter detection is performed by conventional culture methods and the identification of Campylobacter jejuni and Campylobacter coli is principally based on the hippurate hydrolysis test. The two major drawbacks of this biochemical test for species identification include the inconsistency of the results and the presence of atypical strains, which can lead to the misidentification of an isolate. As an alternative, multiplex polymerase chain reaction (mPCR) protocols for the simultaneous detection and identification of different Campylobacter species have been developed. This study examined the performances of an experimental BAX(R) System assay for the C. jejuni and C. coli identification in comparison to a multiplex PCR protocol recently published. The samples tested were represented by 106 environmental swabs collected on Teflon strips and tables, stainless steel saws, hooks and trays, ceramic floors and walls, as well as equipment surfaces, located in a swine (N = 50) and a poultry (N = 56) slaughterhouse. The highest Campylobacter detection rate was obtained after 48 h of enrichment by using both the PCR procedures. After 24 h, the BAX(R) System provides a more rapid and accurate Campylobacter detection and identification assay than the multiplex PCR. Except for two samples, all the broths where Campylobacter cells were detected after 24 or 48 h of enrichment, with at least one of the PCR protocols, gave Campylobacter colonies using the culture method. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [1] Multiplex PCR assays for simultaneous identification of Campylobacter jejuni and Campylobacter coli
    Wieczorek, M
    Osek, J
    [J]. MEDYCYNA WETERYNARYJNA-VETERINARY MEDICINE-SCIENCE AND PRACTICE, 2005, 61 (07): : 797 - 799
  • [2] Biofunctionalized Magnetic Nanoparticles with Multiplex Touchdown PCR for Simultaneous and Rapid Detection/Identification of Campylobacter jejuni and Campylobacter coli
    Wenbap, Pattarapong
    Rattanarojpong, Triwit
    Khunrae, Pongsak
    Luangtongkum, Taradon
    Erickson, Larry E.
    Hansen, Ryan R.
    Tuitemwong, Pravate
    [J]. JOURNAL OF NANOMATERIALS, 2022, 2022
  • [3] Multiplex PCR for identification of Campylobacter coli and Campylobacter jejuni from pure cultures and directly on stool samples
    Persson, S
    Olsen, KEP
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 2005, 54 (11) : 1043 - 1047
  • [4] Identification of Campylobacter jejuni and Campylobacter coli from refrigerated chicken carcasses by Multiplex PCR
    Medeiros, Valeria de Mello
    Lopes Bricio, Silvia Maria
    Clementino, Maysa Mandetta
    [J]. VIGILANCIA SANITARIA EM DEBATE-SOCIEDADE CIENCIA & TECNOLOGIA, 2015, 3 (03): : 97 - 103
  • [5] PCR-ELISAs for the detection of Campylobacter jejuni and Campylobacter coli in poultry samples
    Grennan, B
    O'Sullivan, NA
    Fallon, R
    Carroll, C
    Smith, T
    Glennon, M
    Maher, M
    [J]. BIOTECHNIQUES, 2001, 30 (03) : 602 - +
  • [6] A Comparison between Hippurate Hydrolysis and Multiplex PCR for Differentiating Campylobacter coli and Campylobacter jejuni
    Adzitey, Frederick
    Corry, Janet
    [J]. TROPICAL LIFE SCIENCES RESEARCH, 2011, 22 (01) : 91 - 98
  • [7] Comparison of Established PCR Assays for Accurate Identification of Campylobacter jejuni and Campylobacter coli
    Kabir, S. M. Lutful
    Chowdhury, Nityananda
    Asakura, Masahiro
    Shiramaru, Sachi
    Kikuchi, Ken
    Hinenoya, Atsushi
    Neogi, Sucharit Basu
    Yamasaki, Shinji
    [J]. JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2019, 72 (02) : 81 - 87
  • [8] Detection and quantification of Campylobacter jejuni and Campylobacter coli using real-time multiplex PCR
    Toplak, N.
    Kovac, M.
    Piskernik, S.
    Mozina, S. Smole
    Jersek, B.
    [J]. JOURNAL OF APPLIED MICROBIOLOGY, 2012, 112 (04) : 752 - 764
  • [9] PCR detection, identification to species level, and fingerprinting of Campylobacter jejuni and Campylobacter coli direct from diarrheic samples
    Linton, D
    Lawson, AJ
    Owen, RJ
    Stanley, J
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (10) : 2568 - 2572
  • [10] Development of a multiplex PCR assay for identification of Campylobacter coli, Campylobacter fetus, Campylobacter hyointestinalis subsp hyointestinalis, Campylobacter jejuni, Campylobacter lari and Campylobacter upsaliensis
    Yamazaki-Matsune, Wataru
    Taguchi, Masurni
    Seto, Kazuko
    Kawahara, Ryuji
    Kawatsu, Kentaro
    Kumeda, Yuko
    Kitazato, Miyoshi
    Nukina, Masafumi
    Misawa, Naoaki
    Tsukamoto, Teizo
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 2007, 56 (11) : 1467 - 1473