A lateral flow-based portable platform for determination of reproductive status of cattle

被引:7
|
作者
Masello, M. [1 ]
Lu, Z. [2 ]
Erickson, D. [2 ]
Gavalchin, J. [1 ]
Giordano, J. O. [1 ]
机构
[1] Cornell Univ, Dept Anim Sci, Ithaca, NY 14853 USA
[2] Cornell Univ, Sibley Sch Mech & Aerosp Engn, Ithaca, NY 14853 USA
基金
美国食品与农业研究所;
关键词
lateral flow immunoassay; progesterone concentration determination; reproductive status; cattle; TIMED ARTIFICIAL-INSEMINATION; FUNCTIONAL CORPUS-LUTEUM; DAIRY-COWS; ENZYME-IMMUNOASSAY; PROGESTERONE; PROSTAGLANDIN-F2-ALPHA; RESYNCHRONIZATION; NONPREGNANCY; FERTILITY; MANAGEMENT;
D O I
10.3168/jds.2019-17517
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Our objective was to develop and validate a tool integrating a disposable fluorescence-based lateral flow immunoassay (LFIA) coupled with a portable imaging device for estimating circulating plasma concentrations of progesterone (P4). First, we developed and optimized a competitive LFIA test strip to measure P4 in bovine plasma. The LFIA design included a sample pad, a conjugate pad that stores R-phycoerythrin-antiP4 conjugates, a glass-fiber spacer pad, a nitrocellulose membrane with printed test and control lines, and a cellulose-fiber absorbent pad. To perform a test, 20 mu L of plasma and 50 mu L of running buffer were added on the sample pad. After 3 min, 45 mu L of running buffer was added to initiate sample flow. After allowing 15 min to stabilize the colorimetric signal, strips were introduced in an LFIA portable reader wirelessly linked to a laptop to determine P4 concentration based on test-to-control-line signal (T/C ratio). In a series of experiments (n = 6), the ability of the LFIA to differentiate plasma samples with >= 1 or <1 ng/mL of P4 was evaluated. For each experiment, a calibration curve was constructed using plasma with known concentrations of P4 (0.1 to 3.7 ng/mL; n = 5). The resulting linear equation was then used to determine a T/C ratio cutoff to differentiate samples with >= 1 or <1 ng/mL of P4. In addition, to evaluate the ability of the platform to assign samples to P4 concentration groups without a calibration curve for individual batches, we performed a receiver operating characteristic analysis to identify a single cutoff value for T/C ratio that could potentially be used for all batches. Overall, calibration curves showed a linear relationship between T/C ratio and P4 levels (mean coefficient of determination = 0.74; range 0.42 to 0.99). Next, plasma samples from lactating dairy cows (n = 58) were tested in triplicate to determine the ability of the LFIA system to differentiate plasma samples with >= 1 or <1 ng/mL of P4 using a RIA for P4 as reference test. Overall, the LFIA assay correctly classified 90% of the samples, with 97% sensitivity, 83% specificity, 85% positive predictive value, and 96% negative predictive value. Agreement between the tests was substantial (kappa = 0.79; 95% confidence interval 0.64 to 0.95). When using a single cutoff value for T/C ratio selected by receiver operating characteristic analysis, sensitivity and specificity to determine CL presence were 97 (95% confidence interval 82 to 99) and 79% (95% confidence interval 60 to 92), respectively. These data suggest that the developed portable LFIA system can accurately differentiate plasma samples with >= 1 or <1 ng/mL of P4.
引用
收藏
页码:4743 / 4753
页数:11
相关论文
共 50 条
  • [21] A novel automated flow-based biosensor for the determination of organophosphate pesticides in milk
    Mishra, Rupesh K.
    Dominguez, Rocio B.
    Bhand, Sunil
    Munoz, Roberto
    Marty, Jean-Louis
    BIOSENSORS & BIOELECTRONICS, 2012, 32 (01): : 56 - 61
  • [22] Flow-Based Chemiluminescence Microarrays as Screening Platform for Affinity Binders to Capture and Elute Bacteria
    Neumair, Julia
    Elsner, Martin
    Seidel, Michael
    SENSORS, 2022, 22 (22)
  • [23] A multisyringe flow-based system for kinetic-catalytic determination of cobalt(II)
    Chaparro, Laura
    Ferrer, Laura
    Leal, Luz
    Cerda, Victor
    TALANTA, 2015, 133 : 94 - 99
  • [24] A Robust Flow-Based System for the Spectrophotometric Determination of Cr(VI) in Recreational Waters
    Ribas, Tania C. F.
    Mesquita, Raquel B. R.
    Machado, Ana
    Miranda, Joana L. A.
    Marshall, Graham
    Bordalo, Adriano
    Rangel, Antonio O. S. S.
    MOLECULES, 2022, 27 (07):
  • [25] Flow-based determination of total mercury in waters by flameless atomic absorption spectrometry
    Ferreira, Jose Roberto
    Bendassoli, Jose Albertino
    Pessenda, Luiz Carlos Ruiz
    Krug, Francisco Jose
    Zagatto, Elias Ayres Guidetti
    MUNDO DA SAUDE, 2024, 48
  • [26] Determination of Minoxidil by Bleaching the Permanganate Carrier Solution in a Flow-Based Spectrophotometric System
    de Sousa, Rogerio Adelino
    Semaan, Felipe Silva
    Cervini, Priscila
    Gomes Cavalheiro, Eder Tadeu
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 349 - 359
  • [27] Lateral flow microarrays: a novel platform for rapid nucleic acid detection based on miniaturized lateral flow chromatography
    Carter, Darren J.
    Cary, R. Bruce
    NUCLEIC ACIDS RESEARCH, 2007, 35 (10)
  • [28] Acoustic Flow-Based Control of a Mobile Platform Using a 3D Sonar Sensor
    Steckel, Jan
    Peremans, Herbert
    IEEE SENSORS JOURNAL, 2017, 17 (10) : 3131 - 3141
  • [29] Lateral flow assay for cattle age determination: Implications for diagnosing bovine spongiform encephalopathy
    Jeong, Bongjin
    Kim, Soo Hyeon
    Yang, Kyeong Eun
    Kim, Sojeong
    Choi, Jung-Seok
    Choi, Jong-Soon
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 424
  • [30] Reliable Sensing Platform for Plasmonic Enzyme-Linked Immunosorbent Assays Based on Automatic Flow-Based Methodology
    Kaewwonglom, Natcha
    Oliver, Miquel
    Cocovi-Solberg, David J.
    Zirngibl, Katharina
    Knopp, Dietmar
    Jakmunee, Jaroon
    Miro, Manuel
    ANALYTICAL CHEMISTRY, 2019, 91 (20) : 13260 - 13267