The first trial of phase contrast imaging for digital full-field mammography using a practical molybdenum X-ray tube

被引:79
|
作者
Tanaka, T
Honda, C
Matsuo, S
Noma, K
Oohara, H
Nitta, N
Ota, S
Tsuchiya, K
Sakashita, Y
Yamada, A
Yamasaki, M
Furukawa, A
Takahashi, M
Murata, K
机构
[1] Shiga Univ Med Sci, Dept Radiol, Otsu, Shiga 5202192, Japan
[2] Konica Minolta Med & Graphic Inc, Ctr Res & Dev, Tokyo, Japan
关键词
phase contrast; digital mammography; computed radiography; photothermographic printer; 25-micron pixel size;
D O I
10.1097/01.rli.0000165575.43381.48
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The image quality of a newly developed full-field digital phase contrast mammography (PCM) system and of a conventional screen-film (SF) mammography system were compared via images of a phantom and receiver operating characteristic (ROC) analysis of clinical images. Methods: Magnified (1.75x) PCM images were scanned (sampling rate, 43.75 mu m) and then reduced to original-sized, 25-micron pixel images printed on photothermographic film. Along with corresponding SF images, the phantom images were evaluated subjectively, and the clinical images of 38 patients were subjected to ROC analysis of mass and microcalcification. Results: In the image quality of a phantom, the PCM exceeded the SF. In both mass and microcalcification, the ROC analysis Az values of the PCM clinical images surpassed those of the SF images. Conclusion: The PCM provides better images than the SF. Clinical trials suggest superior detection of both mass and microcalcification by full-field digital PCM over conventional SF mammography.
引用
收藏
页码:385 / 396
页数:12
相关论文
共 50 条
  • [31] Imaging characteristics of a direct conversion full-field digital mammography detector using selenium
    Lee, DL
    Yorker, JG
    Jing, ZX
    Jeromin, LS
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 43 - 47
  • [32] Three-dimensional X-ray fluorescence imaging with confocal full-field X-ray microscope
    Takeuchi, Akihisa
    Terada, Yasuko
    Uesugi, Kentaro
    Suzuki, Yoshio
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 616 (2-3): : 261 - 265
  • [33] Radiation Exposure of Contrast-Enhanced Spectral Mammography Compared With Full-Field Digital Mammography
    Jeukens, Cecile R. L. P. N.
    Lalji, Ulrich C.
    Meijer, Eduard
    Bakija, Betina
    Theunissen, Robin
    Wildberger, Joachim E.
    Lobbes, Marc B. I.
    [J]. INVESTIGATIVE RADIOLOGY, 2014, 49 (10) : 659 - 665
  • [34] Confocal full-field X-ray microscope for novel three-dimensional X-ray imaging
    Takeuchi, Akihisa
    Terada, Yasuko
    Suzuki, Yoshio
    Uesugi, Kentaro
    Aoki, Sadao
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 : 616 - 621
  • [35] An x-ray attenuation approach to breast density for full field digital mammography
    Uyamker, B.
    Rajapakshe, R.
    Baxter, P.
    [J]. MEDICAL PHYSICS, 2009, 36 (09) : 4305 - 4306
  • [36] Modeling the x-ray energy characteristics of DQE for full field digital mammography
    Tkaczyk, JE
    LeBlanc, J
    Nevin, R
    Kautz, G
    Albagli, D
    Sandrik, J
    Granfors, P
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 570 - 581
  • [37] Propagation-based phase-contrast imaging method for full-field X-ray microscopy using advanced Kirkpatrick-Baez mirrors
    Tanaka, Yuto
    Yamada, Jumpei
    Inoue, Takato
    Kimura, Takashi
    Shimura, Mari
    Kohmura, Yoshiki
    Yabashi, Makina
    Ishikawa, Tetsuya
    Yamauchi, Kazuto
    Matsuyama, Satoshi
    [J]. OPTICS EXPRESS, 2023, 31 (16) : 26135 - 26144
  • [38] Bone Cartilage Imaging with X-ray Interferometry using a Practical X-ray Tube
    Kido, Kazuhiro
    Makifuchi, Chiho
    Kiyohara, Junko
    Itou, Tsukasa
    Honda, Chika
    Momose, Atsushi
    [J]. MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [39] Nanoscale dark-field imaging in full-field transmission X-ray microscopy
    Wirtensohn, Sami
    Qi, Peng
    David, Christian
    Herzen, Julia
    Greving, Imke
    Flenner, Silja
    [J]. OPTICA, 2024, 11 (06): : 852 - 859
  • [40] Full-field x-ray fluorescence imaging using a Fresnel zone plate coded aperture
    Soltau, Jakob
    Meyer, Paul
    Hartmann, Robert
    Strueder, Lothar
    Soltau, Heike
    Salditt, Tim
    [J]. OPTICA, 2023, 10 (01): : 127 - 133