A lateral flow-based portable platform for determination of reproductive status of cattle

被引:7
|
作者
Masello, M. [1 ]
Lu, Z. [2 ]
Erickson, D. [2 ]
Gavalchin, J. [1 ]
Giordano, J. O. [1 ]
机构
[1] Cornell Univ, Dept Anim Sci, Ithaca, NY 14853 USA
[2] Cornell Univ, Sibley Sch Mech & Aerosp Engn, Ithaca, NY 14853 USA
基金
美国食品与农业研究所;
关键词
lateral flow immunoassay; progesterone concentration determination; reproductive status; cattle; TIMED ARTIFICIAL-INSEMINATION; FUNCTIONAL CORPUS-LUTEUM; DAIRY-COWS; ENZYME-IMMUNOASSAY; PROGESTERONE; PROSTAGLANDIN-F2-ALPHA; RESYNCHRONIZATION; NONPREGNANCY; FERTILITY; MANAGEMENT;
D O I
10.3168/jds.2019-17517
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Our objective was to develop and validate a tool integrating a disposable fluorescence-based lateral flow immunoassay (LFIA) coupled with a portable imaging device for estimating circulating plasma concentrations of progesterone (P4). First, we developed and optimized a competitive LFIA test strip to measure P4 in bovine plasma. The LFIA design included a sample pad, a conjugate pad that stores R-phycoerythrin-antiP4 conjugates, a glass-fiber spacer pad, a nitrocellulose membrane with printed test and control lines, and a cellulose-fiber absorbent pad. To perform a test, 20 mu L of plasma and 50 mu L of running buffer were added on the sample pad. After 3 min, 45 mu L of running buffer was added to initiate sample flow. After allowing 15 min to stabilize the colorimetric signal, strips were introduced in an LFIA portable reader wirelessly linked to a laptop to determine P4 concentration based on test-to-control-line signal (T/C ratio). In a series of experiments (n = 6), the ability of the LFIA to differentiate plasma samples with >= 1 or <1 ng/mL of P4 was evaluated. For each experiment, a calibration curve was constructed using plasma with known concentrations of P4 (0.1 to 3.7 ng/mL; n = 5). The resulting linear equation was then used to determine a T/C ratio cutoff to differentiate samples with >= 1 or <1 ng/mL of P4. In addition, to evaluate the ability of the platform to assign samples to P4 concentration groups without a calibration curve for individual batches, we performed a receiver operating characteristic analysis to identify a single cutoff value for T/C ratio that could potentially be used for all batches. Overall, calibration curves showed a linear relationship between T/C ratio and P4 levels (mean coefficient of determination = 0.74; range 0.42 to 0.99). Next, plasma samples from lactating dairy cows (n = 58) were tested in triplicate to determine the ability of the LFIA system to differentiate plasma samples with >= 1 or <1 ng/mL of P4 using a RIA for P4 as reference test. Overall, the LFIA assay correctly classified 90% of the samples, with 97% sensitivity, 83% specificity, 85% positive predictive value, and 96% negative predictive value. Agreement between the tests was substantial (kappa = 0.79; 95% confidence interval 0.64 to 0.95). When using a single cutoff value for T/C ratio selected by receiver operating characteristic analysis, sensitivity and specificity to determine CL presence were 97 (95% confidence interval 82 to 99) and 79% (95% confidence interval 60 to 92), respectively. These data suggest that the developed portable LFIA system can accurately differentiate plasma samples with >= 1 or <1 ng/mL of P4.
引用
收藏
页码:4743 / 4753
页数:11
相关论文
共 50 条
  • [41] Novel Lateral Flow-Based Assay for Simple and Visual Detection of SARS-CoV-2 Mutations
    Gomez-Martinez, Julien
    Henry, Steven
    Tuaillon, Edouard
    van de Perre, Philippe
    Fournier-Wirth, Chantal
    Foulongne, Vincent
    Bres, Jean-Charles
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2022, 12
  • [42] A plasmonic thermal sensing based portable device for lateral flow assay detection and quantification
    Qu, Zhuo
    Wang, Kan
    Alfranca, Gabriel
    de la Fuente, Jesus M.
    Cui, Daxiang
    NANOSCALE RESEARCH LETTERS, 2020, 15 (01):
  • [43] A plasmonic thermal sensing based portable device for lateral flow assay detection and quantification
    Zhuo Qu
    Kan Wang
    Gabriel Alfranca
    Jesús M. de la Fuente
    Daxiang Cui
    Nanoscale Research Letters, 2020, 15
  • [44] Study for Rapid Determination of Tetrodotoxin Based on Lateral Flow Immunoassay
    Chen, Jun
    Zhao, Jing
    Tao, Ning-Ping
    Cong, Jian
    PROCEEDINGS OF THE 2ND ANNUAL INTERNATIONAL CONFERENCE ON ADVANCED MATERIAL ENGINEERING (AME 2016), 2016, 85 : 1305 - 1314
  • [45] M-flow: a Flow-based Music Creation Platform Improves Underrepresented Children's Attitudes toward Computer Programming
    Song, Yukyeong
    Xing, Wanli
    Barron, Alec
    Oh, Hyunju
    Li, Chenglu
    Minces, Victor
    22ND ANNUAL ACM INTERACTION DESIGN AND CHILDREN CONFERENCE, IDC 2023: Rediscovering Childhood, 2023, : 233 - 238
  • [46] A flow-based enzyme-linked immunosorbent assay on a polydimethylsiloxane microchip for the rapid determination of immunoglobulin A
    Nakajima, Hizuru
    Yagi, Maiko
    Kudo, Yuki
    Nakagama, Tatsuro
    Shimosaka, Takuya
    Uchiyama, Katsurr
    TALANTA, 2006, 70 (01) : 122 - 127
  • [47] A flow-based procedure with solenoid micro-pumps for the spectrophotometric determination of uric acid in urine
    Rocha, Diogo L.
    Rocha, Fabio R. P.
    MICROCHEMICAL JOURNAL, 2010, 94 (01) : 53 - 59
  • [48] Flow-based titration with a colorimetric detection box using a smartphone for the determination of titratable acidity in coffee
    Somnam, Sarawut
    Kanna, Miki
    SCIENCEASIA, 2020, 46 (01): : 52 - 58
  • [49] A chemiluminescence flow-based procedure for determination of carbaryl in natural waters exploiting multicommutation and enzymatic reaction
    Pires, Cherrine K.
    Morales-Rubio, Angel
    de la Guardia, Miguel
    Lima, Josg L. F. C.
    Zagatto, Elias A. G.
    Reis, Boaventura F.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2007, 18 (03) : 519 - 525
  • [50] Analytical challenges and advantages of using flow-based methodologies for ammonia determination In estuarine and marine waters
    Sraj, Lenka O'Connor
    Almeida, M. Ines G. S.
    Swearer, Stephen E.
    Kolev, Spas D.
    McKelvie, Ian D.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 59 : 83 - 92