A lateral flow-based portable platform for determination of reproductive status of cattle

被引:7
|
作者
Masello, M. [1 ]
Lu, Z. [2 ]
Erickson, D. [2 ]
Gavalchin, J. [1 ]
Giordano, J. O. [1 ]
机构
[1] Cornell Univ, Dept Anim Sci, Ithaca, NY 14853 USA
[2] Cornell Univ, Sibley Sch Mech & Aerosp Engn, Ithaca, NY 14853 USA
基金
美国食品与农业研究所;
关键词
lateral flow immunoassay; progesterone concentration determination; reproductive status; cattle; TIMED ARTIFICIAL-INSEMINATION; FUNCTIONAL CORPUS-LUTEUM; DAIRY-COWS; ENZYME-IMMUNOASSAY; PROGESTERONE; PROSTAGLANDIN-F2-ALPHA; RESYNCHRONIZATION; NONPREGNANCY; FERTILITY; MANAGEMENT;
D O I
10.3168/jds.2019-17517
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Our objective was to develop and validate a tool integrating a disposable fluorescence-based lateral flow immunoassay (LFIA) coupled with a portable imaging device for estimating circulating plasma concentrations of progesterone (P4). First, we developed and optimized a competitive LFIA test strip to measure P4 in bovine plasma. The LFIA design included a sample pad, a conjugate pad that stores R-phycoerythrin-antiP4 conjugates, a glass-fiber spacer pad, a nitrocellulose membrane with printed test and control lines, and a cellulose-fiber absorbent pad. To perform a test, 20 mu L of plasma and 50 mu L of running buffer were added on the sample pad. After 3 min, 45 mu L of running buffer was added to initiate sample flow. After allowing 15 min to stabilize the colorimetric signal, strips were introduced in an LFIA portable reader wirelessly linked to a laptop to determine P4 concentration based on test-to-control-line signal (T/C ratio). In a series of experiments (n = 6), the ability of the LFIA to differentiate plasma samples with >= 1 or <1 ng/mL of P4 was evaluated. For each experiment, a calibration curve was constructed using plasma with known concentrations of P4 (0.1 to 3.7 ng/mL; n = 5). The resulting linear equation was then used to determine a T/C ratio cutoff to differentiate samples with >= 1 or <1 ng/mL of P4. In addition, to evaluate the ability of the platform to assign samples to P4 concentration groups without a calibration curve for individual batches, we performed a receiver operating characteristic analysis to identify a single cutoff value for T/C ratio that could potentially be used for all batches. Overall, calibration curves showed a linear relationship between T/C ratio and P4 levels (mean coefficient of determination = 0.74; range 0.42 to 0.99). Next, plasma samples from lactating dairy cows (n = 58) were tested in triplicate to determine the ability of the LFIA system to differentiate plasma samples with >= 1 or <1 ng/mL of P4 using a RIA for P4 as reference test. Overall, the LFIA assay correctly classified 90% of the samples, with 97% sensitivity, 83% specificity, 85% positive predictive value, and 96% negative predictive value. Agreement between the tests was substantial (kappa = 0.79; 95% confidence interval 0.64 to 0.95). When using a single cutoff value for T/C ratio selected by receiver operating characteristic analysis, sensitivity and specificity to determine CL presence were 97 (95% confidence interval 82 to 99) and 79% (95% confidence interval 60 to 92), respectively. These data suggest that the developed portable LFIA system can accurately differentiate plasma samples with >= 1 or <1 ng/mL of P4.
引用
收藏
页码:4743 / 4753
页数:11
相关论文
共 50 条
  • [31] Recent advances in flow-based sample pretreatment for the determination of metal species by atomic spectrometry
    Yu YongLiang
    Wang JianHua
    CHINESE SCIENCE BULLETIN, 2013, 58 (17): : 1992 - 2002
  • [32] A multicommuted flow-based system for hydrogen peroxide determination by chemiluminescence detection using a photodiode
    Leite, Oldair D.
    Fatibello-Filho, Orlando
    Vieira, Heberth J.
    Rocha, Fabio R. P.
    de Miranda Cury, Newton Sa
    ANALYTICAL LETTERS, 2007, 40 (16-18) : 3148 - 3157
  • [33] Recent advances in flow-based sample pretreatment for the determination of metal species by atomic spectrometry
    YU YongLiang
    WANG JianHua
    Science Bulletin, 2013, (17) : 1992 - 2002
  • [34] Development of a Spectrophotometric Flow-Based System for the Determination of Total Polyphenol Content in Legume Flours
    Osorio, Jazmin
    Ribas, Tania C. F.
    Vasconcelos, Marta W.
    Rangel, Antonio O. S. S.
    PHYTOCHEMICAL ANALYSIS, 2025, 36 (02) : 430 - 437
  • [35] PAIRFLOW: ENHANCING PORTABLE CHEST X-RAY BY FLOW-BASED DEFORMATION FOR COVID-19 DIAGNOSING
    Ngan Le
    Sorensen, James
    Toan Duc Bui
    Choudhary, Arabinda
    Khoa Luu
    Hien Nguyen
    2021 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2021, : 215 - 219
  • [36] Flow-Based Parameter Determination in Large-Scale Electric Power Transmission Systems
    Matthes, Bjoern
    Spieker, Christopher
    Rehtanz, Christian
    2017 IEEE MANCHESTER POWERTECH, 2017,
  • [37] Lateral Flow-Based Skin Patch for Rapid Detection of Protein Biomarkers in Human Dermal Interstitial Fluid
    Wilkirson, Elizabeth C.
    Li, Danika
    Lillehoj, Peter B.
    ACS SENSORS, 2024, 9 (11): : 5792 - 5801
  • [38] Inhibition of Recombinase Polymerase Amplification by Background DNA: A Lateral Flow-Based Method for Enriching Target DNA
    Rohrman, Brittany
    Richards-Kortum, Rebecca
    ANALYTICAL CHEMISTRY, 2015, 87 (03) : 1963 - 1967
  • [39] An improved procedure for flow-based turbidimetric sulphate determination based on a liquid core waveguide and pulsed flows
    Melchert, Wanessa R.
    Rocha, Fabio R. P.
    ANALYTICA CHIMICA ACTA, 2008, 616 (01) : 56 - 62
  • [40] Insulin nucleation kinetics in an oscillatory flow-based platform: Protein crystallization as a highly reproducible separation process
    Ferreira, Joana
    Araujo, Sofia
    Ferreira, Antonio
    Teixeira, Jose
    de Campos, Joao Moreira
    Rocha, Fernando
    Castro, Filipa
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2024, 203 : 453 - 466