Qualitative and quantitative evaluation of a new wearable device for ECG and respiratory Holter monitoring

被引:23
|
作者
Sarmento, Antonio [1 ]
Vignati, Carlo [2 ,3 ]
Paolillo, Stefania [4 ]
Lombardi, Carolina [5 ]
Scoccia, Alessandra [2 ]
Nicoli, Flavia [2 ]
Mapelli, Massimo [2 ]
Leonardi, Alessandra [6 ]
Ossola, Dario [6 ]
Rigoni, Rudy [1 ,6 ]
Agostoni, Piergiuseppe [2 ,3 ]
Aliverti, Andrea [1 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, Milan, Italy
[2] IRCCS, Ctr Cardiol Monzino, Milan, Italy
[3] Univ Milan, Dept Clin Sci & Community Hlth, Cardiovasc Sect, Milan, Italy
[4] IRCCS SDN, Naples, Italy
[5] S Luca Hosp, Sleep Med Ctr, IRCCS, Ist Auxol Italiano, Milan, Italy
[6] LIFE Corp SA, Luxembourg, Luxembourg
关键词
ECG monitoring; Respiratory monitoring; wearable device; Apnea; OBSTRUCTIVE SLEEP; HEART-FAILURE; APNEA;
D O I
10.1016/j.ijcard.2018.06.044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Recent advances in wearable technology make continuous cardiorespiratory monitoring possible, with potential applications in assessment of cardiopulmonary patients, healthy subjects and athletes. The aim of the present study was to qualitatively and quantitatively evaluate a new wearable device (Learn Inspire Free Entertain = L.I.F.E.) by embedding in a compression shirt a 12-lead ECG system and 5 respiratory sensors. Methods: Thirty cardiorespiratory patients and ten healthy subjects were studied for 24 h during their usual life activities. In 8 healthy subjects, simultaneous measurements of the device and of an ergo-spirometer were performed during different levels of ventilation in five different body positions. The quality of ECG signals in terms of measurability of heart rate, P wave, QRS complex and ST segment, was analyzed by four expert cardiologists/ respiratory physiologists using an arbitrary 1-5 scale. The sum of the respiratory signals was used to calculate the respiratory rate, inspiratory time and relative changes of tidal volume. These parameters were compared to ergo-spirometer measurements. Results: Median quality value was >3 for heart rate, QRS complex, ST segment and P wave (except in L3, aVL, aVF, V1 and V2 leads). Median quality of respiratory traces was >4 in patients and between 3 and 4 in healthy subjects. The respiratory monitoring of respiratory rate and inspiratory time was accurate in all body positions. Tidal volumes were underestimated due to a high level of ventilation. Conclusions: The L.I.F.E. device provides an accurate continuous monitoring of cardiorespiratory signals during the 24 h both in normal subjects and cardiorespiratory patients. (C) 2018 Elsevier B.V. All right reserved.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [1] A NEW DEVICE FOR DETECTING ST SHIFTS ASSOCIATED WITH POSTURAL CHANGES IN HOLTER ECG MONITORING
    TANABE, T
    KINOSHITA, E
    TAGAWA, R
    HOSHIAI, M
    FURUYA, H
    IDE, M
    KANEMOTO, N
    TOMODA, H
    GOTO, Y
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1983, 47 (08): : 1010 - 1011
  • [2] Wearable ECG Device and Machine Learning for Heart Monitoring
    Alimbayeva, Zhadyra
    Alimbayev, Chingiz
    Ozhikenov, Kassymbek
    Bayanbay, Nurlan
    Ozhikenova, Aiman
    SENSORS, 2024, 24 (13)
  • [3] A portable ECG monitoring device with Bluetooth and Holter capabilities for telemedicine applications
    Lucani, Daniel
    Cataldo, Giancarlos
    Cruz, Julio
    Villegas, Guillermo
    Wong, Sara
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2926 - +
  • [4] Holter ECG monitoring for the evaluation of stroke in the internal medicine department
    Caspi, Inbar
    Freund, Ophir
    Biran, Roni
    Bornstein, Gil
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2022, 31 (12):
  • [5] Issues in wearable computing for medical monitoring applications: A case study of a wearable ECG monitoring device
    Martin, T
    Jovanov, E
    Raskovic, D
    FOURTH INTERNATIONAL SYMPOSIUM ON WEARABLE COMPUTERS, DIGEST OF PAPERS, 2000, : 43 - 49
  • [6] Issues in wearable computing for medical monitoring applications: a case study of a wearable ECG monitoring device
    Martin, Thomas
    Jovanov, Emil
    Raskovic, Dejan
    International Symposium on Wearable Computers, Digest of Papers, 2000, : 43 - 49
  • [7] Evaluation of a new wearable device for indoor and outdoor environmental monitoring
    Bernasconi, Sara
    Angelucci, Alessandra
    Aliverti, Andrea
    2024 IEEE INTERNATIONAL WORKSHOP ON SPORT, TECHNOLOGY AND RESEARCH, STAR 2024, 2024, : 252 - 257
  • [8] A Wearable ECG Monitoring Device with Flexible Embedded Denoising and Compression
    Wang, Chenyu
    Jin, Han
    Qin, Yajie
    Zheng, Li-rong
    ESSCIRC CONFERENCE 2016, 2016, : 87 - 90
  • [9] A Wearable Device for Online and Long-Term ECG Monitoring
    Longoni, Marco
    Carrera, Diego
    Rossi, Beatrice
    Fragneto, Pasqualina
    Pessione, Marco
    Boracchi, Giacomo
    PROCEEDINGS OF THE TWENTY-SEVENTH INTERNATIONAL JOINT CONFERENCE ON ARTIFICIAL INTELLIGENCE, 2018, : 5838 - 5840
  • [10] A Wearable ECG Monitoring Device with Flexible Embedded Denoising and Compression
    Wang, Chenyu
    Jin, Han
    Qin, Yajie
    Zheng, Li-rong
    2016 46TH EUROPEAN SOLID-STATE DEVICE RESEARCH CONFERENCE (ESSDERC), 2016, : 79 - 82