Qualitative and quantitative evaluation of a new wearable device for ECG and respiratory Holter monitoring

被引:23
|
作者
Sarmento, Antonio [1 ]
Vignati, Carlo [2 ,3 ]
Paolillo, Stefania [4 ]
Lombardi, Carolina [5 ]
Scoccia, Alessandra [2 ]
Nicoli, Flavia [2 ]
Mapelli, Massimo [2 ]
Leonardi, Alessandra [6 ]
Ossola, Dario [6 ]
Rigoni, Rudy [1 ,6 ]
Agostoni, Piergiuseppe [2 ,3 ]
Aliverti, Andrea [1 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, Milan, Italy
[2] IRCCS, Ctr Cardiol Monzino, Milan, Italy
[3] Univ Milan, Dept Clin Sci & Community Hlth, Cardiovasc Sect, Milan, Italy
[4] IRCCS SDN, Naples, Italy
[5] S Luca Hosp, Sleep Med Ctr, IRCCS, Ist Auxol Italiano, Milan, Italy
[6] LIFE Corp SA, Luxembourg, Luxembourg
关键词
ECG monitoring; Respiratory monitoring; wearable device; Apnea; OBSTRUCTIVE SLEEP; HEART-FAILURE; APNEA;
D O I
10.1016/j.ijcard.2018.06.044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Recent advances in wearable technology make continuous cardiorespiratory monitoring possible, with potential applications in assessment of cardiopulmonary patients, healthy subjects and athletes. The aim of the present study was to qualitatively and quantitatively evaluate a new wearable device (Learn Inspire Free Entertain = L.I.F.E.) by embedding in a compression shirt a 12-lead ECG system and 5 respiratory sensors. Methods: Thirty cardiorespiratory patients and ten healthy subjects were studied for 24 h during their usual life activities. In 8 healthy subjects, simultaneous measurements of the device and of an ergo-spirometer were performed during different levels of ventilation in five different body positions. The quality of ECG signals in terms of measurability of heart rate, P wave, QRS complex and ST segment, was analyzed by four expert cardiologists/ respiratory physiologists using an arbitrary 1-5 scale. The sum of the respiratory signals was used to calculate the respiratory rate, inspiratory time and relative changes of tidal volume. These parameters were compared to ergo-spirometer measurements. Results: Median quality value was >3 for heart rate, QRS complex, ST segment and P wave (except in L3, aVL, aVF, V1 and V2 leads). Median quality of respiratory traces was >4 in patients and between 3 and 4 in healthy subjects. The respiratory monitoring of respiratory rate and inspiratory time was accurate in all body positions. Tidal volumes were underestimated due to a high level of ventilation. Conclusions: The L.I.F.E. device provides an accurate continuous monitoring of cardiorespiratory signals during the 24 h both in normal subjects and cardiorespiratory patients. (C) 2018 Elsevier B.V. All right reserved.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [41] Qualitative and quantitative evaluation of equine respiratory mechanics by impulse oscillometry
    van Erck, E
    Votion, D
    Art, T
    Lekeux, P
    EQUINE VETERINARY JOURNAL, 2006, 38 (01) : 52 - 58
  • [42] Standalone Wearable Lung Performance and Air Quality Monitoring Device for Chronic Respiratory Diseases
    Patel, Sahaj Anilbhai
    Saha, Reepa
    Mirbozorgi, S. Abdollah
    Samain, Sabrin
    Aishwarya, Kaushal
    Nazari, Rouzbeh
    Karimi, Maryam
    2022 20TH IEEE INTERREGIONAL NEWCAS CONFERENCE (NEWCAS), 2022, : 139 - 142
  • [43] Anytime ECG Monitoring through the Use of a Low-Cost, User-Friendly, Wearable Device
    Randazzo, Vincenzo
    Ferretti, Jacopo
    Pasero, Eros
    SENSORS, 2021, 21 (18)
  • [44] A Wearable Device for Real-Time ECG Monitoring and Cardiovascular Arrhythmia Detection for Resource Constrained Regions
    Mishra, Biswajit
    Arora, Neha
    Vora, Yash
    PROCEEDINGS OF THE 2018 8TH INTERNATIONAL SYMPOSIUM ON EMBEDDED COMPUTING AND SYSTEM DESIGN (ISED 2018), 2018, : 48 - 52
  • [45] Wearable Mobile Ear-based ECG Monitoring Device Using Graphene-Coated Sensors
    Celik, Numan
    Balachandran, Wamadeva
    Manivannan, Nadarajah
    Winter, Eva-Maria
    Schnalzer, Bianca
    Burgsteiner, Harald
    2017 IEEE SENSORS, 2017, : 133 - 135
  • [46] Exploring the potential of a new wearable sleep monitoring device for clinical application
    Li, Xin
    Li, Min
    Tian, Mei
    Liu, Qi
    Zhou, Xiaomeng
    Liu, Hu
    Li, Rui
    Li, Zhenzhong
    Dong, Hui
    Jia, Lijing
    Liu, Yaling
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2025, 99
  • [47] Quantitative Evaluation of TUG test with IMU and sEMG sensors in Wearable Device (poster)
    Kim, Min-Kyu
    Park, Dong-Jun
    Lee, Jun-Woo
    Ahn, Se-Jin
    Shin, Myung-Jun
    2019 22ND IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE AND ENGINEERING (IEEE CSE 2019) AND 17TH IEEE INTERNATIONAL CONFERENCE ON EMBEDDED AND UBIQUITOUS COMPUTING (IEEE EUC 2019), 2019, : 495 - 495
  • [48] A new method for manufacturing dry electrodes on textiles. Validation for wearable ECG monitoring
    Ferri, Josue
    Llinares, Raul
    Segarra, Izan
    Cebrian, Antonio
    Garcia-Breijo, Eduardo
    Millet, Jose
    ELECTROCHEMISTRY COMMUNICATIONS, 2022, 136
  • [49] Validation of Adhesive Single-Lead ECG Device Compared with Holter Monitoring among Non-Atrial Fibrillation Patients
    Kwon, Soonil
    Lee, So-Ryoung
    Choi, Eue-Keun
    Ahn, Hyo-Jeong
    Song, Hee-Seok
    Lee, Young-Shin
    Oh, Seil
    SENSORS, 2021, 21 (09)
  • [50] Quantitative and Comprehensive Evaluation of Qualitative Indices in Dam Safety Monitoring
    Xu, Bo
    Xia, Hui
    Yao, Yuan
    ADVANCED MEASUREMENT AND TEST, PTS 1-3, 2011, 301-303 : 924 - 931