COMPARISON AND EXPERIMENTAL VALIDATION OF TURBULENCE MODELS FOR AN AXIAL FLOW BLOOD PUMP

被引:10
|
作者
Wang, Shuai [1 ]
Tan, Jianping [1 ]
Yu, Zheqin [1 ]
机构
[1] Cent S Univ, Coll Mech & Elect Engn, Changsha 410083, Hunan, Peoples R China
关键词
Blood pump; CFD simulation; turbulence model; PIV experiment; flow field distribution; VENTRICULAR ASSIST DEVICES; SHEAR-STRESS; PERFORMANCE; DAMAGE; FIELD;
D O I
10.1142/S0219519419400633
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Computational fluid dynamics (CFD) has become an essential tool for designing and optimizing the structure of blood pumps. However, it is still questionable which turbulence model can better obtain the flow information for axial flow blood pump. In this study, the axial flow blood pump was used as the object, and the influence of the common turbulence models on simulation was compared. Six turbulence models (standard k-epsilon model, RNG k-epsilon model, standard k-omega model, SST k-omega model, Spalart-Allmaras model, SSG Reynolds stress model) were used to simulate the pressure difference and velocity field of the pump. In parallel, we designed a novel drive system of the axial flow blood pump, which allowed the camera to capture the internal flow field. Then we measured the flow field in the impeller region based on particle image velocimetry (PIV). Through the comparison of experiments and simulation results, the average errors of velocity field obtained by the above models are 30.97%, 19.40%, 24.25%, 15.28%, 28.51%, 23.00%, respectively. Since the SST k-omega model has the smallest error, and the streamline is consistent with the experimental results, it is recommended to use SST k-omega model for numerical analysis of the axial flow blood pump.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] In vitro performance of a centrifugal, a mixed flow, and an axial flow blood pump
    Araki, K
    Anai, H
    Oshikawa, M
    Nakamura, K
    Onitsuka, T
    ARTIFICIAL ORGANS, 1998, 22 (05) : 366 - 370
  • [32] Development of miniaturized mass flow meter for an axial flow blood pump
    Kosaka, Ryo
    Maruyama, Osamu
    Nishida, Masahiro
    Yamane, Takashi
    ARTIFICIAL ORGANS, 2007, 31 (05) : 412 - 419
  • [33] Experimental Investigation of Unsteady Flow in a Vertical Shaft Axial Flow Pump
    Canbaz, Ozgur
    Yucel, Nuri
    Albayrak, Kahraman
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2023, 26 (02): : 1025 - 1034
  • [34] UNSTEADY FLOW ANALYSIS AND EXPERIMENTAL INVESTIGATION OF AXIAL-FLOW PUMP
    Zhang De-sheng
    Shi Wei-dong
    Chen Bin
    Guan Xing-fan
    JOURNAL OF HYDRODYNAMICS, 2010, 22 (01) : 35 - 43
  • [35] UNSTEADY FLOW ANALYSIS AND EXPERIMENTAL INVESTIGATION OF AXIAL-FLOW PUMP
    ZHANG De-sheng
    JournalofHydrodynamics, 2010, 22 (01) : 35 - 43
  • [36] Numerical simulation and experimental study on flow field in an axial flow pump
    Huang, Huan-Ming
    Gao, Hong
    Du, Zhao-Hui
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2009, 43 (01): : 124 - 128
  • [37] Unsteady Flow Analysis and Experimental Investigation of Axial-Flow Pump
    De-sheng Zhang
    Wei-dong Shi
    Bin Chen
    Xing-fan Guan
    Journal of Hydrodynamics, 2010, 22 : 35 - 43
  • [38] EXPERIMENTAL STUDY ON CAVITATING FLOW IN IMPELLER OF AXIAL-FLOW PUMP
    Li Zhong
    Yang Minguan
    Kang Can
    Gao Bo
    Ji Kai
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE 2011, VOL 1, PTS A-D, 2012, : 381 - 386
  • [39] Axial type self-bearing motor for axial flow blood pump
    Okada, Y
    Masuzawa, T
    Matsuda, KI
    Ohmori, K
    Yamane, T
    Konishi, Y
    Fukahori, S
    Ueno, S
    Kim, SJ
    ARTIFICIAL ORGANS, 2003, 27 (10) : 887 - 891
  • [40] Relationship between pump speed design and hemolysis in an axial flow blood pump
    Anai, H
    Wakisaka, Y
    Nakatani, T
    Taenaka, Y
    Takano, H
    Hadama, T
    ARTIFICIAL ORGANS, 1996, 20 (06) : 564 - 567