Hot sanitary water production with CO2 heat pumps: Effect of control strategy on system performance and stratification inside the storage tank

被引:10
|
作者
Tammaro, M. [1 ]
Mauro, A. W. [1 ]
Montagud, C. [2 ]
Corberan, J. M. [2 ]
Mastrullo, R. [1 ]
机构
[1] Univ Naples Federico II, Dipartimento Ingn Ind, P Le Tecchio 80, Naples, Italy
[2] Univ Politecn Valencia, Inst Ingn Energet, Camino Vera S-N, E-46022 Valencia, Spain
关键词
Storage tank control; Sanitary hot water; Heat pump; Parametric analysis; Cost; REJECTION PRESSURE; CARBON-DIOXIDE; REFRIGERANT;
D O I
10.1016/j.applthermaleng.2016.01.094
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work three different control strategies for the production of sanitary hot water by means of an electric heat pump working with CO2 are investigated. The heat pump is a prototype, here modelled in the vapour-compression software package IMST-ART. By simulating this model, the performance of the heat pump is correlated to the boundary conditions and is scaled to different sizes, namely 1, 1.5, and 2 times larger than the reference system. After having chosen an application for which the load profile of sanitary hot water during the year is known, these heat pumps are simulated in a TRNSYS16 model where the production of sanitary hot water and the consumption are buffered by the presence of a tank. Key parameter in guaranteeing comfort and good performance of the system is the stratification inside the storage tank. The size of the tank necessary to keep a certain level of comfort at the user is then determined through a parametric analysis for each size of the heat pump. The energetic performance is also evaluated for each system in terms of seasonal performance factor. Then, the results obtained are compared with a different system where the heat pump is equipped with an inverter and the circulation pump follows a different control logic. The size of the tank and the seasonal performance factor are therefore determined in this case too. Moreover, a "night&day" control logic is compared to these first two options to have a baseline of comparison in terms of volume of storage needed to guarantee a same level of comfort and performance. To provide information also on the running costs, a parametric analysis was run varying the type of control, the heat pump and the tank sizes for different load profiles. The results show that the size of the heat pump has a significant effect on the comfort of the user, which usually leads to oversizing of the storage tank when the load profile is unknown. With regard to this, the results obtained for the alternative control system show a 20% reduction of the volume of the tank, given a certain level of comfort, and is therefore useful to reduce the size of the storage tank. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:730 / 740
页数:11
相关论文
共 50 条
  • [41] A novel frost-free control strategy and its energy evaluation of the CO2 heat pump system
    Wang, Anci
    Yin, Xiang
    Fang, Jianmin
    Jia, Fan
    Song, Yulong
    Cao, Feng
    APPLIED THERMAL ENGINEERING, 2022, 201
  • [42] Experimental study on CO2 secondary throttling heat pump system with dynamic control strategy in electric vehicle
    Teng, Haixu
    Li, Ming
    Liu, Zhikun
    Wang, Jun
    Xiong, Shuangyuan
    Lu, Chunhong
    Song, Zhanzhuo
    Jiang, Yan
    Chang, Wei
    APPLIED THERMAL ENGINEERING, 2025, 268
  • [43] Performance analysis and operation optimization of air-to-water CO2 heat pump with phase change thermal storage
    Wang, Zhihua
    Li, Guichen
    Wang, Fenghao
    Liu, Zixuan
    Wang, Ming
    ENERGY AND BUILDINGS, 2020, 209
  • [44] Influence of Pressure Control Strategy on Long-term Energy Efficiency of CO2 Heat Pump Water Heater
    Zhao, Xiaoxuan
    He, Yujia
    Cheng, Jiahao
    Zhang, Chunlu
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2024, 45 (02): : 324 - 327
  • [45] Energetic and economic analysis of decoupled strategy for heating and cooling production with CO2 booster heat pumps for ultra-low temperature district network
    Quirosa, Gonzalo
    Torres, Miguel
    Soltero, Victor Manuel
    Chacartegui, Ricardo
    JOURNAL OF BUILDING ENGINEERING, 2022, 45
  • [46] Heating Control Strategy of CO2 Heat Pump Air Conditioning System of Electric Vehicle Based on Waste Heat Recovery Technology
    Zhang, Yan
    Zhao, Yu
    Wu, Limin
    He, Liange
    ENERGY TECHNOLOGY, 2024,
  • [47] Experimental study on the effect of compressor frequency on the performance of transcritical CO2 heat pump system with regenerator
    Yang, Ling-Xiao
    Wei, Xin-Li
    Zhao, Ling-Hua
    Qin, Xiang
    Zhang, Dong-Wei
    APPLIED THERMAL ENGINEERING, 2019, 150 : 1216 - 1223
  • [48] Numerical Analysis for Performance Evaluation of a Multi-Functional CO2 Heat Pump Water Heating System
    Yokoyama, Ryohei
    Ohkura, Masashi
    Nakamata, Takuya
    Wakui, Tetsuya
    APPLIED SCIENCES-BASEL, 2018, 8 (10):
  • [49] Experimental investigation on the performance of transcritical CO2 ejector-expansion heat pump water heater system
    Zhu, Yinhai
    Huang, Yulei
    Li, Conghui
    Zhang, Fuzhen
    Jiang, Pei-Xue
    ENERGY CONVERSION AND MANAGEMENT, 2018, 167 : 147 - 155
  • [50] Performance analysis of a CO2 heat pump water heating system under a daily change in a standardized demand
    Yokoyama, Ryohei
    Wakui, Tetsuya
    Kamakari, Junya
    Takemura, Kazuhisa