Qualitative and quantitative evaluation of a new wearable device for ECG and respiratory Holter monitoring

被引:23
|
作者
Sarmento, Antonio [1 ]
Vignati, Carlo [2 ,3 ]
Paolillo, Stefania [4 ]
Lombardi, Carolina [5 ]
Scoccia, Alessandra [2 ]
Nicoli, Flavia [2 ]
Mapelli, Massimo [2 ]
Leonardi, Alessandra [6 ]
Ossola, Dario [6 ]
Rigoni, Rudy [1 ,6 ]
Agostoni, Piergiuseppe [2 ,3 ]
Aliverti, Andrea [1 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, Milan, Italy
[2] IRCCS, Ctr Cardiol Monzino, Milan, Italy
[3] Univ Milan, Dept Clin Sci & Community Hlth, Cardiovasc Sect, Milan, Italy
[4] IRCCS SDN, Naples, Italy
[5] S Luca Hosp, Sleep Med Ctr, IRCCS, Ist Auxol Italiano, Milan, Italy
[6] LIFE Corp SA, Luxembourg, Luxembourg
关键词
ECG monitoring; Respiratory monitoring; wearable device; Apnea; OBSTRUCTIVE SLEEP; HEART-FAILURE; APNEA;
D O I
10.1016/j.ijcard.2018.06.044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Recent advances in wearable technology make continuous cardiorespiratory monitoring possible, with potential applications in assessment of cardiopulmonary patients, healthy subjects and athletes. The aim of the present study was to qualitatively and quantitatively evaluate a new wearable device (Learn Inspire Free Entertain = L.I.F.E.) by embedding in a compression shirt a 12-lead ECG system and 5 respiratory sensors. Methods: Thirty cardiorespiratory patients and ten healthy subjects were studied for 24 h during their usual life activities. In 8 healthy subjects, simultaneous measurements of the device and of an ergo-spirometer were performed during different levels of ventilation in five different body positions. The quality of ECG signals in terms of measurability of heart rate, P wave, QRS complex and ST segment, was analyzed by four expert cardiologists/ respiratory physiologists using an arbitrary 1-5 scale. The sum of the respiratory signals was used to calculate the respiratory rate, inspiratory time and relative changes of tidal volume. These parameters were compared to ergo-spirometer measurements. Results: Median quality value was >3 for heart rate, QRS complex, ST segment and P wave (except in L3, aVL, aVF, V1 and V2 leads). Median quality of respiratory traces was >4 in patients and between 3 and 4 in healthy subjects. The respiratory monitoring of respiratory rate and inspiratory time was accurate in all body positions. Tidal volumes were underestimated due to a high level of ventilation. Conclusions: The L.I.F.E. device provides an accurate continuous monitoring of cardiorespiratory signals during the 24 h both in normal subjects and cardiorespiratory patients. (C) 2018 Elsevier B.V. All right reserved.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [21] Validation of a Wearable Device and an Algorithm for Respiratory Monitoring During Exercise
    Massaroni, Carlo
    Nicolo, Andrea
    Girardi, Michele
    La Camera, Angelica
    Schena, Emiliano
    Sacchetti, Massimo
    Silvestri, Sergio
    Taffoni, Fabrizio
    IEEE SENSORS JOURNAL, 2019, 19 (12) : 4652 - 4659
  • [22] Monitoring respiratory impedance by wearable sensor device: Protocol and methodology
    Ionescu, Clara M.
    Copot, D.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 36 : 57 - 62
  • [23] Clinical Validation of a Wearable Respiratory Rate Device for Neonatal Monitoring
    Raj, Antony A.
    Preejith, S. P.
    Raja, Vijai Shankar
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 1628 - 1631
  • [24] Comparison of adhesive single-lead ECG device and Holter test for atrial fibrillation monitoring
    Kwon, S.
    Lee, S. R.
    Choi, E. K.
    Ahn, H. J.
    Song, H. S.
    Lee, Y. S.
    EUROPEAN HEART JOURNAL, 2022, 43 : 414 - 414
  • [25] Heart Arrhythmia Detection & Monitoring Using Machine Learning & ECG Wearable Device
    Afadar, Yaman
    Akram, Amna
    Alkeebali, Asmaa
    Majzoub, Sohaib
    2020 SEVENTH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY TRENDS (ITT 2020), 2020, : 107 - 112
  • [26] Evaluation of an implantable ECG monitoring device in vitro and in vivo
    Riistama, Jarno
    Vaeisaenen, Juho
    Heinisuo, Sarni
    Lekkala, Jukka
    Kaihilahti, Jutta
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 5704 - +
  • [27] Economic evaluation of prolonged and enhanced ECG Holter monitoring in acute ischemic stroke patients
    Diekmann, Sandra
    Hoerster, Laura
    Evers, Silvia
    Hiligsmann, Mickael
    Gelbrich, Goetz
    Groeschel, Klaus
    Wachter, Rolf
    Hamann, Gerhard F.
    Kermer, Pawel
    Liman, Jan
    Weber-Krueger, Mark
    Wasem, Juergen
    Neumann, Anja
    CURRENT MEDICAL RESEARCH AND OPINION, 2019, 35 (11) : 1859 - 1866
  • [28] Design of a wearable device for respiratory rate monitoring and detection of anomalous values
    Aya, Juan Manuel
    Narducci, Margarita S.
    IEEE LATIN AMERICA TRANSACTIONS, 2023, 21 (03) : 513 - 518
  • [29] A Wearable Respiratory Monitoring Device - the Between-Days Variability of Calibration
    Heyde, C.
    Mahler, H.
    Roecker, K.
    Gollhofer, A.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2015, 36 (01) : 29 - 34
  • [30] INTRA-ESOPHAGEAL AMBULATORY ECG-RECORDING - A NEW TECHNIQUE IN HOLTER MONITORING
    DARMANATA, J
    MANGERCATS, V
    HEYEN, H
    LIE, KI
    DURRER, D
    CIRCULATION, 1980, 62 (04) : 288 - 288