Qualitative and quantitative evaluation of a new wearable device for ECG and respiratory Holter monitoring

被引:23
|
作者
Sarmento, Antonio [1 ]
Vignati, Carlo [2 ,3 ]
Paolillo, Stefania [4 ]
Lombardi, Carolina [5 ]
Scoccia, Alessandra [2 ]
Nicoli, Flavia [2 ]
Mapelli, Massimo [2 ]
Leonardi, Alessandra [6 ]
Ossola, Dario [6 ]
Rigoni, Rudy [1 ,6 ]
Agostoni, Piergiuseppe [2 ,3 ]
Aliverti, Andrea [1 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, Milan, Italy
[2] IRCCS, Ctr Cardiol Monzino, Milan, Italy
[3] Univ Milan, Dept Clin Sci & Community Hlth, Cardiovasc Sect, Milan, Italy
[4] IRCCS SDN, Naples, Italy
[5] S Luca Hosp, Sleep Med Ctr, IRCCS, Ist Auxol Italiano, Milan, Italy
[6] LIFE Corp SA, Luxembourg, Luxembourg
关键词
ECG monitoring; Respiratory monitoring; wearable device; Apnea; OBSTRUCTIVE SLEEP; HEART-FAILURE; APNEA;
D O I
10.1016/j.ijcard.2018.06.044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Recent advances in wearable technology make continuous cardiorespiratory monitoring possible, with potential applications in assessment of cardiopulmonary patients, healthy subjects and athletes. The aim of the present study was to qualitatively and quantitatively evaluate a new wearable device (Learn Inspire Free Entertain = L.I.F.E.) by embedding in a compression shirt a 12-lead ECG system and 5 respiratory sensors. Methods: Thirty cardiorespiratory patients and ten healthy subjects were studied for 24 h during their usual life activities. In 8 healthy subjects, simultaneous measurements of the device and of an ergo-spirometer were performed during different levels of ventilation in five different body positions. The quality of ECG signals in terms of measurability of heart rate, P wave, QRS complex and ST segment, was analyzed by four expert cardiologists/ respiratory physiologists using an arbitrary 1-5 scale. The sum of the respiratory signals was used to calculate the respiratory rate, inspiratory time and relative changes of tidal volume. These parameters were compared to ergo-spirometer measurements. Results: Median quality value was >3 for heart rate, QRS complex, ST segment and P wave (except in L3, aVL, aVF, V1 and V2 leads). Median quality of respiratory traces was >4 in patients and between 3 and 4 in healthy subjects. The respiratory monitoring of respiratory rate and inspiratory time was accurate in all body positions. Tidal volumes were underestimated due to a high level of ventilation. Conclusions: The L.I.F.E. device provides an accurate continuous monitoring of cardiorespiratory signals during the 24 h both in normal subjects and cardiorespiratory patients. (C) 2018 Elsevier B.V. All right reserved.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [31] Development of a Flexible Wireless ECG Monitoring Device With Dry Fabric Electrodes for Wearable Applications
    Masihi, Simin
    Panahi, Masoud
    Maddipatla, Dinesh
    Hanson, Anthony J.
    Fenech, Stephen
    Bonek, Lucas
    Sapoznik, Nicholas
    Fleming, Paul D.
    Bazuin, Bradley J.
    Atashbar, Massood Z.
    IEEE SENSORS JOURNAL, 2022, 22 (12) : 11223 - 11232
  • [32] Comparing a Mobile ECG Device With Holter Monitoring for Patients With Palpitations in an Urgent Care Setting: A Preliminary Study.
    Goel, Hersh, V
    Alpert, Joseph S.
    Shaheen, Mazen H.
    Jones, Trevor A.
    Skinner, David P.
    CIRCULATION, 2018, 138
  • [33] THE ROLE OF HOLTER ECG MONITORING IN THE DIAGNOSIS OF LATENT RHYTHM DISORDERS IN PATIENTS WITH ACUTE RESPIRATORY VIRAL-INFECTIONS
    MOLKOVA, TN
    BOGOMOLOV, BP
    DEVYATKIN, AV
    SEROVA, MV
    TERAPEVTICHESKII ARKHIV, 1991, 63 (09) : 30 - 32
  • [34] Wearable device for monitoring respiratory phases based on breathing sound and chest movement
    Yuasa Y.
    Suzuki K.
    Advanced Biomedical Engineering, 2019, 8 : 85 - 91
  • [35] Wearable Device for Monitoring Respiratory Phases Based on Breathing Sound and Chest Movement
    Yuasa, Yusuke
    Suzuki, Kenji
    ADVANCED BIOMEDICAL ENGINEERING, 2019, 8 : 85 - 91
  • [36] EMD-Based Electrocardiogram Delineation for a Wearable Low-Power ECG Monitoring Device
    Tan, Xiao
    Chen, Xianxiang
    Hu, Xinyu
    Ren, Ren
    Zhou, Bing
    Fang, Zhen
    Xia, Shanhong
    CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2014, 37 (04): : 212 - 221
  • [37] APNEA RECOGNITION IN WEARABLE DEVICE USING THE INTENSIVE EVALUATION OF THE ECG POWER SPECTRAL DENSITY
    Lin, Y.
    Wang, P.
    Lin, C.
    Sadrawi, M.
    Lin, C.
    Hsieh, Y.
    Kuo, C.
    Chien, J.
    Haraikawa, K.
    Abbod, M. F.
    Shieh, J.
    SLEEP, 2018, 41 : A127 - A127
  • [38] A New Wearable ECG Monitor Evaluation and Experimental Analysis: Proof of Concept
    Abualsaud, Khalid
    Chowdhury, Muhammad E. H.
    Gehani, Abdurrazzak
    Yaacoub, Elias
    Khattab, Tamer
    Hammad, Jamal
    2020 16TH INTERNATIONAL WIRELESS COMMUNICATIONS & MOBILE COMPUTING CONFERENCE, IWCMC, 2020, : 1885 - 1890
  • [39] NONINVASIVE MONITORING OF RESPIRATORY VOLUME - EXPERIMENTAL EVALUATION OF A BREATH MONITORING DEVICE
    AMIN, HM
    CIGADA, M
    FORDYCE, WE
    CAMPORESI, EM
    ANAESTHESIA, 1993, 48 (07) : 608 - 610
  • [40] Cardiac Ambulatory Monitoring: New Wireless Device Validated Against Conventional Holter Monitoring in a Case Series
    Murali, Srinivasan
    Brugger, Nicolas
    Rincon, Francisco
    Mashru, Manoj
    Cook, Stephane
    Goy, Jean-Jacques
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2020, 7