Numerical Analysis for Performance Evaluation of a Multi-Functional CO2 Heat Pump Water Heating System

被引:2
|
作者
Yokoyama, Ryohei [1 ]
Ohkura, Masashi [1 ]
Nakamata, Takuya [1 ]
Wakui, Tetsuya [1 ]
机构
[1] Osaka Prefecture Univ, Dept Mech Engn, Naka Ku, 1-1 Gakuen Cho, Sakai, Osaka 5998531, Japan
来源
APPLIED SCIENCES-BASEL | 2018年 / 8卷 / 10期
关键词
water heating; heat pump; thermal storage; natural refrigerant; system performance; dynamic simulation; CARBON-DIOXIDE; REJECTION PRESSURE; OPTIMIZATION; SIMULATION; CYCLE;
D O I
10.3390/app8101829
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In recent years, CO2 heat pump water heating systems have been developed, and their performances have been enhanced while their functions have been expanded. In a multi-functional system, used for both hot water supply and bath heating, hot water retrieved from the top of a storage tank is returned to its bottom or side after heat exchange for bath heating, which destroys the stratified temperature distribution in the storage tank and degrades the system performance. In this paper, the performance of a multi-functional CO2 heat pump water heating system has been evaluated by numerical simulation. A system model was created by combining component models for a CO2 heat pump, mixing valves, a storage tank, a heat exchanger, and a bathtub. Partly, perfect mixing by hot water return was assumed in the component model for the storage tank, and its validity was verified through experiments. A performance analysis has been conducted under daily repeated hot water and bath heating demands, and the system performance was evaluated at a periodically steady state. As a result, the system efficiency and the volume of unused hot water in the multi-functional system decreased by 4.9% and 16.3%, respectively, as compared to those in the uni-functional system, when hot water returned to the bottom of the storage tank. When the position for hot water return is heightened, the system efficiency becomes higher than that in the uni-functional system, while the volume of unused hot water decreases furthermore.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Performance analysis of a multi-functional Heat pump system in heating mode
    Liu, Xiaoyu
    Ni, Long
    Lau, Siu-Kit
    Li, Haorong
    [J]. APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) : 698 - 710
  • [2] Numerical analysis on performance enhancement of a CO2 heat pump water heating system by extracting tepid water
    Ohkura, Masashi
    Yokoyama, Ryohei
    Nakamata, Takuya
    Wakui, Tetsuya
    [J]. ENERGY, 2015, 87 : 435 - 447
  • [3] Performance analysis of a CO2 heat pump water heating system by numerical simulation with a simplified model
    Yokoyama, Ryohei
    Okagaki, Shinsuke
    Ito, Koichi
    Takemura, Kazuhisa
    [J]. ECOS 2006: PROCEEDINGS OF THE 19TH INTERNATIONAL CONFERENCE ON EFFICIENCY, COST, OPTIMIZATION, SIMULATION AND ENVIRONMENTAL IMPACT OF ENERGY SYSTEMS, VOLS 1-3, 2006, : 1353 - +
  • [4] The Heating Performance of a CO2 Heat Pump Water Heater
    Baek, Changhyun
    Lee, Eungchan
    Kang, Hoon
    Kim, Yongchan
    Cho, Honghyun
    Cho, Sungwook
    [J]. ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 258 - 263
  • [5] Performance analysis of a multi-functional heat pump system in cooling mode
    Liu, Xiaoyu
    Ni, Long
    Lau, Siu-Kit
    Li, Haorong
    [J]. APPLIED THERMAL ENGINEERING, 2013, 59 (1-2) : 253 - 266
  • [6] Influence of ambient temperatures on performance of a CO2 heat pump water heating system
    Yokoyama, R
    Shimizu, T
    Ito, K
    Takemura, K
    [J]. PROCEEDINGS OF ECOS 2005, VOLS 1-3: SHAPING OUR FUTURE ENERGY SYSTEMS, 2005, : 1097 - 1104
  • [7] Performance Estimation and Optimal Operation of a CO2 Heat Pump Water Heating System
    Yokoyama, R.
    Kato, R.
    Wakui, T.
    Takemura, K.
    [J]. INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2013, 16 (02) : 62 - 72
  • [8] Influence of ambient temperatures on performance of a CO2 heat pump water heating system
    Yokoyama, Ryohei
    Shimizu, Takeshi
    Ito, Koichi
    Takemura, Kazuhisa
    [J]. ENERGY, 2007, 32 (04) : 388 - 398
  • [9] Optimization and analysis of a multi-functional heat pump system with air source and gray water source in heating mode
    Liu, Xiaoyu
    Lau, Siu-Kit
    Li, Haorong
    [J]. ENERGY AND BUILDINGS, 2014, 69 : 1 - 13
  • [10] Experimental and numerical investigation on the heating performance of a novel multi-functional heat pump system with solar-air composite heat source
    Cai, Jingyong
    Zhou, Haihua
    Xu, Lijie
    Zhang, Tao
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2021, 73